Multiquip SG1400C3-55748 manual General SaFeTY, GeneraTor SaFeTY

Page 7

Safety Information

general SaFeTY

CauTion

„never operate this equipment without proper protective clothing, shatterproof glasses, respiratory protection, hearing protection, steel-toed boots and other protective devices required by the job or city and state regulations.

„ never operate this equipment when not feeling well due to fatigue, illness or when under medication.

„never operate this equipment under the infl uence of drugs or alcohol.

„alWaYS check the equipment for loosened threads or bolts before starting.

„do noT use the equipment for any purpose other than its intended purposes or applications.

NOTICE

„This equipment should only be operated by trained and qualifi ed personnel 18 years of age and older.

„Whenever necessary, replace nameplate, operation and safety decals when they become diffi cult read.

„Manufacturer does not assume responsibility for any accident due to equipment modifi cations. Unauthorized equipment modifi cation will void all warranties.

„never use accessories or attachments that are not recommended by MQ Power for this equipment. Damage to the equipment and/or injury to user may result.

„ alWaYS know the location of the nearest fire extinguisher.

„ alWaYS know the location of the nearest first aid kit.

„alWaYS know the location of the nearest

phone or keep a phone on the job site. Also, know the phone numbers of the nearest ambulance, doctor and fire department. This information will be invaluable in the case of an emergency.

generaTor SaFeTY

danger

„never operate the equipment in an explosive atmosphere or near combustible materials.An explosion or fi re could result causing severe bodily harm or even death.

Warning

„never disconnect any emergency or safety devices. These devices are intended for operator safety. Disconnection of these devices can cause severe injury, bodily harm or even death. Disconnection of any of these devices will void all warranties.

CauTion

„never lubricate components or attempt service on a running machine.

NOTICE

„alWaYS ensure generator is on level ground before use.

„alWaYS keep the machine in proper running condition.

„Fix damage to machine and replace any broken parts immediately.

„alWaYS store equipment properly when it is not being used. Equipment should be stored in a clean, dry location out of the reach of children and unauthorized personnel

SG1400c3 studio generator • operation and parts manual — rev. #1 (02/15/12) — page 7

Image 7
Contents Model SG1400C3-55748 Proposition 65 warning Nhtsa Reporting Safety DefectsSpecifications are subject to change without notice Table of ContentsChoose from three easy options SaFeTY meSSageS Safety InformationSaFeTY SYmBolS GeneraTor SaFeTY General SaFeTYRestricted. If the air fl ow is Engine SaFeTYIf operating in speed ranges above the maximum allowable From fuel vapors or if fuel is spilled on a hot engine Fuel SaFeTYToWing SaFeTY „ never use fuel as a cleaning agentDeath EleCTriCal SaFeTYGrounding Safety Power Cord/Cable SafetyEnvironmenTal SaFeTY BaTTerY SaFeTYModel Cummins QSB7-G5 SpecificationsDimensions DimensionsTypical Generator Grounding Application InstallationIndoor Installation Outdoor InstallationGenerator Grounding General information Intake Ventilation Door Fuel TankFuel Priming Pump Fuel Water SeparatorInteliVision 5 Digital Controller Page Major Components Generator Major ComponentsDescription Starter Oil Filler CapAlternator Oil FilterLicense Plate Lights Illuminates license plate Basic Trailer ComponentsControl panel Controller Power Switch Provides power to engine controllerCamlok/Voltage Output Panel Camlok/voltage output panelMain Breaker Panel Circuit Breaker panelMCB Control Button Not functional in this application Digital controllerType of Load Single Phase LoadThree Phase Load Load application/generator outputGenerator Output Voltages Voltage Selector SwitchGenerator Amperage Fuel Check Inspection/setupRefueling Procedure Lubrication OilRemove fuel cap and fill tank Figure Only use #2 diesel fuel when refuelingWait for fuel to rise in filler neck Operation in Freezing Weather Cleaning the RadiatorAir Cleaner Fan Belt Tension Drive Belt inspection Coolant Antifreeze/summer coolantAlternator Battery Cable InstallationWiring When connecting the battery do the followingBefore Starting Always have adequate ventilation when operatingEngine’s exhaust contains harmful emissions Startup Engine will go to idle modeStarting Manual Emergency Shutdown Procedure Normal Shutdown ProcedureClosing the Enclosure DOORs Protective devices Protective devicesEngine Maintenance Schedule MaintenanceAir Filter Air Filter Dust IndicatorCleaning Inside the Fuel Tank General InspectionCheck Oil Level Fuel Tank InspectionReplacing Fuel Filter Air RemovalHydraulic Brake Actuator Manually Adjusting the BrakesTrailer Brakes Hydraulic BrakesWheel Bearings Adjustable ChannelLeaf Suspension Wheel Hub AdjustmentTroubleshooting Generator Troubleshooting generatorTroubleshooting Engine Troubleshooting engineTroubleshooting Intelivision 5 Controller Troubleshooting controllerCommon CauSeS For loSS oF Trailer Trailer guidelinesTrailer ToWing guidelineS Coupling To THe ToW veHiCle Driving CondiTionSTrailer ToWing TipS InoperaBle BraKeS, ligHTS or mirrorSTrailer vin Tag BraKe ConTroller EleCTriCal ConneCTorToW veHiCle SuSpenSion SYSTemBreaKaWaY SYSTem SaFeTY CHainSTrailer ligHTing and BraKing ConneCTor EmergenCY FlareS andTriangle reFleCTorSTrailer tongue. Wood or concrete blocks may also be used Lock washer and hitch frameCoupling the Trailer to the Tow vehicle Ball Coupler Breakaway Brake System Attaching Safety ChainBreakaway Cable Surge Brake System Pintle Coupler and pintle Hook Connecting Trailer lightsUncoupling the Ball Hitch PinTle HiTCH CouplerCoupling Trailer to Tow vehicle pintle Coupler Figure H. Attaching Safety Chain Pintle HitchDetermining load limit of Trailer Tire SaFeTY Unsafe Tires, lug nuts or WheelsBe sure lug nuts are tight before each tow Determining load limit of Tow vehicle Step StepLetter rating Speed rating Tire FundamenTalSUniform Tire Quality grading Standards uTQgS Tire Safety TipsTire repair Replacing Worn or damaged TiresWheels, Bearings and lug nuts Wheel rimsLug nut Torque requirements Figure M. Trailer to Tow Vehicle Wiring Diagram Lights and SignalsHydraulic Hoses Schematic Maintenance Parts Locator Generator Wiring Diagram Generator Wiring Diagram Explanation of codes in remarks column SG1400C3 with Cummins QSB7-G5 Diesel Engine 1 to 3 units Suggested spare partsQty Description Housing Base assy EE33397 EE55742EE40474 BASE, 1400A STUDIO, 48 X EE6653Housing interior assy Door ASSY, Camlok SWITCH, OMRON, Enclosed LimitDoor ASSY, Left Side HANDLE, Door Assy PH110ZN LATCH, Door HANDLE, 2-POINTCAMLOK assy Bates CONN, 100A, 125V, Female PANEL, Output BUS, CamlokBUS BAR, 6 SET CAMLOK, 3 Spacing BUS BAR, Ground to NeutralControl box assy. panel Intelivision 5.7 Display SWITCH, TOGGLE, DPDT, ON/OFF/ONPANEL, INSTR, Intelivision HINGE, Control PNL MTGControl BOX assy. Interior BOX, Intelligen Control SWITCH, 15 MIN. Timer W/ ScrewsBOOT, DEUTCH, DRC26-24 BT BOOT, DEUTCH, DRC26-40 BTENGINE/GENERATOR Mounting assy FITTING, BULKHEAD, Brass 1/4 NPT Drive Disc Assy SAE #11.5Motor MOUNT, Fail SAFE, 840 LBS NUT PLATE, Base AssyRADIATOR/MUFFLER Support Unistrut CHANNEL, MFL Support SUPPORT, RadiatorCOVER, FAN, Steel ASSY, ARC Baffel W/ InsulationRADIATOR/FAN Assy BRACKET, Overflow Bottle WASHER, SAFETY, Hydraulic FANRADIATOR, Alum Overflow BOTTLE, RAD CoolantRadiator piping Mntg Head KIT, Coolant Filter Upper Water LineLower Water Line FILTER, COOLANT, SPIN-ONAIR Filter HOSING/PIPING CIA, TURBO, STYLE, 4 1/2 AIR FILTER, 13 DonaldsonBAND, Metal A/C Mntg Hump HOSE, STR. Rubber 5 IDExhaust assy BOLT, 4 Flat Mounting BAND, 16 RoundSILENCER, 16 Cylindrical TAILPIPE, 5 ExpandedSaddle BOX Assy CAPACITOR, 7.5 MFD DECAL, CAUTION, do not SwitchSWITCH, AUX, ABB REGULATOR, VOLTAGE, DVR2000EEngine starter, relay and batterY Assy RELAY, Starter Solenoid TRAY, BATTERY, 27-60, SSBOLT, BATTERY, 10.38 Long PANEL, Starter RelayFuel System Assy HOSE, BARB, Steel 3/8 FUEL-WATER SEPARATOR, RacorPUMP, FUEL, Stewart Warner PLATE, MTG, Fuel PumpFuel System Assy CLAMP, HOSE, 3/8 Street TEE, 1/2 ThreadADAPTER, EXTENDED, 3/8 X 3/8 HYD. vent actuator hosing Assy FITTING, STRAIGHT, 3/8MJX3/8MAORB ANGLE, BracketEngine component Assy ACTUATOR, ETR Fuel Control FILTER, FuelAlternator PUMP, FuelHyd. MANIFOLD, Valve and Hose Assy BRACKET, HYD. Actuator Manifold MANIFOLD, HYD. ACTUATORS, 150 PSITest FITTING, Pressure Gauge CONN, DIN, PROPORTIONAL, SolenoidHyd. TANK, Filter and Hose Assy TEE, STREET, 1/2 Nptf Tank ASSY., 7 GAL HYD ResivoirELEMENT, HYD. Filter Hyd. TANK, Filter and Hose Assy Flame Resistant USMSHA2G-1C-14C/33 Goodyear ELBOW, 90., Male PipeTEE, UNION, 1/2 Nptr Hyd. PUMP, COOLER, FAN Motor and Hose Assy Test FITTING, Pressure Guage SAEJ20R3-HT-D3-EC, GoodyearCrankcase ventilation Assy HEAD, Crankcase Assy CANISTER, Crankcase AssyFILTER, High Density FILTER, Ultra DensityTrailer Assy NUT, HX. NYLOCK-INSERT, GRD PINTLE, EYE, RingCAP SCREW, HX. HD. GRD WASHER, Flat Zinc PLT /8FreigHT poliCY Terms and conditions of sale partsPage HERE’S HOW to GET Help

SG1400C3-55748 specifications

The Multiquip SG1400C3-55748 is an advanced generator designed for a wide array of applications, including construction sites, event management, and emergency power backup. At the heart of this robust unit lies a powerful engine that produces reliable energy output, ensuring that it meets the demands of both professionals and casual users alike.

The SG1400C3-55748 boasts an impressive power rating of 14 kW, making it suitable for powering multiple tools and equipment simultaneously. This generator is equipped with a durable and fuel-efficient engine, capable of running for extended periods without compromising performance. Efficient fuel consumption is a critical feature, allowing users to maximize productivity while minimizing operational costs.

One of the standout features of the SG1400C3-55748 is its advanced sound attenuation system. This generator is designed with a noise-reduced enclosure that significantly lowers operational sound levels, making it an excellent choice for noise-sensitive environments. This feature not only enhances user comfort but also complies with noise regulations that may be in effect at various job sites.

The Multiquip SG1400C3-55748 incorporates advanced technologies, including automatic voltage regulation (AVR), which offers stable power output and protects connected devices from voltage fluctuations. This is particularly beneficial for sensitive electronics and equipment that could be damaged by irregular power supply. The generator also features an easy-to-read control panel that allows users to monitor output levels and operating conditions effortlessly.

Safety is a priority for the SG1400C3-55748, featuring multiple safety mechanisms such as low oil shutdown and over-temperature protection. These features ensure that the generator operates within safe parameters, reducing the risk of damage to the unit and connected loads.

The portability of the Multiquip SG1400C3-55748 is enhanced by its compact design and integrated wheel kit, allowing easy transportation between job sites. Whether for emergency use, outdoor events, or construction, this generator offers the versatility and reliability needed for various applications.

In summary, the Multiquip SG1400C3-55748 is a powerful, efficient, and portable generator. Its advanced technologies, user-friendly features, and safety mechanisms make it an ideal choice for professionals and homeowners alike, ensuring that you have the reliable power you need when you need it most.