CAUTION

Improper connections to a building’s electrical system can allow electrical current from the generator to backfeed into the utility lines. Such backfeed may electrocute utility company workers or others who contact the lines during a power outage. Consult the utility company or a qualified electrician.

ECAUTION

NImproper connections to a building’s electrical system can allow electrical current from the utility company to backfeed G into the generator. When utility power is restored, the generator may explode, burn, or cause fires in the building’s elec-

Ltrical system.

IIn some areas, generators are required by law to be registered with local utility companies. Check local regulations for S proper registration and use procedures.

H Generator Ground Circuits

McCulloch portable generators have a system ground that connects generator frame components to the ground ter- minals in the AC output receptacles. The system ground is not connected to the AC neutral wire.

Local regulations, codes or laws may require that the ground system be connected to the AC neutral wire. If the gen- erator is tested by a receptacle tester, it will not show the same ground circuit condition as for a home receptacle.

If local regulations, codes, or laws require the system ground to be connected to the AC neutral wire, consult a qual- ified electrician or electrical inspector. Provide them with the electrical wiring diagram in this manual.

 

ATTENTION

 

Des branchements incorrects au système électrique d'un bâtiment peuvent permettre au courant électrique du

 

générateur d’être rétro injecté (backfeed) dans le réseau de service. Un tel backfeed peut électrocuter des ouvriers

 

de la société du réseau ou d'autres qui entrent en contact avec les lignes pendant une coupure de courant. Consultez

F

la société du réseau ou un électricien qualifié.

R

ATTENTION

A

Des branchements incorrects au système électrique d'un bâtiment peuvent permettre au courant électrique du réseau

Nd’être rétro injecté (backfeed) dans le générateur. Quand la puissance réseau est rétablie, le générateur peut explos- C er, brûler, ou causer des incendies dans le système électrique du bâtiment.

A Dans certaines zones, la loi exige que les générateurs soient enregistrés auprès des sociétés de réseau locales.

IVérifiez les réglementations locales.

SPour enregistrement approprié et procédures d'utilisation.

Circuits de terre du générateu

Les groupes électrogènes McCulloch ont une terre système qui relie les composants châssis du générateur aux bornes de terre dans les embases des sorties AC. La terre du système n'est pas connectée au fil AC neutre.

Des réglementations locales, des codes ou des lois peuvent exiger que le système de terre soit connecté au fil AC neutre. Si le générateur est testé par un appareil de contrôle d’embase, il ne montrera pas le même état de circuit de terre qu’une embase domestique.

PRECAUCION

Las conexiones inadecuadas al sistema eléctrico de un edificio pueden ocasionar que la corriente eléctrica del gen- erador se retroalimente a las líneas de servicio. Esta retroalimentación puede electrocutar a trabajadores de la com- pañía de suministro de energía eléctrica o a otros que estén en contacto con las líneas durante un paro de energía. Consulte a la compañía de suministro de energía eléctrica o a un electricista calificado.

EPRECAUCION

SLas conexiones inadecuadas al sistema eléctrico de un edificio pueden ocasionar que la corriente eléctrica de la com-

Ppañía de suministro de energía eléctrica se retroalimente al generador. Cuando la energía de servicio se restablez- A ca, el generador puede explotar, quemarse o producir incendios en el sistema eléctrico del edificio.

Ñ En algunas áreas, se requiere por ley que los generadores estén registrados ante las compañías locales de sumin-

Oistro de energía. Consulte los reglamentos locales para conocer los procedimientos de registro y uso adecuados.

LCircuitos a tierra del generador

Los generadores portátiles McCulloch tienen una tierra de sistema que conecta los componentes de la estructura del generador a las terminales de tierra en los receptáculos de salida de CA. La tierra del sistema no está conectada al cable neutral de CA. Los reglamentos, códigos o leyes locales pueden requerir que el sistema de tierra se conecte al cable neutral de CA. Si el generador se prueba con un probador de receptáculos, no mostrará la misma condición de circuito a tierra que para e receptáculo casero. Si los reglamentos, códigos o leyes locales requieren que la tierra del sistema se conecte al cable neutral de CA, consulte a un electricista calificado o a un inspector eléctrico. Proporciónele el diagrama de cableado eléctrico en este manual.

16

Image 16
Contents Models FG5700A / FG5700AK Please Read Caracteristiques SpecificationsEspecificaciones MARCHE/ARRÊT Apagado Safety Labels Étiquettes DE SécuritéP a Fire and Burn Hazards Peligros DE Incendio Y QuemadurasAssembly Information Montage Informaciones DE Ensamble Handle Assembly Wheel KIT AssemblyAssemblage DU KIT DE Roue Ensamblaje DE LA EmpuñaduraAssemblage DES Pieds LEG AssemblyEnsamblaje DE LAS Patas Huile Moteur Engine OILAceite DEL Motor Fuel Recommendation Recommandation Liees AU CarburantRecomendación DE Combustible Fonctionnement DU Moteur Engine OperationsOperaciones DEL Motor Fuel Switch Generator Operations Precaucion AC Applications AC Operation Page Item / Piece / Parte Vidange DE Moteur Engine OIL ChangeCambio DE Aceite DEL Motor P a Entretien DE LA Bougie Spark Plug ServiceServicio a LA Bujía Entretien DU Disjoncteur AC AC Circuit Breaker ServiceServicio AL Interruptor DE Circuito DE CA Tiempo DE Almace 10-1A Troubleshooting Depannage Deteccion Y Correccion DE Fallas Câblage Elément Puissance de fonctionnement

7096-FG5733 specifications

The McCulloch 7096-FG5733 is a standout performer in the realm of outdoor power equipment, showcasing a blend of innovative technology and user-friendly design. Built to handle a variety of tasks, it is particularly admired for its robust performance and ergonomic features. This model is equipped with a powerful engine, delivering consistent power and efficiency that can tackle mowing, trimming, and various gardening tasks with ease.

One of the most notable features of the McCulloch 7096-FG5733 is its Smart Start technology, which significantly reduces the effort needed to pull-start the engine. This innovation brings convenience, especially for users who may struggle with traditional starting mechanisms. The combined choke and primer system further enhances reliability, ensuring that the engine starts effortlessly in any weather condition.

The unit's cutting performance is equally impressive, thanks to its precision-engineered blade system. The adjustable cutting height allows for customization based on the specific needs of your yard, enabling users to achieve their desired lawn finish. Whether it's a lush, manicured appearance or a more rugged look, the McCulloch 7096-FG5733 delivers versatility and adaptability across various lawn types.

Durability is another key characteristic of the McCulloch brand, and the 7096-FG5733 is no exception. Crafted from high-quality materials, it stands up to the rigors of frequent use, ensuring longevity and resilience. Furthermore, the unit is designed with user comfort in mind, featuring an adjustable handle that promotes better posture and reduces strain during extended operations.

Safety features are also integrated into the design, providing peace of mind while operating the equipment. This includes a blade brake that stops the blade almost instantly, reducing the risk of accidents. The lightweight construction of the device enhances maneuverability, making it easier to navigate tight spaces and uneven terrain.

In conclusion, the McCulloch 7096-FG5733 exemplifies a perfect balance of performance, comfort, and safety. With advanced technologies like Smart Start, adjustable cutting height, and a commitment to durability, it is an excellent choice for both novice gardeners and experienced landscapers looking for reliability and efficiency in their outdoor tasks. Whether tackling a small yard or a large lawn, the McCulloch 7096-FG5733 proves to be a formidable ally in any gardening endeavor.