Using Effects

Bright

This parameter adjusts the brightness of the input sound by changing the high frequency content's balance.

Brightness Frequency (BRT F)

This sets the lower limit of this parameter. The sound components that are of a higher frequency than this parameter will be adjusted. You can set a value from 1.00k Hz to 20.0k Hz.

Brightness Gain (BRT G)

This parameter adjusts the brightness of the signal above the value set with the Brightness Frequency parameter.You can set a value within a range of ±6.0 dB.

Harmonic

This adjusts the color and balance of the sound's harmonics

Harmonic Threshold (HRM TH)

This sets the threshold for the Harmonic Balance control. If the sound level exceeds this level, the harmonics control will function. You can set a value from -24 dB to 0.0 dB.

Harmonic Level (HRM LV)

This sets the value of the harmonic control. You can set a value in 100 steps (from 0 to 100).

Harmonic Color (HRM CL)

This sets the value of the harmonic distortion. You can set a value in 100 steps (from 0 to 100).

Using Effects

25

Image 25
Contents Copyright 2002 Roland Corporation Page Using the Unit Safely Contents Settings for Digital Connections Placement Power SupplyMaintenance Additional PrecautionsCopyright Handling CD-ROMsGetting Started Main FeaturesChecking the Included Items Top Panel Top and Rear PanelsRear Panel Pad Sens Function Organization and Signal FlowEqualizer DynamicsGetting Ready to Switch on the Power Set Up and Basic OperationsConnecting the Power Source Making the ConnectionsTurning On the Power Setting the Output LevelConnecting the Input Device Connecting the Output EquipmentGlobal Functions Adjusting the Contrast of the LCD Screen LcdcntPatches Save pressing Enter buttonPatch Selection Select Resetting Effect Parameters ResetSaving a Patch Store Patch Edit Channel Select Edit CH Select MetersInput Dynamics CMP / EXPPeak Indicator Settings for the Analog InputsPhantom Power +48V PadPhase Turning Off the PowerLow-cut Filter LO-CUT Attenuator ATTMic Modeling Using EffectsMic Modeling OFF/ON Model Reference Microphone InputEqualizer Compressor DynamicsGain Gain Filter Type TypeKey In Channel KEY Compressor Type TypeThreshold Thresh Ratio RatioEnhancer/De-esser ExpanderPre-amp Modeling Plug-in EffectHarmonic BrightSampling Clock Source Settings for Digital ConnectionsSampling Frequency Audio Input SourceAnalog Input to Analog Output Examples of UseAnalog Input to Digital Output Copying Settings Between Channels Other FeaturesBackup Patch Channel LinkingInitializing RouteSet up PC setting and Install Use of computer and setupMMP-2 settings Computer settingsWindows Me Use the following procedure to install the MMP-2 driverDeleting the MMP-2 Driver WindowsUse of computer and setup Use the USB cable to connect the MMP-2 and your computer Macintosh / OMS Installing the MMP-2 DriverOMS settings USB connector USB cableUse of computer and setup Macintosh / FreeMIDI FreeMIDI settings About Quick Setup dialog box will appear. Click Continue Intuitive operation of MMP-2 using MMP-2 editor Backup PatchesFunctions work in conjunction with computers Symptom Cause Remedy Trouble ShootingAnother patch Resetting Effect Parameters MMP-2 settings pWindows users Trouble Shooting about ComputerMacintosh users Cannot make USB connections correctly MMP-2 does not recover correctly from sleep modeMacintosh hangs up Was the MMP-2 recognized?Transmitted Data Midi ImplementationData Transfer Address Map Algorithm 1 MIC Modeling + Dynamics + Plug INPreamp Status Bulk Data Appendices Midi Implementation Chart Specifications Index SymbolsWindows Memo Memo Information Important Safety Instructions 02897523 ’02-2-E2-21KS About Input Jacks Limitations and Conditions of Condenser Microphone