Section 2 – Operation

Recreational Vehicle Generator

NOTE:

If starting from the generator control panel, turn OFF loads by setting the generator’s main circuit breaker to the OFF (or open) position. If starting from a remote panel, turn OFF loads using the means provided in the vehicle (such as a main circuit breaker). Electrical load circuits will be turned ON after the generator has started, stabi- lized and warmed up.

2.If the engine has not been started in more than two weeks, press the Fuel Pump Primer switch and hold it for about 10 to 15 seconds to prime the fuel system. However, if the engine is warm, skip Step 2.

3.Hold the engine Start/Stop switch in the START position to crank the engine. Release the switch when the engine starts.

If the engine does not start after it has been cranking for 15 seconds, release the Start/Stop switch, wait one minute and try again. Holding the switch for longer than 15 seconds can dam- age the starter motor.

4.Let the engine run at no-load for a few minutes to stabilize and warm up.

5.Turn ON electrical loads using the means provided (such as a main circuit breaker or transfer switch).

2.5stopping the generator

1.Turn OFF all electrical loads using the means provided (such as a main circuit breaker or transfer switch).

2.Let generator run at no-load for a few minutes, to stabilize internal engine generator temperatures.

If electrical loads are applied at reduced operating speeds, such loads imposed on the engine when suf- ficient power is not available may shorten engine life. Never turn ON electrical loads until after the genera- tor engine has started and stabilized at no-load.

2.7do not overload the

generator

Read the rated wattage/amperage capacity of the gen- erator on the generator data label (see Section 1.1).

Applying electrical loads in excess of the unit’s rated capacity will cause the engine/generator to automati- cally shut down.

To avoid overloading, add up the wattage of all con- nected electrical lighting, appliance, tool and motor loads. This total should not be greater than the generator’s rated wattage capacity.

Most lighting, appliance, tool and motor loads indicate their required watts on their nameplate or data plate. For light bulbs, simply note the wattage rating of the bulb.

If a load does not show its rated wattage, multiply that load’s rated VOLTS times AMPS to obtain

WATTS.

Induction type motors (such as those that run the vehicle’s furnace fan, refrigerator, air conditioner, etc.) need about 2-1/2 time more watts of power for starting than for running (for a few seconds during motor starting). Be sure to allow for this when con- necting electrical loads to the generator. First, fig- ure the watts needed to start electric motors in the system. To that figure, add the running wattages of other items that will be operated by the generator.

Do not apply heavy electrical loads for the first two or three hours of operation.

3. Place the Start/Stop switch in its STOP position.

2.6APPLYING LOADS TO GENERATOR

When applying electrical loads to the generator, observe these guidelines:

Before applying electrical loads, let the generator stabilize and warm up for a minute or two.

DO NOT overload the generator.

2.6.1 letting the engine stabilize

The generator supplies correct rated voltage only at the proper governed speed. Some electrical appli- ances may be extremely sensitive to voltage. Incorrect voltages can damage such appliances.

2.8Protection Systems

2.8.1 Low Oil Pressure Switch

This switch (Figure 2.2) has normally closed (N.C.) contacts that are held open by engine oil pressure dur- ing cranking and operating. Should oil pressure drop below a preset level, switch contacts close, and the engine automatically shuts down. The unit should not be restarted until oil is added.

2.8.2 High Temperature Switch

This switch (Figure 2.2), which has normally open (N.O.) contacts, is mounted near the oil filter. The contacts close if the temperature should exceed approximately 284º F (140º C), initiating an engine shutdown.



Image 10
Contents Air-cooled Recreational Vehicle Generators Introduction Authorized ServiceDealer Location Table of Contents  General Hazards   Electrical Hazards  Generator Identification ModelGenerator Applicability SafetySpecifications Generator ac Connection systemGenerator control panel Before starting the engine Optional remote Start/stop panelStarting the generator Do not overload Generator Stopping the generatorProtection Systems  2.8.4 overvoltage protection Additional Information 2.8.3 field boost  2.9.1 25-HOUR BREAK-IN PeriodLevel Checking the Engine OILCHANGing the Engine OIL And/or Oil Filter  3.3.1 cleaning the Foam Precleaner Maintaining The Engine AIR CleanerClean air intake  3.3.2 cleaning or replacing the paper filterCleaning the Generator Clean spark arrestorChecking the Engine Spark Plug Out of Service Procedure Battery MaintenanceExercising the Generator Rv generator service interval Adjusting Valve Clearance 3.11.2 Return To Service Part Installation Instructions  General Hazards   Electrical Hazards   Fire Hazards  Generator Engine Operating Speed Purpose and ScopeEquipment Description Generator AC Connection SystemView from TOP Location and Support  2.1.1 Generator Location 2.2.1 Compartment Size Generator Compartments 2.2.2 Compartment Construction  2.2.3 Sound Insulating Materials  2.2.4 Acoustics 2.2.5 Compartment Floor Cutouts Cooling and Ventilating Air 2.3.1 Generator airflow  2.4.1 Parts not Included in Fuel System  2.3.2 Testing the InstallationLP Gas Fuel System  2.4.2 Some Important Considerations 2.4.5 Gaseous Carburetion  2.4.3 vapor withdrawal 2.4.4 primary regulator  2.4.6 fuel supply lines 2.4.8 leakage tests Exhaust System 2.5.1 Spark Arrestor Electrical Connections  2.5.2 Exhaust System Safety 2.6.2 Wiring  2.6.1 Electrical Junction BOX 2.6.3 Generator AC Connections  2.6.6 Power Supply Cord 2.6.4 Conduit 14 Transfer Switch Isolation Method  2.7.4 Battery Compartment Optional Accessories 2.7.3 Battery Cable Connections  2.8.1 remote start/stop panelBefore Initial START-UP Post Installation TestsTesting Under Load Initial StartInstallation Checklist Troubleshooting Guide Problem Cause CorrectionAppendix 2 Electrical Data Supplied by Customer 24 7 QTY Description 21 2 ASSEMBLY, Brush Holder 274 Regulator Voltage Appendix 3 Exploded Views and Parts Lists GUARD, FAN Appendix 3 Exploded Views and Parts Lists Long Block Assembly 220 RV LP Recreational Vehicle Generator Regulator Drawing No F5819 CASTING, Twin Regulator Housing MANUFACTURER’S Emission Control System Warranty Coverage Your Warranty Rights and ObligationsPURCHASER’S/OWNER’S Warranty Responsibilities Emission Control System Warranty Emission Related Parts Include the FollowingWarranty Schedule Consumer/Personal Applications

004701-0 specifications

Guardian Technologies 004701-0 is a state-of-the-art air purifier designed to enhance indoor air quality and create a healthier living environment. This innovative device utilizes advanced technologies to combat airborne pollutants, allergens, and other harmful particles, making it an excellent choice for homes, offices, and other indoor spaces.

One of the standout features of the Guardian Technologies 004701-0 is its powerful True HEPA filtration system. True HEPA filters are capable of capturing 99.97% of particles as small as 0.3 microns, including dust, pollen, smoke, and pet dander. This ensures that the air you breathe is free from common allergens and irritants, promoting overall health and well-being.

In addition to its HEPA filter, the device incorporates a UV-C light technology that works to eliminate harmful bacteria and viruses. This dual-action air purification method not only filters out physical particles but also reduces the presence of microorganisms, further enhancing the air quality in your space. The UV-C light operates effectively without any chemicals, making it a safe and eco-friendly choice.

The Guardian Technologies 004701-0 is designed with user convenience in mind. It features a sleek, compact design that fits seamlessly into any room decor, and it operates quietly, ensuring that it does not disrupt your daily activities or sleep. The device also comes with multiple speed settings, allowing users to adjust the airflow based on their preferences and the size of the room.

Another notable characteristic of this air purifier is its filter replacement indicator. This feature alerts users when it’s time to replace the filter, ensuring that the unit operates at peak performance without any guesswork. The ease of maintenance makes it simple for users to keep the purifier running efficiently.

In conclusion, the Guardian Technologies 004701-0 is a powerful air purifier that combines advanced filtration and sanitization technologies to create a cleaner and healthier indoor environment. With its True HEPA filter, UV-C light, user-friendly design, and convenient features, it stands out as a reliable solution for improving indoor air quality and overall health. Whether you are looking to reduce allergens or simply breathe cleaner air, the Guardian Technologies 004701-0 is a wise investment for any household or workspace.