Recreational Vehicle Generator

ELECTRICAL HAZARDS

FIRE HAZARDS

The generator covered by this manual produces dangerous electrical voltages and can cause fatal electrical shock. Avoid contact with bare wires, ter- minals, connections, etc., while the unit is running. Ensure all appropriate covers, guards and barriers are in place before operating the generator. If work must be done around an operating unit, stand on an insulated, dry surface to reduce shock hazard.

Do not handle any kind of electrical device while standing in water, while barefoot, or while hands or feet are wet. DANGEROUS ELECTRICAL SHOCK MAY RESULT.

During installation onto the vehicle, properly ground (bond) the generator either by solid mount- ing to the vehicle frame or chassis, or by means of an approved bonding conductor. DO NOT connect the bonding conductor to any generator part that might be removed or disassembled during routine maintenance. If the grounding conductor must be replaced, use only a flexible conductor that is of No. 8 American Wire Gauge (AWG) copper wire minimum.

If the vehicle electrical circuits can be powered by any other source of electricity (such as a “dockside” power receptacle), there must be no possibility of connecting the different power sources to the vehi- cle circuits at the same time. The dockside (utility) power source must be positively isolated from the vehicle circuits whenever the generator is operat- ing. Failure to isolate the vehicle circuits from the dockside power supply when the generator is running may result in damage to the generator or serious injury or death to dockside (utility) power workers due to backfeed of electrical energy.

In case of accident caused by electric shock, imme- diately shut down the source of electrical power. If this is not possible, attempt to free the victim from the live conductor. AVOID DIRECT CONTACT WITH THE VICTIM. Use a nonconducting imple- ment, such as a rope or board, to free the victim from the live conductor. If the victim is uncon- scious, apply first aid and get immediate medical help.

Never wear jewelry when working on this equip- ment. Jewelry can conduct electricity resulting in electric shock, or may get caught in moving com- ponents causing injury.

For fire safety, the generator must be installed and maintained properly. Installation always must comply with applicable codes, standards, laws and regulations. Adhere strictly to local, state and national electrical and building codes. Comply with regulations the Occupational Safety and Health Administration (OSHA) has established. Also, ensure that the generator is installed in accordance with the manufacturer’s instructions and recommendations. Following proper installa- tion, do nothing that might alter a safe installation and render the unit in noncompliance with the aforementioned codes, standards, laws and regu- lations.

Keep a fire extinguisher in the vehicle at all times. Extinguishers rated “ABC” by the National Fire Protection Association are appropriate for use on the recreational vehicle generator electrical sys- tem. Keep the extinguisher properly charged and be familiar with its use. If there are any questions pertaining to fire extinguishers, consult the local fire department.

EXPLOSION HAZARDS

Do not smoke around the generator. Wipe up any fuel or oil spills immediately. Ensure that no com- bustible materials are left in the generator com- partment, or on or near the generator, as FIRE or EXPLOSION may result. Keep the area surround- ing the generator clean and free from debris.

Gasoline is extremely FLAMMABLE and its vapors are EXPLOSIVE. Do not permit smoking, open flame, sparks or any source of heat in the vicinity while handling gasoline. Comply with all laws gov- erning the storage and handling of gasoline.

Fuel lines must be properly installed and fastened, and free of leaks. There must be no possibility of gasoline vapors entering the vehicle interior.

It is required to install an approved, flexible, non- conductive fuel line between the generator fuel con- nection point and rigid fuel lines.

19

Image 21
Contents Air-cooled Recreational Vehicle Generators Introduction Authorized Service Dealer LocationPart Part II Installation Instructions Warning   Fire Hazards  Model Number Serial Number KW Rating Rated Voltage Generator IdentificationSpecifications SafetyGenerator Applicability ‹ 1.5.1 Fuel RequirementsFuel Consumption ‹ 1.5.5 GeneratorEngine OIL Requirements ‹ 1.5.6 Emissions Compliance PeriodGenerator Control Panel Automatic ChokeBefore Starting the Engine ‹ 2.4.2 Engine Lubrication Starting the Generator‹ 2.4.3 Fuel Supply ‹ 2.4.4 Cooling and Ventilating AIRStopping the Generator Applying Loads to GeneratorDo not Overload the Generator Protection Systems ‹ 2.9.3 Field Boost Additional Information‹ 2.10.2 Operation in High Grass or Brush ‹ 2.9.4 Overvoltage ProtectionChanging the Engine OIL AND/OR OIL Filter Checking the Engine OIL LevelMaintaining the Engine AIR Cleaner Clean AIR Intake‹ 3.3.1 Cleaning the Foam Precleaner Clean Spark Arrestor Cleaning the GeneratorFuel Filter OUT of Service Procedure Battery Maintenance‹ 3.12.1 Removal from Service Exercising the GeneratorAdjusting Valve Clearance RV Generator Service Interval‹ 3.12.2 Return to Service Recreational Vehicle Generator Part  General Hazards   Fire Hazards  Purpose and Scope Manual Equipment DescriptionStandards Booklets Major Features and Dimensions Drawing No D8716-H Location and Support ‹ 2.1.1 Generator Location‹ 2.1.2 Generator Support ‹ 2.1.4 Generator Restraint Generator Compartments‹ 2.2.2 Compartment Construction ‹ 2.2.1 Compartment Size‹ 2.2.3 Sound Insulating Materials ‹ 2.2.4 Acoustics‹ 2.3.1 Generator Airflow ‹ 2.2.5 Compartment Floor CutoutsCompartment Floor Cutout Drawing 0G3723-A Gasoline Fuel System ‹ 2.3.2 Testing the Installation‹ 2.4.1 Fuel Tank ‹ 2.4.2 Generator Fuel Supply LineExhaust System Flexible Fuel Line‹ 2.5.1 Spark Arrestor Electrical Connections ‹ 2.5.2 Exhaust System Safety‹ 2.6.5 Isolating Different Power Sources ‹ 2.6.6 Power Supply Cord‹ 2.6.4 Conduit Battery Installation ‹ 2.7.1 Recommended Battery‹ 2.7.2 Battery Cables Optional Accessories ‹ 2.7.4 Battery Compartment‹ 2.8.1 Remote START/STOP Panel Testing Under Load Post Installation TestsBefore Initial START-UP Initial StartInstallation Checklist Problem Cause Correction Troubleshooting GuideElectrical Data Customer Supplied by Recreational Vehicle Generator Enclosure Drawing No D8352-M QTY Description Recreational Vehicle Generator Generator Drawing No D8353-M FAN, 8 Curve BLADE, 16.5MM I.D Exploded Views and Parts Lists QTY Exploded Views and Parts Lists GUARD, FAN Exploded Views and Parts Lists Long Block Assembly Your Warranty Rights and Obligations MANUFACTURER’S Emission Control System Warranty CoveragePURCHASER’S/OWNER’S Warranty Responsibilities Emission Related Parts Include the Following Emission Control System WarrantyWarranty Schedule CONSUMER/PERSONAL Applications