MAINTENANCE
MAINTENANCE
FLAILHEAD
1.Frequently inspect the rotor assembly for damaged or missing flails. Bolts and nuts securing the flails to the rotor should be regularly checked and kept tight. The correct torque setting for these locknuts is 135 Nm (100 lbs/ft.). Use only the correct flail bolt and locking nut. Check the flail pivot bushes for possible damage or wear. They do not require oil.
2.Do not attempt to run the rotor with flails missing. Imbalance will cause severe vibration and can rapidly damage the rotor shaft bearings. As an emergency measure, if a flail is broken off or lost, remove another on the opposite site of the rotor to retain balance. Always replace flails in opposite pairs and never match up a new flail with a resharpened one which will of course be lighter.
3.Blunt flails absorb a lot of power and leave an untidy finish to work. They should be sharpened on a grindstone or with a portable grinder periodically.
4.Wear protective gear when sharpening flails.
5.Ensure that the bearing housings and hydraulic mounting nuts and bolts are kept tight. They should be checked during servicing.
CABLES
The cables operate on a push/pull system with the spool centering springs always returning the spool to the neutral position when the handle is released.
Care should be taken during installation and operation to ensure that the cables are not trapped or kinked. Any abrasion or damage to the outer casing should be sealed with plastic insulation tape to avoid moisture penetrating.
No routine adjustment of the cables are necessary as they do not stretch. The threaded collar is correctly adjusted when the lever is in a vertical position in its housing allowing an equal amount of travel in either direction.
Do not lubricate the cables which are assembled with a special lubricant during manufacture.
NOTE: Be careful in determining the correct cable connections on both the control unit and the valve in the event of cable replacement.
RMB 1445 11/10 | Maintenance Section |
© 2010 Alamo Group Inc.