Guardian Technologies 004701-0 owner manual  Electrical Hazards   Fire Hazards 

Page 19

Safety Rules

Recreational Vehicle Generator

Electrical Hazards

Fire Hazards

The generator covered by this manual produces dangerous electrical voltages and can cause fatal electrical shock. Avoid contact with bare wires, ter- minals, connections, etc., while the unit is running. Ensure all appropriate covers, guards and barriers are in place before operating the generator. If work must be done around an operating unit, stand on an insulated, dry surface to reduce shock hazard.

Do not handle any kind of electrical device while standing in water, while barefoot, or while hands or feet are wet. DANGEROUS ELECTRICAL SHOCK MAY RESULT.

During installation onto the vehicle, properly ground (bond) the generator either by solid mount- ing to the vehicle frame or chassis, or by means of an approved bonding conductor. DO NOT connect the bonding conductor to any generator part that might be removed or disassembled during routine maintenance. If the grounding conductor must be replaced, use only a flexible conductor that is of No. 8 American Wire Gauge (AWG) copper wire minimum.

If the vehicle electrical circuits can be powered by any other source of electricity (such as a “dockside” power receptacle), there must be no possibility of connecting the different power sources to the vehi- cle circuits at the same time. The dockside (utility) power source must be positively isolated from the vehicle circuits whenever the generator is operat- ing. Failure to isolate the vehicle circuits from the dockside power supply when the generator is running may result in damage to the generator or serious injury or death to dockside (utility) power workers due to backfeed of electrical energy.

In case of accident caused by electric shock, imme- diately shut down the source of electrical power. If this is not possible, attempt to free the victim from the live conductor. AVOID DIRECT CONTACT WITH THE VICTIM. Use a nonconducting imple- ment, such as a rope or board, to free the victim from the live conductor. If the victim is uncon- scious, apply first aid and get immediate medical help.

Never wear jewelry when working on this equip- ment. Jewelry can conduct electricity resulting in electric shock, or may get caught in moving com- ponents causing injury.

For fire safety, the generator must be installed and maintained properly. Installation always must comply with applicable codes, standards, laws and regulations. Adhere strictly to local, state and national electrical and building codes. Comply with regulations the Occupational Safety and Health Administration (OSHA) has established. Also, ensure that the generator is installed in accordance with the manufacturer’s instructions and recommendations. Following proper installa- tion, do nothing that might alter a safe installation and render the unit in noncompliance with the aforementioned codes, standards, laws and regula- tions.

Keep a fire extinguisher in the vehicle at all times. Extinguishers rated “ABC” by the National Fire Protection Association are appropriate for use on the recreational vehicle generator electrical system. Keep the extinguisher properly charged and be familiar with its use. If there are any question per- taining to fire extinguishers, consult the local fire department.

Explosion Hazards

Do not smoke around the generator. Wipe up any fuel or oil spills immediately. Ensure that no com- bustible materials are left in the generator com- partment, or on or near the generator, as FIRE or EXPLOSION may result. Keep the area surround- ing the generator clean and free from debris.

Gasoline is extremely FLAMMABLE and its vapors are EXPLOSIVE. Do not permit smoking, open flame, sparks or any source of heat in the vicinity while handling gasoline. Comply with all laws gov- erning the storage and handling of gasoline.

Fuel lines must be properly installed and fastened, and free of leaks. There must be no possibility of gasoline vapors entering the vehicle interior.

You are required to install an approved, flexible, nonconductive fuel line between the generator fuel connection point and rigid fuel lines.

17

Image 19
Contents Air-cooled Recreational Vehicle Generators Introduction Authorized ServiceDealer Location Table of Contents  General Hazards   Electrical Hazards  Model Generator IdentificationGenerator ac Connection system SafetySpecifications Generator ApplicabilityGenerator control panel Before starting the engine Optional remote Start/stop panelStarting the generator Do not overload Generator Stopping the generatorProtection Systems  2.9.1 25-HOUR BREAK-IN Period Additional Information 2.8.3 field boost  2.8.4 overvoltage protectionLevel Checking the Engine OILCHANGing the Engine OIL And/or Oil Filter  3.3.2 cleaning or replacing the paper filter Maintaining The Engine AIR CleanerClean air intake  3.3.1 cleaning the Foam PrecleanerCleaning the Generator Clean spark arrestorChecking the Engine Spark Plug Out of Service Procedure Battery MaintenanceExercising the Generator Rv generator service interval Adjusting Valve Clearance 3.11.2 Return To Service Part Installation Instructions  General Hazards   Electrical Hazards   Fire Hazards  Generator AC Connection System Purpose and ScopeEquipment Description Generator Engine Operating SpeedView from TOP  2.1.1 Generator Location Location and Support 2.2.1 Compartment Size Generator Compartments 2.2.2 Compartment Construction  2.2.4 Acoustics  2.2.3 Sound Insulating Materials 2.2.5 Compartment Floor Cutouts Cooling and Ventilating Air 2.3.1 Generator airflow  2.4.2 Some Important Considerations  2.3.2 Testing the InstallationLP Gas Fuel System  2.4.1 Parts not Included in Fuel System 2.4.6 fuel supply lines  2.4.3 vapor withdrawal 2.4.4 primary regulator  2.4.5 Gaseous Carburetion 2.4.8 leakage tests Exhaust System 2.5.1 Spark Arrestor  2.6.1 Electrical Junction BOX  2.5.2 Exhaust System Safety 2.6.2 Wiring Electrical Connections 2.6.3 Generator AC Connections  2.6.6 Power Supply Cord 2.6.4 Conduit 14 Transfer Switch Isolation Method  2.8.1 remote start/stop panel Optional Accessories 2.7.3 Battery Cable Connections  2.7.4 Battery CompartmentInitial Start Post Installation TestsTesting Under Load Before Initial START-UPInstallation Checklist Problem Cause Correction Troubleshooting GuideAppendix 2 Electrical Data Supplied by Customer 24 7 QTY Description 21 2 ASSEMBLY, Brush Holder 274 Regulator Voltage Appendix 3 Exploded Views and Parts Lists GUARD, FAN Appendix 3 Exploded Views and Parts Lists Long Block Assembly 220 RV LP Recreational Vehicle Generator Regulator Drawing No F5819 CASTING, Twin Regulator Housing MANUFACTURER’S Emission Control System Warranty Coverage Your Warranty Rights and ObligationsPURCHASER’S/OWNER’S Warranty Responsibilities Emission Related Parts Include the Following Emission Control System WarrantyWarranty Schedule Consumer/Personal Applications

004701-0 specifications

Guardian Technologies 004701-0 is a state-of-the-art air purifier designed to enhance indoor air quality and create a healthier living environment. This innovative device utilizes advanced technologies to combat airborne pollutants, allergens, and other harmful particles, making it an excellent choice for homes, offices, and other indoor spaces.

One of the standout features of the Guardian Technologies 004701-0 is its powerful True HEPA filtration system. True HEPA filters are capable of capturing 99.97% of particles as small as 0.3 microns, including dust, pollen, smoke, and pet dander. This ensures that the air you breathe is free from common allergens and irritants, promoting overall health and well-being.

In addition to its HEPA filter, the device incorporates a UV-C light technology that works to eliminate harmful bacteria and viruses. This dual-action air purification method not only filters out physical particles but also reduces the presence of microorganisms, further enhancing the air quality in your space. The UV-C light operates effectively without any chemicals, making it a safe and eco-friendly choice.

The Guardian Technologies 004701-0 is designed with user convenience in mind. It features a sleek, compact design that fits seamlessly into any room decor, and it operates quietly, ensuring that it does not disrupt your daily activities or sleep. The device also comes with multiple speed settings, allowing users to adjust the airflow based on their preferences and the size of the room.

Another notable characteristic of this air purifier is its filter replacement indicator. This feature alerts users when it’s time to replace the filter, ensuring that the unit operates at peak performance without any guesswork. The ease of maintenance makes it simple for users to keep the purifier running efficiently.

In conclusion, the Guardian Technologies 004701-0 is a powerful air purifier that combines advanced filtration and sanitization technologies to create a cleaner and healthier indoor environment. With its True HEPA filter, UV-C light, user-friendly design, and convenient features, it stands out as a reliable solution for improving indoor air quality and overall health. Whether you are looking to reduce allergens or simply breathe cleaner air, the Guardian Technologies 004701-0 is a wise investment for any household or workspace.