Multiquip SG1400C3-55748 manual Digital controller

Page 27

digital controller

11

14

13

12

1

2

4 5

3

15

10 9 8 7

6

Figure 9. Digital Controller

Refer to Figure 9 for location of controls and indicators.

1.STATUS LED — Indicates status of the controller. Lights green when the controller is running.

NAVIGATIONS BUTTONS

2.ARROW UP Button — Press button to scroll up through the status menus or programming prompts.

3.ARROW DOWN Button — Press button to scroll down through the status menus or programming prompts.

4.MENU Button — Press button to jump to menu/sub- menu page or escape from any dialog window.

5.ENTER Button — Press button to confirm a value or open a value adjustment within setting dialogs.

CONTEXT BUTTONS

6.MODE Button — Press button to jump to the controller mode window.

7.HISTORY Button — Press button to jump to history screen.

8.ALARM Button — Press button to jump to alarm list

9.GCB (Generator Circuit Breaker) CONTROL Button — Press button to close/open GCB.

10.MCB CONTROL Button — Not functional in this application.

CONTROL BUTTONS

11.START Button — Press button to go idle mode (about an hour) then generator starts. A second press will bypass idle mode and generator goes to full speed immediately.

12.STOP Button — Press button to cool the generator for about 5 minutes then the generator will stop. A second press will bypass cool down and will stop the generator immediately.

NOTICE

START and STOP buttons work in MAN (manual) or SEM (semi-manual) mode only.

13.FAULT RESET Button — Press button to acknowledge faults and alarms (active only in Alarm screen).

14.HORN RESET Button — Press button to deactivate the horn (audible alarm).

15.DISPLAY — Shows menu, measurements, setpoints, alarm list, history, and help/others screens.

NOTICE

For more detailed operating and programming information on the digital controller, refer to the InteliVision 5™ Controller User's Guide.

SG1400c3 studio generator • operation and parts manual — rev. #1 (02/15/12) — page 27

Image 27
Contents Model SG1400C3-55748 Proposition 65 warning Nhtsa Reporting Safety DefectsSpecifications are subject to change without notice Table of ContentsChoose from three easy options Safety Information SaFeTY meSSageSSaFeTY SYmBolS GeneraTor SaFeTY General SaFeTYEngine SaFeTY Restricted. If the air fl ow isIf operating in speed ranges above the maximum allowable From fuel vapors or if fuel is spilled on a hot engine Fuel SaFeTYToWing SaFeTY „ never use fuel as a cleaning agentDeath EleCTriCal SaFeTYGrounding Safety Power Cord/Cable SafetyEnvironmenTal SaFeTY BaTTerY SaFeTYModel Cummins QSB7-G5 SpecificationsDimensions DimensionsTypical Generator Grounding Application InstallationOutdoor Installation Indoor InstallationGenerator Grounding General information Intake Ventilation Door Fuel TankFuel Priming Pump Fuel Water SeparatorInteliVision 5 Digital Controller Page Major Components Generator Major ComponentsDescription Starter Oil Filler CapAlternator Oil FilterLicense Plate Lights Illuminates license plate Basic Trailer ComponentsControl panel Controller Power Switch Provides power to engine controllerCamlok/Voltage Output Panel Camlok/voltage output panelMain Breaker Panel Circuit Breaker panelMCB Control Button Not functional in this application Digital controllerType of Load Single Phase LoadThree Phase Load Load application/generator outputVoltage Selector Switch Generator Output VoltagesGenerator Amperage Fuel Check Inspection/setupRefueling Procedure Lubrication OilOnly use #2 diesel fuel when refueling Remove fuel cap and fill tank FigureWait for fuel to rise in filler neck Operation in Freezing Weather Cleaning the RadiatorAir Cleaner Fan Belt Tension Drive Belt inspection Coolant Antifreeze/summer coolantAlternator Battery Cable InstallationWiring When connecting the battery do the followingAlways have adequate ventilation when operating Before StartingEngine’s exhaust contains harmful emissions Engine will go to idle mode StartupStarting Manual Normal Shutdown Procedure Emergency Shutdown ProcedureClosing the Enclosure DOORs Protective devices Protective devicesEngine Maintenance Schedule MaintenanceAir Filter Air Filter Dust IndicatorCleaning Inside the Fuel Tank General InspectionCheck Oil Level Fuel Tank InspectionReplacing Fuel Filter Air RemovalHydraulic Brake Actuator Manually Adjusting the BrakesTrailer Brakes Hydraulic BrakesWheel Bearings Adjustable ChannelLeaf Suspension Wheel Hub AdjustmentTroubleshooting Generator Troubleshooting generatorTroubleshooting Engine Troubleshooting engineTroubleshooting Intelivision 5 Controller Troubleshooting controllerTrailer guidelines Common CauSeS For loSS oF TrailerTrailer ToWing guidelineS Coupling To THe ToW veHiCle Driving CondiTionSInoperaBle BraKeS, ligHTS or mirrorS Trailer ToWing TipSTrailer vin Tag BraKe ConTroller EleCTriCal ConneCTorToW veHiCle SuSpenSion SYSTemBreaKaWaY SYSTem SaFeTY CHainSTrailer ligHTing and BraKing ConneCTor EmergenCY FlareS andTriangle reFleCTorSLock washer and hitch frame Trailer tongue. Wood or concrete blocks may also be usedCoupling the Trailer to the Tow vehicle Ball Coupler Attaching Safety Chain Breakaway Brake SystemBreakaway Cable Surge Brake System Pintle Coupler and pintle Hook Connecting Trailer lightsUncoupling the Ball Hitch PinTle HiTCH CouplerCoupling Trailer to Tow vehicle pintle Coupler Figure H. Attaching Safety Chain Pintle HitchTire SaFeTY Unsafe Tires, lug nuts or Wheels Determining load limit of TrailerBe sure lug nuts are tight before each tow Determining load limit of Tow vehicle Step StepLetter rating Speed rating Tire FundamenTalSUniform Tire Quality grading Standards uTQgS Tire Safety TipsTire repair Replacing Worn or damaged TiresWheel rims Wheels, Bearings and lug nutsLug nut Torque requirements Figure M. Trailer to Tow Vehicle Wiring Diagram Lights and SignalsHydraulic Hoses Schematic Maintenance Parts Locator Generator Wiring Diagram Generator Wiring Diagram Explanation of codes in remarks column Suggested spare parts SG1400C3 with Cummins QSB7-G5 Diesel Engine 1 to 3 unitsQty Description Housing Base assy EE33397 EE55742EE40474 BASE, 1400A STUDIO, 48 X EE6653Housing interior assy Door ASSY, Camlok SWITCH, OMRON, Enclosed LimitDoor ASSY, Left Side HANDLE, Door Assy PH110ZN LATCH, Door HANDLE, 2-POINTCAMLOK assy Bates CONN, 100A, 125V, Female PANEL, Output BUS, CamlokBUS BAR, 6 SET CAMLOK, 3 Spacing BUS BAR, Ground to NeutralControl box assy. panel Intelivision 5.7 Display SWITCH, TOGGLE, DPDT, ON/OFF/ONPANEL, INSTR, Intelivision HINGE, Control PNL MTGControl BOX assy. Interior BOX, Intelligen Control SWITCH, 15 MIN. Timer W/ ScrewsBOOT, DEUTCH, DRC26-24 BT BOOT, DEUTCH, DRC26-40 BTENGINE/GENERATOR Mounting assy FITTING, BULKHEAD, Brass 1/4 NPT Drive Disc Assy SAE #11.5Motor MOUNT, Fail SAFE, 840 LBS NUT PLATE, Base AssyRADIATOR/MUFFLER Support Unistrut CHANNEL, MFL Support SUPPORT, RadiatorCOVER, FAN, Steel ASSY, ARC Baffel W/ InsulationRADIATOR/FAN Assy BRACKET, Overflow Bottle WASHER, SAFETY, Hydraulic FANRADIATOR, Alum Overflow BOTTLE, RAD CoolantRadiator piping Mntg Head KIT, Coolant Filter Upper Water LineLower Water Line FILTER, COOLANT, SPIN-ONAIR Filter HOSING/PIPING CIA, TURBO, STYLE, 4 1/2 AIR FILTER, 13 DonaldsonBAND, Metal A/C Mntg Hump HOSE, STR. Rubber 5 IDExhaust assy BOLT, 4 Flat Mounting BAND, 16 RoundSILENCER, 16 Cylindrical TAILPIPE, 5 ExpandedSaddle BOX Assy CAPACITOR, 7.5 MFD DECAL, CAUTION, do not SwitchSWITCH, AUX, ABB REGULATOR, VOLTAGE, DVR2000EEngine starter, relay and batterY Assy RELAY, Starter Solenoid TRAY, BATTERY, 27-60, SSBOLT, BATTERY, 10.38 Long PANEL, Starter RelayFuel System Assy HOSE, BARB, Steel 3/8 FUEL-WATER SEPARATOR, RacorPUMP, FUEL, Stewart Warner PLATE, MTG, Fuel PumpFuel System Assy Street TEE, 1/2 Thread CLAMP, HOSE, 3/8ADAPTER, EXTENDED, 3/8 X 3/8 HYD. vent actuator hosing Assy FITTING, STRAIGHT, 3/8MJX3/8MAORB ANGLE, BracketEngine component Assy ACTUATOR, ETR Fuel Control FILTER, FuelAlternator PUMP, FuelHyd. MANIFOLD, Valve and Hose Assy BRACKET, HYD. Actuator Manifold MANIFOLD, HYD. ACTUATORS, 150 PSITest FITTING, Pressure Gauge CONN, DIN, PROPORTIONAL, SolenoidHyd. TANK, Filter and Hose Assy Tank ASSY., 7 GAL HYD Resivoir TEE, STREET, 1/2 NptfELEMENT, HYD. Filter Hyd. TANK, Filter and Hose Assy ELBOW, 90., Male Pipe Flame Resistant USMSHA2G-1C-14C/33 GoodyearTEE, UNION, 1/2 Nptr Hyd. PUMP, COOLER, FAN Motor and Hose Assy Test FITTING, Pressure Guage SAEJ20R3-HT-D3-EC, GoodyearCrankcase ventilation Assy HEAD, Crankcase Assy CANISTER, Crankcase AssyFILTER, High Density FILTER, Ultra DensityTrailer Assy NUT, HX. NYLOCK-INSERT, GRD PINTLE, EYE, RingCAP SCREW, HX. HD. GRD WASHER, Flat Zinc PLT /8FreigHT poliCY Terms and conditions of sale partsPage HERE’S HOW to GET Help

SG1400C3-55748 specifications

The Multiquip SG1400C3-55748 is an advanced generator designed for a wide array of applications, including construction sites, event management, and emergency power backup. At the heart of this robust unit lies a powerful engine that produces reliable energy output, ensuring that it meets the demands of both professionals and casual users alike.

The SG1400C3-55748 boasts an impressive power rating of 14 kW, making it suitable for powering multiple tools and equipment simultaneously. This generator is equipped with a durable and fuel-efficient engine, capable of running for extended periods without compromising performance. Efficient fuel consumption is a critical feature, allowing users to maximize productivity while minimizing operational costs.

One of the standout features of the SG1400C3-55748 is its advanced sound attenuation system. This generator is designed with a noise-reduced enclosure that significantly lowers operational sound levels, making it an excellent choice for noise-sensitive environments. This feature not only enhances user comfort but also complies with noise regulations that may be in effect at various job sites.

The Multiquip SG1400C3-55748 incorporates advanced technologies, including automatic voltage regulation (AVR), which offers stable power output and protects connected devices from voltage fluctuations. This is particularly beneficial for sensitive electronics and equipment that could be damaged by irregular power supply. The generator also features an easy-to-read control panel that allows users to monitor output levels and operating conditions effortlessly.

Safety is a priority for the SG1400C3-55748, featuring multiple safety mechanisms such as low oil shutdown and over-temperature protection. These features ensure that the generator operates within safe parameters, reducing the risk of damage to the unit and connected loads.

The portability of the Multiquip SG1400C3-55748 is enhanced by its compact design and integrated wheel kit, allowing easy transportation between job sites. Whether for emergency use, outdoor events, or construction, this generator offers the versatility and reliability needed for various applications.

In summary, the Multiquip SG1400C3-55748 is a powerful, efficient, and portable generator. Its advanced technologies, user-friendly features, and safety mechanisms make it an ideal choice for professionals and homeowners alike, ensuring that you have the reliable power you need when you need it most.