Guardian Technologies 004701-0 owner manual  General Hazards 

Page 18

Safety Rules

Recreational Vehicle Generator

DANGER: For fire safety, installation of a generator into a recreational vehicle must comply strictly with article 551, NFPA 70; ANSI C1-1975; AND, ANSI A119.2-1975/NFPA 501C “Standard for Recreational Vehicles” (Part 3, “Installation of Electrical Systems”). In addition, installation must comply with the manufacturer’s instructions and recommendations.

Notice to Installer

These Installation Instructions have been published by the manufacturer to aid in the installation of the products described in this manual. The manufac- turer assumes that installation personnel are familiar with the procedures for installing such products, or similar products. The manufacturer also assumes that personnel have been trained in the recommend- ed installation procedures for these products and that such training includes (a) use of common hand tools, (b) use of special tools, and (c) use of any tools and/or equipment from other suppliers.

The manufacturer cannot anticipate every possible circumstance that might involve a hazard. The warn- ings in this manual, and on tags and decals affixed to the unit, are, therefore, not all inclusive. If using a procedure, work method or operating technique the manufacturer does not specifically recommend, ensure that it is safe for others. Also make sure the procedure, work method or operating technique uti- lized does not render the generator unsafe.

Information, illustrations, specifications, etc., con- tained in these Installation Instructions are based on the latest information available at the time of publica- tion. Every effort has been expended to be sure that such data is both accurate and current. However, the manufacturer reserves the right to change, alter or otherwise improve this product at any time without prior notice.

danger

Despite the safe design of this generator, operating this equipment imprudently, neglecting its maintenance or being careless can cause possible injury or death. Permit only responsible and capable persons to operate or maintain this equipment.

Potentially lethal voltages are generated by these machines. Ensure all steps are taken to render the machine safe before attempting to work on the generator.

Parts of the generator are rotating and/or hot during operation. Exercise care near running generators.

General Hazards

For safety reasons, the manufacturer recommends that the installation, initial start-up and main- tenance of this equipment is carried out by an Authorized Service Dealer.

The engine exhaust fumes contain carbon monox- ide, which can be DEADLY. This dangerous gas, if breathed in sufficient concentrations, can cause unconsciousness or even death. This exhaust system must be installed properly, in strict com- pliance with applicable codes and standards. Following installation, do nothing that might ren- der the system unsafe or in noncompliance with such codes and standards. The generator com- partment must be completely vapor sealed from the vehicle interior. There must be no possibility of exhaust fumes entering the vehicle interior. Never operate this equipment with a leaking or defective exhaust system.

Keep hands, feet, clothing, etc., away from drive belts, fans, and other moving or hot parts. Never remove any drive belt or fan guard while the unit is operating.

Adequate, unobstructed flow of cooling and ven- tilating air is critical to correct generator opera- tion and is required to expel toxic fumes and fuel vapors from the generator compartment. Without sufficient cooling airflow, the engine/generator quickly overheats, which causes serious damage to the generator. Do not alter the installation or permit even partial blockage of ventilation provi- sions, as this can seriously affect safe operation of the generator.

When working on this equipment, remain alert at all times. Never work on the equipment when physically or mentally fatigued.

Before performing any maintenance on the gen- erator, disconnect its battery cables to prevent accidental start up. Disconnect the cable from the battery post indicated by a NEGATIVE, NEG or (–) first. Reconnect that cable last.

Never use the generator or any of its parts as a step. Stepping on the unit can stress and break parts, and may result in dangerous operating con- ditions from leaking exhaust gases, fuel leakage, oil leakage, etc.

Never insert any tool or other object through open- ings in the generator interior, even if the unit is not running. Serious injury or damage to the equip- ment may occur.

16

Image 18
Contents Air-cooled Recreational Vehicle Generators Authorized Service IntroductionDealer Location Table of Contents  General Hazards   Electrical Hazards  Generator Identification ModelGenerator Applicability SafetySpecifications Generator ac Connection systemGenerator control panel Optional remote Start/stop panel Before starting the engineStarting the generator Stopping the generator Do not overload GeneratorProtection Systems  2.8.4 overvoltage protection Additional Information 2.8.3 field boost  2.9.1 25-HOUR BREAK-IN PeriodChecking the Engine OIL LevelCHANGing the Engine OIL And/or Oil Filter  3.3.1 cleaning the Foam Precleaner Maintaining The Engine AIR CleanerClean air intake  3.3.2 cleaning or replacing the paper filterClean spark arrestor Cleaning the GeneratorChecking the Engine Spark Plug Battery Maintenance Out of Service ProcedureExercising the Generator Adjusting Valve Clearance Rv generator service interval 3.11.2 Return To Service Part Installation Instructions  General Hazards   Electrical Hazards   Fire Hazards  Generator Engine Operating Speed Purpose and ScopeEquipment Description Generator AC Connection SystemView from TOP Location and Support  2.1.1 Generator LocationGenerator Compartments  2.2.1 Compartment Size 2.2.2 Compartment Construction  2.2.3 Sound Insulating Materials  2.2.4 AcousticsCooling and Ventilating Air  2.2.5 Compartment Floor Cutouts 2.3.1 Generator airflow  2.4.1 Parts not Included in Fuel System  2.3.2 Testing the InstallationLP Gas Fuel System  2.4.2 Some Important Considerations 2.4.5 Gaseous Carburetion  2.4.3 vapor withdrawal 2.4.4 primary regulator  2.4.6 fuel supply linesExhaust System  2.4.8 leakage tests 2.5.1 Spark Arrestor Electrical Connections  2.5.2 Exhaust System Safety 2.6.2 Wiring  2.6.1 Electrical Junction BOX 2.6.6 Power Supply Cord  2.6.3 Generator AC Connections 2.6.4 Conduit 14 Transfer Switch Isolation Method  2.7.4 Battery Compartment Optional Accessories 2.7.3 Battery Cable Connections  2.8.1 remote start/stop panelBefore Initial START-UP Post Installation TestsTesting Under Load Initial StartInstallation Checklist Troubleshooting Guide Problem Cause CorrectionAppendix 2 Electrical Data Supplied by Customer 24 7 QTY Description 21 2 ASSEMBLY, Brush Holder 274 Regulator Voltage Appendix 3 Exploded Views and Parts Lists GUARD, FAN Appendix 3 Exploded Views and Parts Lists Long Block Assembly 220 RV LP Recreational Vehicle Generator Regulator Drawing No F5819 CASTING, Twin Regulator Housing Your Warranty Rights and Obligations MANUFACTURER’S Emission Control System Warranty CoveragePURCHASER’S/OWNER’S Warranty Responsibilities Emission Control System Warranty Emission Related Parts Include the FollowingWarranty Schedule Consumer/Personal Applications

004701-0 specifications

Guardian Technologies 004701-0 is a state-of-the-art air purifier designed to enhance indoor air quality and create a healthier living environment. This innovative device utilizes advanced technologies to combat airborne pollutants, allergens, and other harmful particles, making it an excellent choice for homes, offices, and other indoor spaces.

One of the standout features of the Guardian Technologies 004701-0 is its powerful True HEPA filtration system. True HEPA filters are capable of capturing 99.97% of particles as small as 0.3 microns, including dust, pollen, smoke, and pet dander. This ensures that the air you breathe is free from common allergens and irritants, promoting overall health and well-being.

In addition to its HEPA filter, the device incorporates a UV-C light technology that works to eliminate harmful bacteria and viruses. This dual-action air purification method not only filters out physical particles but also reduces the presence of microorganisms, further enhancing the air quality in your space. The UV-C light operates effectively without any chemicals, making it a safe and eco-friendly choice.

The Guardian Technologies 004701-0 is designed with user convenience in mind. It features a sleek, compact design that fits seamlessly into any room decor, and it operates quietly, ensuring that it does not disrupt your daily activities or sleep. The device also comes with multiple speed settings, allowing users to adjust the airflow based on their preferences and the size of the room.

Another notable characteristic of this air purifier is its filter replacement indicator. This feature alerts users when it’s time to replace the filter, ensuring that the unit operates at peak performance without any guesswork. The ease of maintenance makes it simple for users to keep the purifier running efficiently.

In conclusion, the Guardian Technologies 004701-0 is a powerful air purifier that combines advanced filtration and sanitization technologies to create a cleaner and healthier indoor environment. With its True HEPA filter, UV-C light, user-friendly design, and convenient features, it stands out as a reliable solution for improving indoor air quality and overall health. Whether you are looking to reduce allergens or simply breathe cleaner air, the Guardian Technologies 004701-0 is a wise investment for any household or workspace.