Roland MMP-2 owner manual Specifications

Page 53

Specifications

Analog Input

Connector:

XLR-3-31 type (balanced)

1/4 inch TRS phone type (balanced) Input Impedance:

40k Ω Phantom Power:

DC 48 V and 7m A when the output is shorted PAD:

20 dB pad Maximum Input Level:

+2 dBu (PAD off)

+22 dBu (PAD on)

Nominal Input Level: -64 dBu – +4 dBu

Equivalent Input Noise: -132 dBu (IHF-A typ.)

Analog Output

Connector:

XLR-3-32 type (balanced)

Output Impedance:

600

Recommended Load Impedance: 1k Ω or greater

Nominal Output Level: -16 dBu / +4 dBu

Signal-to-Noise Ratio: 105 dB typ.

Digital Input

Connector: RCA for S/PDIF

Impedance: 75 Ω

Digital Output

Connector: XLR for AES/EBU, RCA for S/PDIF

Impedance: 110 Ω for AES/EBU, 75 Ω for S/PDIF

Signal Processing

A/D Conversion: 24-bit, 64 times oversampling

D/A Conversion: 24-bit, 128 times oversampling

Sample Rate

96.0kHz, 88.2k Hz, 48.0k Hz, 44.1k Hz

Frequency Response

96.0k Hz: 20 Hz – 40k Hz (+0.1 / -3.0 dB)

88.2k Hz: 20 Hz – 40k Hz (+0.1 / -3.0 dB)

48.0k Hz: 20 Hz – 20k Hz (+0.1 / -0.5 dB)

44.1k Hz: 20 Hz – 20k Hz (+0.1 / -0.5 dB)

Microphone Modeling

Reference Microphone:

DR-20, Small Dynamic Microphone,

Head-worn Dynamic Microphone,

Miniature Condenser Microphone, AKG C3000B, Flat Modeling Microphone:

Small Dynamic, Vocal Dynamic, Large Dynamic, Small Condenser, Large Condenser,

Vintage Condenser, Flat

Equalizer

4-Band parametric equalizer Reference Frequency: 20 Hz – 20k Hz Type:

Peaking, Low-Shelving, High-Shelving, Low-Pass,

High-Pass, Low-Pass2, Hi-Pass2, Band-Pass,

Band-Eliminate

GAIN: -15 dB – +15 dB

Compressor

Type: Solid, Tube1, Tube2, Tube3, Tube4

Knee Type: Hard or Soft knee

Other Effects

Expander, Enhancer, De-esser, Pre-amp Modeling

Display

20 characters, 2 lines (back light LCD)

Power Supply

AC 117 V, AC 230 V or AC 240 V

Power Consumption

9 W

Dimension

250 (W) x 165 (D) x 76 (H) mm

9-7/8 (W) x 6-1/2 (D) x 3 (H) inches

Weight

1.8kg

4 lbs

Accessories

Owner’s Manual, CD-ROM, AC Cord, USB Cable

(0 dBu = 0.775 Vrms)

*In the interest of product improvement, the specifications and/or appearance of this unit are subject to change without prior notice.

53

Image 53
Contents Copyright 2002 Roland Corporation Page Using the Unit Safely Contents Settings for Digital Connections Placement Power SupplyMaintenance Additional PrecautionsCopyright Handling CD-ROMsChecking the Included Items Main FeaturesGetting Started Top Panel Top and Rear PanelsRear Panel Pad Sens Function Organization and Signal FlowEqualizer DynamicsGetting Ready to Switch on the Power Set Up and Basic OperationsConnecting the Power Source Making the ConnectionsTurning On the Power Setting the Output LevelConnecting the Input Device Connecting the Output EquipmentGlobal Functions Adjusting the Contrast of the LCD Screen LcdcntPatches Save pressing Enter buttonSaving a Patch Store Patch Resetting Effect Parameters ResetPatch Selection Select Edit Channel Select Edit CH Select MetersInput Dynamics CMP / EXPPeak Indicator Settings for the Analog InputsPhantom Power +48V PadPhase Turning Off the PowerLow-cut Filter LO-CUT Attenuator ATTMic Modeling Using EffectsMic Modeling OFF/ON Model Reference Microphone InputEqualizer Compressor DynamicsGain Gain Filter Type TypeKey In Channel KEY Compressor Type TypeThreshold Thresh Ratio RatioEnhancer/De-esser ExpanderPre-amp Modeling Plug-in EffectHarmonic BrightSampling Clock Source Settings for Digital ConnectionsSampling Frequency Audio Input SourceAnalog Input to Digital Output Examples of UseAnalog Input to Analog Output Copying Settings Between Channels Other FeaturesBackup Patch Channel LinkingInitializing RouteSet up PC setting and Install Use of computer and setupMMP-2 settings Computer settingsWindows Me Use the following procedure to install the MMP-2 driverDeleting the MMP-2 Driver WindowsUse of computer and setup Use the USB cable to connect the MMP-2 and your computer Macintosh / OMS Installing the MMP-2 DriverOMS settings USB connector USB cableUse of computer and setup Macintosh / FreeMIDI FreeMIDI settings About Quick Setup dialog box will appear. Click Continue Functions work in conjunction with computers Backup PatchesIntuitive operation of MMP-2 using MMP-2 editor Symptom Cause Remedy Trouble ShootingAnother patch Resetting Effect Parameters MMP-2 settings pWindows users Trouble Shooting about ComputerMacintosh users Cannot make USB connections correctly MMP-2 does not recover correctly from sleep modeMacintosh hangs up Was the MMP-2 recognized?Transmitted Data Midi ImplementationData Transfer Address Map Algorithm 1 MIC Modeling + Dynamics + Plug INPreamp Status Bulk Data Appendices Midi Implementation Chart Specifications Index SymbolsWindows Memo Memo Information Important Safety Instructions 02897523 ’02-2-E2-21KS About Input Jacks Limitations and Conditions of Condenser Microphone