Pitco Frialator L20-378 operation manual Installation GAS Connection, Quick Disconnect Connection

Page 8

INSTALLATION

1.4.1.GAS CONNECTION

Your gas appliance will give you peak performance when the gas supply line is of sufficient size to provide the correct gas pressure. The gas line must be installed to meet the local building codes or National Fuel Gas Code ANSI Z223.1 Latest Edition. In Canada, install the appliance in accordance with CAN/CGA-B149.1 or .2 and local codes. In Australia, install the appliance in accordance with AS/NZS 5601. Gas line sizing requirements can be determined by your local gas company or, in North America, by referring to the National Fuel Gas Code, Appendix C, Table C-4 (for natural gas) and Table C-16 (for propane). The gas line needs to be large enough to supply the necessary amount of fuel to all appliances without losing pressure to any appliance. A properly sized and installed gas line will deliver a supply pressure between 7.0” W.C. (17.4mbars, 1.74kPa) and 10.0”W.C. (24.9mbars, 2.49kPa) natural gas or between 11.0”W.C. (27.4mbars, 2.74kPa) and 13.0” W.C.

(32.4mbars, 3.25kPa) for propane to all appliances connected to the supply line, operating simultaneously at full demand. The pressure at the gas valve shall not exceed ½ PSI.

The gas supply connection to this appliance is located in the rear of the appliance approximately 10-1/2” (26.7 cm) from the floor of the appliance when legs are used.

Each appliance is equipped to operate on one certain fuel type. The type of fuel with which the appliance is intended to operate is stamped on the data plate, which is attached to the inside of the door.

WARNING

NEVER supply the appliance with a gas other than the one that is indicated on the data plate. Using the incorrect gas type will cause improper operation and could result in serious injury or death. If you need to convert the appliance to another type of fuel, contact the dealer you purchased it from.

NOTICE

NEVER use an adapter to make a smaller gas supply line fit the appliance connection. This may not allow proper gas flow for optimum burner operation, resulting in poor performance and improper operation.

1.4.2.QUICK DISCONNECT CONNECTION

In North America, gas appliances equipped with casters must be installed with connectors that comply with the Standard for Connectors for Movable Gas Appliances, ANSI Z21.69.CSA 6.16 Latest Edition. This connection should include a quick disconnect device that complies with the Standard for Quick Disconnect Devices for Use With Gas Fuel Appliances ANSI Z21.41.CSA 6.9 Latest Edition. In Australia, an appliance equipped with casters and a flexible gas line must be connected to the gas supply with a quick disconnect device that complies with AS 4627 and a restraining cable. The restraining cable must not exceed 80% of the length of the flexible gas line. The restraining device should be attached to the appliance at the back panel.

1.4.3.FUEL SUPPLY LINE LEAK AND PRESSURE TESTING

The fuel supply system must be tested before the appliance is used. If the fuel line is going to be tested at a pressure greater than ½ PISG (3.45 kPa, 34.5 mbar), insure that that appliance is disconnected from the fuel line. If the fuel line is to be tested at a pressure equal to or less than ½ PSIG (3.45 kPa, 34.5 mbar), the appliance can be connected during the test, but the unit’s gas valve must be shut. Test all gas line connections for leaks with a solution of soap and water when pressure applied.

1.4.4.INSTALLATION SETUP

The installation of this appliance MUST conform to local codes. In the absence of local codes in North America, the installation must conform with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 or the Natural Gas and Propane Installation Code CSA B149.1 as applicable. In Australia, the appliance must installed in compliance with AS/NZS 5601 (current revision).

8

L20-378 rev. 0 (9/12)

Image 8
Contents English To the PURCHASER, Owner and Store Manager Installation CE GAS Table not Applicable to ALL ModelsBoil OUT Procedure Temperature Check ANNUAL/PERIODIC Preventative Maintenance and InspectionBasket Lift Operation Additional Controller FunctionsTroubleshooting Installation Installation ClearancesHeat Deflector Installation if Equipped Checking Your NEW ApplianceLEG/CASTER Installation and Leveling Quick Disconnect Connection Installation GAS ConnectionInstallation Setup Installation CE GAS Table not Applicable to ALL Models SGM20 G20 Overall Dimensions and Weights US and Canada Ventilation and Fire Safety Systems Electrical ConnectionsInitial Adjustments InspectionON/OFF Filling the ApplianceDrain Valve Closed OFF Initial Cleaning Preventative Maintenance Operational FeaturesPreventative Maintenance Basic Operational Features Cook Tank Front PanelFilling the Cooker Tank Filling the Tank with Liquid ShorteningTemperatura DELL’OLIO OIL TemperatureAppliance Start UP Preventative Maintenance Θερμοκρασια Λαδιου Timer OperationCooking SpinfreshtmStandby Mode Additional Controller FunctionsCooking Tips Appliance ShutdownFiltering with a Filter Drawer if Equipped Preventative Maintenance Complete ShutdownDaily Preventative Maintenance Preventative Maintenance Flush Hose Operation if Equipped Preventative Maintenance Preventative Maintenance Filter Cleaning if Equipped Weekly Preventative MaintenanceMonthly Preventative Maintenance Boil OUT ProcedureANNUAL/PERIODIC Preventative Maintenance and Inspection Mechanical Inspection Ventilation HoodTroubleshooting Power FailureHigh Temperature Limit Switch Drain Valve Interlock & Float Switch not on ALL ModelsTroubleshooting Troubleshooting Charts Fryer Troubleshooting ChartFilter Troubleshooting Chart if Equipped DrainingDisplay Explanation Action Troubleshooting L20-378 rev 9/12

L20-378 specifications

The Pitco Frialator L20-378 is a highly regarded piece of commercial kitchen equipment, specifically designed for high-volume frying operations. Renowned for its efficiency and durability, the L20-378 meets the demands of busy restaurants, fast food chains, and catering operations that require consistent performance and outstanding results.

One of the standout features of the L20-378 is its impressive fry tank capacity. With a 40-pound oil capacity, it can handle a significant amount of product at once, allowing for simultaneous frying and the ability to serve large volumes quickly. This efficiency not only enhances productivity but also helps streamline kitchen operations during peak hours.

The L20-378 utilizes advanced heating technology known as "Heat exchanger" design. This technology maximizes heat transfer from the burners to the oil, ensuring that food cooks evenly and consistently. As a result, operators benefit from faster cooking times and exceptional product quality, with crispy exteriors and tender interiors.

Moreover, the unit's durable construction is a key characteristic. Built with stainless steel, the L20-378 is not only resistant to corrosion but also easy to clean and maintain. This durability extends the life of the fryer, making it a valuable investment for any kitchen. The fryer also features a convenient drain valve, enabling easy oil changing and maintenance, which is crucial for keeping the frying environment clean.

The L20-378 is equipped with user-friendly controls that allow for precise temperature settings and consistent frying results. This ease of use ensures that even less experienced staff can operate the fryer efficiently, minimizing the risk of mistakes during crucial cooking processes.

Another important aspect of the Pitco Frialator L20-378 is its safety features. These include built-in automatic temperature controls and high-limit protection to prevent overheating, contributing to a safer working environment. Additionally, the fryer is designed with a cool zone that helps catch food particles, reducing the likelihood of oil breakdown and extending the oil life.

In summary, the Pitco Frialator L20-378 is an exceptional fryer that combines large capacity, advanced heating technology, durable construction, and user-friendly controls. Its focus on efficiency and safety makes it a preferred choice for busy kitchens that demand reliable frying solutions capable of producing high-quality food consistently.