TROUBLESHOOTING
TROUBLESHOOTING | MODEL |
Figure 15
Controller Check (EZ-5 only)
C98
1.Disconnect power at circuit breaker.
2.Remove control panel, but leave plugged in.
3.Disconnect wire C98 from controller.
4.Reconnect power.
5.Use a spacer to hold door switch in closed position. Contactor should actuate and then deactuate in less than 60 seconds.
6.If contactor fails to actuate (or actuates but fails to deactuate), replace controller.
7.With spacer still in place and door open, momentarily reconnect wire C98 and then disconnect.
8.Controller should actuate, then deactuate 10 seconds after C98 is disconnected.
9.If contactor fails to actuate (or actuates but fails to deactuate), replace controller.
PAGE 32 | OPERATOR’S MANUAL 1178387 REV 2 |