Guardian Technologies 004701-0 owner manual Maintaining The Engine AIR Cleaner, Clean air intake

Page 13

Section 3 – Maintenance

Change the engine oil filter after the first 25 hours of operation, and every 100 operating hours there- after.

To change the oil and/or oil filter, proceed as follows (see Figure 3.1):

1.Run the engine until it is thoroughly warmed up (at least five minutes) then shut OFF the engine.

2.Immediately after the engine shuts OFF, pull the oil drain cover free of the base. Remove the plug from the tube with a 5/16” allen wrench and drain the oil into a suitable container. Loosening the oil fill cap will allow the crankcase to drain faster.

3.After the oil has drained, replace the plug onto the end of the oil drain tube. Retain the cover in the base.

4.With the oil drained, remove the old oil filter by turning it counterclockwise. Place a towel under- neath to catch excess oil.

5.Apply a light coating of clean engine oil to the gas- ket of the new filter. Fill the filter until saturated with clean oil.

6.Screw the new filter on by hand until its gasket lightly contacts the oil filter adapter. Then, tighten the filter an additional 3/4 to one turn.

7.Remove the dipstick and wipe it dry with a clean, lint-free cloth. This will be used later to check the oil level.

8.Remove the oil fill cap on the oil fill tube and slowly add the proper type and amount of recom- mended oil (see Section 1.5.4). Periodically use the dipstick to check the oil level and continue to fill the crankcase until the oil reaches the dipstick “Full” mark. DO NOT FILL ABOVE THE “FULL” MARK.

9.Install and tighten the oil fill cap and the dipstick before operating the engine.

10.Start the engine and check for leaks.

NOTE:

Check the oil level and fill to the “FULL” mark after checking for leaks. The filter will retain some oil.

3.3Maintaining The ENGINE AIR CLEANER

3.3.1 cleaning the Foam Precleaner

Clean and re-oil the foam precleaner every three months or every 25 hours of operation, whichever occurs first. Service the foam precleaner more fre- quently if operating the generator in extremely dusty or dirty conditions. Use the following procedure (Figure 3.2):

1.Turn the two screws counterclockwise to loosen.

2.Remove the cover, foam precleaner and paper filter.

Recreational Vehicle Generator

3.Remove the foam precleaner from the cover.

4.Wash the foam precleaner in liquid detergent and water.

5.Wrap the foam precleaner in a clean cloth and gently squeeze it dry.

6.Saturate the foam precleaner in clean engine oil. Gently squeeze it in a clean cloth to remove excess oil and to distribute oil (DO NOT TWIST).

7.Install the foam precleaner into the cover, fol- lowed by the paper filter.

8.Install the cover, foam precleaner and paper filter.

9.Tighten the two screws to retain the filter in place.

Figure 3.2 – Engine Air Cleaner

3.3.2 cleaning or replacing the paper filter

Once each year or every 100 hours of operation (whichever comes first), clean or replace the paper filter. The new replacement filter must be flame retardant. Service the paper filter more frequently if operating the generator in extremely dusty or dirty conditions. Use the following procedure (Figure 3.2):

1.Follow steps 1-3 in Section 3.3.1; service the foam precleaner if necessary.

2.Remove the paper filter.

3.Clean the air filter by tapping it gently on a solid surface. If the filter is too dirty, replace it with a new one. Dispose of the old filter properly.

4.Clean the air cleaner cover then reassemble following steps 7-9 in Section 3.3.1.

3.4Clean air intake

Clean all foreign material from the air intake (Figure 3.3) at least once every 100 hours of operation. Clean more often if necessary.

Inspect the area around the generator exhaust muf- fler periodically and remove all grass, leaves, dirt, etc., from this area.

11

Image 13
Contents Air-cooled Recreational Vehicle Generators Introduction Authorized ServiceDealer Location Table of Contents  General Hazards   Electrical Hazards  Model Generator IdentificationSpecifications SafetyGenerator Applicability Generator ac Connection systemGenerator control panel Before starting the engine Optional remote Start/stop panelStarting the generator Do not overload Generator Stopping the generatorProtection Systems  2.8.3 field boost Additional Information 2.8.4 overvoltage protection  2.9.1 25-HOUR BREAK-IN PeriodLevel Checking the Engine OILCHANGing the Engine OIL And/or Oil Filter Clean air intake Maintaining The Engine AIR Cleaner 3.3.1 cleaning the Foam Precleaner  3.3.2 cleaning or replacing the paper filterCleaning the Generator Clean spark arrestorChecking the Engine Spark Plug Out of Service Procedure Battery MaintenanceExercising the Generator Rv generator service interval Adjusting Valve Clearance 3.11.2 Return To Service Part Installation Instructions  General Hazards   Electrical Hazards   Fire Hazards  Equipment Description Purpose and ScopeGenerator Engine Operating Speed Generator AC Connection SystemView from TOP  2.1.1 Generator Location Location and Support 2.2.1 Compartment Size Generator Compartments 2.2.2 Compartment Construction  2.2.4 Acoustics  2.2.3 Sound Insulating Materials 2.2.5 Compartment Floor Cutouts Cooling and Ventilating Air 2.3.1 Generator airflow LP Gas Fuel System  2.3.2 Testing the Installation 2.4.1 Parts not Included in Fuel System  2.4.2 Some Important Considerations 2.4.4 primary regulator  2.4.3 vapor withdrawal 2.4.5 Gaseous Carburetion  2.4.6 fuel supply lines 2.4.8 leakage tests Exhaust System 2.5.1 Spark Arrestor  2.6.2 Wiring  2.5.2 Exhaust System SafetyElectrical Connections  2.6.1 Electrical Junction BOX 2.6.3 Generator AC Connections  2.6.6 Power Supply Cord 2.6.4 Conduit 14 Transfer Switch Isolation Method  2.7.3 Battery Cable Connections Optional Accessories 2.7.4 Battery Compartment  2.8.1 remote start/stop panelTesting Under Load Post Installation TestsBefore Initial START-UP Initial StartInstallation Checklist Problem Cause Correction Troubleshooting GuideAppendix 2 Electrical Data Supplied by Customer 24 7 QTY Description 21 2 ASSEMBLY, Brush Holder 274 Regulator Voltage Appendix 3 Exploded Views and Parts Lists GUARD, FAN Appendix 3 Exploded Views and Parts Lists Long Block Assembly 220 RV LP Recreational Vehicle Generator Regulator Drawing No F5819 CASTING, Twin Regulator Housing MANUFACTURER’S Emission Control System Warranty Coverage Your Warranty Rights and ObligationsPURCHASER’S/OWNER’S Warranty Responsibilities Emission Related Parts Include the Following Emission Control System WarrantyWarranty Schedule Consumer/Personal Applications

004701-0 specifications

Guardian Technologies 004701-0 is a state-of-the-art air purifier designed to enhance indoor air quality and create a healthier living environment. This innovative device utilizes advanced technologies to combat airborne pollutants, allergens, and other harmful particles, making it an excellent choice for homes, offices, and other indoor spaces.

One of the standout features of the Guardian Technologies 004701-0 is its powerful True HEPA filtration system. True HEPA filters are capable of capturing 99.97% of particles as small as 0.3 microns, including dust, pollen, smoke, and pet dander. This ensures that the air you breathe is free from common allergens and irritants, promoting overall health and well-being.

In addition to its HEPA filter, the device incorporates a UV-C light technology that works to eliminate harmful bacteria and viruses. This dual-action air purification method not only filters out physical particles but also reduces the presence of microorganisms, further enhancing the air quality in your space. The UV-C light operates effectively without any chemicals, making it a safe and eco-friendly choice.

The Guardian Technologies 004701-0 is designed with user convenience in mind. It features a sleek, compact design that fits seamlessly into any room decor, and it operates quietly, ensuring that it does not disrupt your daily activities or sleep. The device also comes with multiple speed settings, allowing users to adjust the airflow based on their preferences and the size of the room.

Another notable characteristic of this air purifier is its filter replacement indicator. This feature alerts users when it’s time to replace the filter, ensuring that the unit operates at peak performance without any guesswork. The ease of maintenance makes it simple for users to keep the purifier running efficiently.

In conclusion, the Guardian Technologies 004701-0 is a powerful air purifier that combines advanced filtration and sanitization technologies to create a cleaner and healthier indoor environment. With its True HEPA filter, UV-C light, user-friendly design, and convenient features, it stands out as a reliable solution for improving indoor air quality and overall health. Whether you are looking to reduce allergens or simply breathe cleaner air, the Guardian Technologies 004701-0 is a wise investment for any household or workspace.