Exmark TTS20KAE523, TTS16KA483 Pre-Start, Operating Instructions, Open the Fuel Shut-Off Valve

Page 19

Operation

Pre-Start

Fill fuel tank on level ground. For best results use only clean, fresh regular grade unleaded gasoline with an octane rating of 87 or higher.

Important: Never use methanol, gasoline containing methanol, gasohol containing more than 10% ethanol, premium gasoline, or white gas because the fuel system could be damaged.

Do Not add oil to gasoline.

Do Not overfill fuel tank. Fill the fuel tank to the bottom of the filler neck. The empty space in the tank allows gasoline to expand. Overfilling may result in fuel leakage or damage to the engine or emission system (if equipped).

Make sure you understand the controls, their locations, their functions, and their safety requirements.

Refer to the Maintenance section and perform all the necessary inspection and maintenance steps.

Note: After starting the engine and engaging the hydro drive, if either of the drive wheels acts sluggish or will not rotate at all, stop engine and refer to the Hydraulic System Air Purge Procedure in Maintenance.

Operating Instructions

Open the Fuel Shut-Off Valve

Rotate the valve 1/4 turn counterclockwise to turn fuel on.

Starting the Engine (Manual Start)

Note: Operator must have PTO disengaged and speed control lever in neutral position when starting the engine.

1.Lock drive levers in neutral and engage park brake.

Note: A cold weather starting kit has been added for ease of starting in either cold weather or when the unit has not been run for a period of time.

To use cold start kit:

A.Pull split ring straight out the side of the unit, and hook the ring over the lower rear hydro control shield bolt.

B.Start engine. Refer to the following guidelines for further starting suggestions.

To engage pump drive (disengage cold start kit):

A.Pull chain straight out from the side of the unit until the split ring can be removed from the bolt.

B.Slowly release tension on chain.

2.Pull out the choke control. Place the throttle control midway between the “Slow” and “Fast” positions.

3.Turn the key switch to the “Run” position.

4.Pull recoil rope to start engine.

5.After engine warms up, gradually push in the choke control. Do Not run warm engine with the choke in the “ON” position.

Note: Kawasaki engines generally need to be “choked” even when warm.

Starting the Engine (Electric Start)

Note: Operator must have PTO disengaged, speed control lever in neutral position, and OPC levers depressed when starting the engine.

1.Lock drive levers in neutral and engage park brake.

2.Pull out the choke control. Place the throttle control midway between the “Slow” and “Fast” positions.

3.Turn the ignition switch to the “Start” position. Release the switch as soon as the engine starts.

Important: Do Not crank the engine continuously for more than ten seconds at a time. If the engine does not start, allow a 60 second starter cool-down period between starting attempts. Failure to follow these guidelines can burn out the starter motor.

4.After engine warms up, gradually push in the choke control. Do Not run warm engine with the choke in the “ON” position.

Note: Kawasaki engines generally need to be “choked” even when warm.

19

Image 19
Contents Turf Tracer Series California Introduction Contents Training SafetySafety Alert Symbol Safe Operating PracticesSafety Slope Operation OperationMaintenance and Storage Safety Safety and Instructional Decals 413327 103-1977 109-3148 116-0404 117-2718 Model Numbers SpecificationsSystems Dimensions Torque Requirements Product OverviewControls OperationPark Brake Lever Off-Run Switch Manual Start OnlyIgnition Switch Electric Start Only Tracking Adjustment KnobStarting the Engine Manual Start Pre-StartOperating Instructions Open the Fuel Shut-Off ValveDrive Lever/Neutral Lock Latch Operation Disengaging the PTOStopping the Engine Driving the MachineDriving Forward Adjusting the Cutting HeightDriving in Reverse Adjusting the Anti-Scalp Rollers Transporting a Unit TransportingRecommended Maintenance Schedules MaintenanceCheck Engine Oil Level Check Battery Charge Electric Start Units OnlyProposition 65 Warning Do Not jump start a weak battery if these conditions exist Service Interval As requiredCheck Mower Blades Install bushing/blade assembly into spindleReplacing the Discharge Deflector Service Air Cleaner Check Safety Interlock SystemCheck for Loose Hardware Check Hydraulic Oil Level Change Engine OilCheck Tire Pressures Check Condition Of BeltsLevel Check Spark PlugsChange Fuel Filter Change Hydraulic System FilterHydraulic System Air Purge Torque the slotted nut to 140-155 ft-lb 190-210 N-m Wheel Hub-Slotted Nut Torque SpecificationReplace Emissions Air Intake Filter Style a black finishCopper-Based Anti-seize Inspect PTO Clutching Belt TensionThread Locking Adhesives Mobil HTS Grease Or Food-Grade Anti-seizePump Drive Belt Tension Park Brake AdjustmentHydro Drive Linkage Adjustment Deck LevelingRepeat above adjustments if necessary Adjust Hydro Control LinkagesHydro Pump Spring Tension Setting Tracking AdjustmentDrive Lever Linkage Adjustment Retighten PTO switch mounting hardware PTO Safety SwitchClean Engine and Exhaust System Area Remove Engine Shrouds and Clean Cooling FinsWaste Disposal Clean Debris From MachineClean Grass Build-Up Under Deck Battery DisposalProblem Possible Cause Corrective Action TroubleshootingTroubleshooting Electrical Diagram SchematicsSchematics Hydraulic Diagram Exmark Commercial Turf Equipment Date Description of Work Done Service Done By Service RecordPage This page may be copied for personal use See EXMARK’S Complete Line of Accessories and Options