Husqvarna Rider 318 Checking the blades, Replacing the blades, Removing the BioClip plug, Combi

Page 25

Maintenance

Checking the blades

WARNING! Wear gloves to protect your

!hands when working with the blades.

To achieve the best mowing results it is important that the blades are undamaged and well-sharpened.

Check that the blades’ attachment screws are tight.

IMPORTANT INFORMATION

One or more unbalanced blades , caused by damage or poor balancing after sharpening, can cause vibrations in the machine.

The blades should be balanced after sharpening.

Damaged blades should be replaced when hitting obstacles that result in a breakdown.

Replacing the blades

1Put the unit in the service position, see Service position for the cutting unit.

2Lock the blade with a wooden block. Loosen the blade bolt and remove the blade bolt, the washer and the blade.

Assemble the parts in the reverse order.

1The blade must be mounted with the angled ends pointing up towards the cover.

2Tightening torque 45-50 Nm (4.5-5 kpm/32-36 lbft).

15mm

WARNING! Wear gloves to protect your

!hands when working with the blades.

IMPORTANT INFORMATION Always exercise care and use your common sense. Avoid all situations which you consider to be beyond your capability. If you still feel uncertain about operating procedures after reading these instructions, you should consult an expert before continuing. Contact an authorised service workshop.

Always use genuine parts. For more information, see the ”Technical data” section.

Removing the BioClip plug

To change a Combi unit from BioClip function to cutting unit with rear ejection, remove the BioClip plug located under the unit with three screws.

Combi 103, Combi 112

1Put the unit in the service position, see Placing in the service position.

2Remove the three screws holding the BioClip plug, and remove the plug.

3Tip: Fit three full-thread screws M8x15 mm in the screw holes to protect the threads.

4Replace the unit in normal position.

Fit the BioClip plug in the reverse order.

Combi 94

1Put the unit in the service position, see Placing in the service position.

2Loosen the knob and the bolts holding the BioClip plug and remove the plug.

English – 25

Image 25
Contents Rider 318 Rider 320 AWD Contents Pre-delivery service Service journalAfter the first 8 hours Introduction Symbols KEY to SymbolsKEY to Symbols Location of the controls What is WHAT?Safety instructions Safety InstructionsInsure your Rider General useThis is what you do Driving on slopesChildren MaintenanceTransport Presentation Fueling SeatRelease lever Release lever RiderBefore starting DrivingStart the engine Starting a cold engineConnecting the jump leads Starting the engine with a weak batteryDriving the Rider Stop the engineMaintenance schedule MaintenanceChecking and adjusting the steering wires CleaningRemoving of the machine hoods Adjusting the parking brake Rider 320 AWD Adjusting the parking brake RiderChecking and adjusting of throttle wire Can result in reduced braking abilityReplacing the air filter Replacement of fuel filterChecking the fuel pump’s air filter Cool before starting to replace the air filterIgnition system Check the safety systemMain fuse Checking the tyre pressureTrapping your hand Fitting the cutting headRemoving the cutting unit Adjusting the parallelism of the cutting unitChecking the cutting unit’s parallelism Replacing the cutting unit belts Placing in the service position Service position for the cutting unitRestoring from service position Replacing the blades Checking the bladesRemoving the BioClip plug Combi 103, CombiChecking the engine’s oil level LubricationChanging the oil filter Replacing the engine oilChecking the transmission oil level Lubricating the belt adjusterGeneral lubrication Troubleshooting schedule Storage ServiceWinter storage GuardTechnical Data Cutting unit Combi EC Declaration of Conformity Applies to Europe onlyBlade Original instructions 1156985-26 ´z+X§T¶6X¨ ´z+X§T¶6X¨