Guardian Technologies 004701-0 owner manual Battery Maintenance, Exercising the Generator

Page 15

Section 3 – Maintenance

Recreational Vehicle Generator

Do NOT use a forceful spray of water to clean the generator. Water will enter the generator interior and cause problems, and may also con- taminate the generator fuel system.

3.8Battery Maintenance

All lead-acid batteries will discharge when not in use. The generator battery should be inspected as follows:

3.8.1 Weekly

Inspect the battery posts and cables for tightness and corrosion. Tighten and clean as necessary.

Check the battery fluid level of unsealed batteries and, if necessary, fill with Distilled Water Only. Do not use tap water in batteries.

3.8.2 Every Six Months

Have the state of charge and condition checked. This should be done with an automotive-type bat- tery hydrometer.

Note:

Servicing of the battery is to be performed or supervised by personnel knowledgeable of batter- ies and the required precautions. Keep unauthor- ized personnel away from batteries.

Damage will result if the battery connections are made in reverse.

danger

Do not dispose of the battery in a fire. The battery is capable of exploding. Storage bat- teries give off explosive hydrogen gas. This gas can form an explosive mixture around the bat- tery for several hours after charging. The slight- est spark can ignite the gas and cause an explo- sion. Such an explosion can shatter the battery and cause blindness or other injury. Any area that houses a storage battery must be properly ventilated. Do not allow smoking, open flame, sparks, or any spark producing tools or equip- ment near the battery. Discharge static electric- ity from body before touching the battery by first touching a grounded metal surface.

A battery presents a risk of electrical shock and high short circuit current. The following precautions are to be observed when working on batteries:

Remove watches, rings or other metal objects;

Use tools with insulated handles;

Wear rubber gloves and boots;

Do not lay tools or metal parts on top of the battery;

Disconnect any charging source prior to connecting or disconnecting battery terminals; and

Do not use any jumper cables or booster battery to crank and start the generator engine. If any battery has discharged, remove it for recharging.

Do not open or mutilate the battery. Released electrolyte has been known to be harmful to the skin and eyes, and to be toxic.

The electrolyte is a dilute sulfuric acid that is harmful to the skin and eyes. It is electrically conductive and corrosive. The following procedures are to be observed:

Wear full eye protection and protective clothing;

Where electrolyte contacts the skin, wash it off immediately with water;

Where electrolyte contacts the eyes, flush thoroughly and immediately with water and seek medical attention; and

Spilled electrolyte is to be washed down with an acid neutralizing agent. A common practice is to use a solution of 1 pound (500 grams) bicarbonate of soda to 1 gallon (4 liters) or water. The bicar- bonate of soda solution is to be added until the evidence of reaction (foaming) has ceased. The resulting liquid is to be flushed with water and the area dried.

3.9Major Service Manual

To obtain a service manual for the generator, contact the nearest Authorized Service Dealer or. Make sure to identify the MODEL NUMBER and SERIES.

3.10 Exercising the Generator

The manufacturer recommends that the generator be started and operated at least once every seven days. Let the unit run for at least 30 minutes to “exercise” the engine.

3.11 Out of Service Procedure

3.11.1 Removal From Service

If the generator cannot be exercised every seven days, and it is to be out of service longer than 30 days, pre- pare the generator for storage as follows:

1.Start the engine and let it warm up.

2.Close the fuel shutoff valve in the fuel supply line and allow the unit to shut down.

NOTE:

Using a fuel additive such as STA-BIL fuel stabi- lizer, or an equivalent, will prevent gum deposits from forming in the engine’s fuel system.

13

Image 15
Contents Air-cooled Recreational Vehicle Generators Authorized Service IntroductionDealer Location Table of Contents  General Hazards   Electrical Hazards  Model Generator IdentificationGenerator ac Connection system SafetySpecifications Generator ApplicabilityGenerator control panel Optional remote Start/stop panel Before starting the engineStarting the generator Stopping the generator Do not overload GeneratorProtection Systems  2.9.1 25-HOUR BREAK-IN Period Additional Information 2.8.3 field boost  2.8.4 overvoltage protectionChecking the Engine OIL LevelCHANGing the Engine OIL And/or Oil Filter  3.3.2 cleaning or replacing the paper filter Maintaining The Engine AIR CleanerClean air intake  3.3.1 cleaning the Foam PrecleanerClean spark arrestor Cleaning the GeneratorChecking the Engine Spark Plug Battery Maintenance Out of Service ProcedureExercising the Generator Adjusting Valve Clearance Rv generator service interval 3.11.2 Return To Service Part Installation Instructions  General Hazards   Electrical Hazards   Fire Hazards  Generator AC Connection System Purpose and ScopeEquipment Description Generator Engine Operating SpeedView from TOP  2.1.1 Generator Location Location and SupportGenerator Compartments  2.2.1 Compartment Size 2.2.2 Compartment Construction  2.2.4 Acoustics  2.2.3 Sound Insulating MaterialsCooling and Ventilating Air  2.2.5 Compartment Floor Cutouts 2.3.1 Generator airflow  2.4.2 Some Important Considerations  2.3.2 Testing the InstallationLP Gas Fuel System  2.4.1 Parts not Included in Fuel System 2.4.6 fuel supply lines  2.4.3 vapor withdrawal 2.4.4 primary regulator  2.4.5 Gaseous CarburetionExhaust System  2.4.8 leakage tests 2.5.1 Spark Arrestor  2.6.1 Electrical Junction BOX  2.5.2 Exhaust System Safety 2.6.2 Wiring Electrical Connections 2.6.6 Power Supply Cord  2.6.3 Generator AC Connections 2.6.4 Conduit 14 Transfer Switch Isolation Method  2.8.1 remote start/stop panel Optional Accessories 2.7.3 Battery Cable Connections  2.7.4 Battery CompartmentInitial Start Post Installation TestsTesting Under Load Before Initial START-UPInstallation Checklist Problem Cause Correction Troubleshooting GuideAppendix 2 Electrical Data Supplied by Customer 24 7 QTY Description 21 2 ASSEMBLY, Brush Holder 274 Regulator Voltage Appendix 3 Exploded Views and Parts Lists GUARD, FAN Appendix 3 Exploded Views and Parts Lists Long Block Assembly 220 RV LP Recreational Vehicle Generator Regulator Drawing No F5819 CASTING, Twin Regulator Housing Your Warranty Rights and Obligations MANUFACTURER’S Emission Control System Warranty CoveragePURCHASER’S/OWNER’S Warranty Responsibilities Emission Related Parts Include the Following Emission Control System WarrantyWarranty Schedule Consumer/Personal Applications

004701-0 specifications

Guardian Technologies 004701-0 is a state-of-the-art air purifier designed to enhance indoor air quality and create a healthier living environment. This innovative device utilizes advanced technologies to combat airborne pollutants, allergens, and other harmful particles, making it an excellent choice for homes, offices, and other indoor spaces.

One of the standout features of the Guardian Technologies 004701-0 is its powerful True HEPA filtration system. True HEPA filters are capable of capturing 99.97% of particles as small as 0.3 microns, including dust, pollen, smoke, and pet dander. This ensures that the air you breathe is free from common allergens and irritants, promoting overall health and well-being.

In addition to its HEPA filter, the device incorporates a UV-C light technology that works to eliminate harmful bacteria and viruses. This dual-action air purification method not only filters out physical particles but also reduces the presence of microorganisms, further enhancing the air quality in your space. The UV-C light operates effectively without any chemicals, making it a safe and eco-friendly choice.

The Guardian Technologies 004701-0 is designed with user convenience in mind. It features a sleek, compact design that fits seamlessly into any room decor, and it operates quietly, ensuring that it does not disrupt your daily activities or sleep. The device also comes with multiple speed settings, allowing users to adjust the airflow based on their preferences and the size of the room.

Another notable characteristic of this air purifier is its filter replacement indicator. This feature alerts users when it’s time to replace the filter, ensuring that the unit operates at peak performance without any guesswork. The ease of maintenance makes it simple for users to keep the purifier running efficiently.

In conclusion, the Guardian Technologies 004701-0 is a powerful air purifier that combines advanced filtration and sanitization technologies to create a cleaner and healthier indoor environment. With its True HEPA filter, UV-C light, user-friendly design, and convenient features, it stands out as a reliable solution for improving indoor air quality and overall health. Whether you are looking to reduce allergens or simply breathe cleaner air, the Guardian Technologies 004701-0 is a wise investment for any household or workspace.