Cino FM400 manuals
Computer Equipment > Scanner
When we buy new device such as Cino FM400 we often through away most of the documentation but the warranty.
Very often issues with Cino FM400 begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Scanner Cino FM400 is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Scanner on our side using links below.
67 pages 779.6 Kb
2 Revision History 4 Table of Contents Getting Started Configure Your FuzzyScan Appendix 5 Getting Familiar with Your FuzzyScan FM400 Series (Front-view Model) FM400 Series (Side-view Model) 6 Connect to Your Host USB Models (FM4xx-11x) RS232 Models (FM4xx-00x) Universal Models (FM4xx-98x) 7 Install Your FuzzyScan Adjust Reading Angle Mount Your FuzzyScan 8 Use the Test Mode 9 Use Your FuzzScan External Trigger and Serial Trigger Scan Input Time-out OK/NG Signals Operation Modes 11 Bar Code Programming Menu 14 Single scan selection Single scan selectionSingle scan selectionSingle scan selection Multiple scans selection Multiple scans selectionMultiple scans selection Multiple scans selection Scan PROGRAM Scan One of Family Codes Scan One of Option Codes Repeat Selection Scan END Yes 15 Cycling scan selection Cycling scan selectionCycling scan selectionCycling scan selection Dual level selection Dual level selectionDual level selection Dual level selection Scan PROGRAM Scan One of Family Codes Scan One of Option Codes Repeat Selection Scan END Scan FIN Scan One of Family Codes (1st) Scan Several Option Codes Scan PROGRAM Repeat Selection Scan END (2nd) Scan One or Several Option Codes 16 Host Interface Selection PROGRAM 17 User Defined Symbol ID F_DEFAULT Parameter Selection Option Code 2nd Option Code Symbol ID : 1 character 18 Symbology ID Transmission 19 Readable Bar Code Setting F_DEFAULT Parameter Selection Option Code Readable Symbology Setting PROGRAM 22 Codabar/NW-7 Setting F_DEFAULT Parameter Selection Option Code Codabar Setting Codabar Min. Length Codabar Max. Length PROGRAM 23 UPC-A & UPC-E Setting F_DEFAULT Parameter Selection Option Code UPC Family Setting PROGRAM 24 UPC-A & UPC-E Setting , Supplement Scan Voting F_DEFAULT Parameter Selection Option Code UPC Supplement Setting UPC/EAN Security Level Supplement Scan Voting PROGRAM 25 EAN Setting , Supplement , Supplement Scan Voting F_DEFAULT Parameter Selection Option Code EAN Setting EAN Supplement Setting Supplement Scan Voting PROGRAM 26 UPC/EAN Security Level Setting , EAN Supplement Control F_DEFAULT Parameter Selection Option Code UPC/EAN Security Level EAN Supplement Control PROGRAM 28 IATA & Interleaved 2 of 5 Setting F_DEFAULT Parameter Selection Option Code IATA Setting Interleaved 2 of 5 Setting 29 Code 25 Family Setting 30 Code 11 & Code 93 Setting 31 MSI/Plessey Setting 32 Code 128 & UCC/EAN 128 Setting 33 UK/Plessey Setting 34 Telepen Setting 35 GS1 DataBar Setting F_DEFAULT Parameter Selection Option Code GS1 DataBar Setting GS1 DataBar Min. Length GS1 DataBar Max. Length 36 Linear-stacked & Korea Post Code Setting 37 Keyboard Layout (Language) Setting F_DEFAULT Parameter Selection Option Code Keyboard Layout 38 Record Suffix, Preamble, Postamble & Caps Lock 39 Delay Setting 40 Emulation Setting & Upper/Lower Case Setting 41 Record Suffix, Preamble, Postamble Setting F_DEFAULT Parameter Selection Option Code STX/ETX Control Record Suffix Preamble Postamble 42 Delay Setting 43 Protocol, ACK/NAK Setting 44 Time Out Setting, Baud Rate, Data Frame F_DEFAULT Parameter Selection Option Code Serial Response Time-out Baud Rate (BPS) Data Frame PROGRAM 45 Operation Mode Setting F_DEFAULT Parameter Selection Option Code Operation Mode 46 Buzzer, Indicator, Inverse Reading 47 Dollar Sign, Redundancy, Scan Rate Control F_DEFAULT Parameter Selection Option Code Dollar Sign Control Redundancy Scan Rate Control PROGRAM 48 Delay Setting F_DEFAULT Parameter Selection Option Code Reread Delay (Double San Verification) Good Read Delay PROGRAM 49 Time-out and Duration Setting F_DEFAULT Parameter Selection Option Code Scan Input Time-out Hands Free Time-out Good Read Duration 50 Presentation Scanning Setting 51 OK/NG Signal and Beeping Control F_DEFAULT Parameter Selection Option Code OK/NG Signal Active State OK/NG Signal Output Control NG Message Output OK/NG Signal Duration OK/NG Beeping Control PROGRAM 53 Preamble, Postamble, Data Length & Symbol ID Trans. F_DEFAULT Parameter Selection Option Code Preamble Postamble Data Length Transmission Symbology ID Transmission PROGRAM 54 Data Formatter Setting F_DEFAULT 2nd Option Code Formatter Control 1st Insertion 2nd Insertion 3rd Insertion 4th Insertion PROGRAM 55 Data Verifier Setting F_DEFAULT 2nd Option Code Verifier Control Identified Data Length 1st Identified Character 2nd Identified Character 3rd Identified Character 56 Data Replacer Setting 57 Data Organizer Setting 58 Select a Bar Code Symbology Select a Bar Code SymbologySelect a Bar Code Symbology Select a Bar Code Symbology Position Calculation Position CalculationPosition Calculation Position Calculation [Data Formatter] [Data Verifier, Data Replacer, Data Organizer] Application Example Application ExampleApplication Example Application Example 59 Programming Procedure Programming ProcedureProgramming ProcedureProgramming Procedure [Data Verifier] [Data Formatter] [Data Replacer] [Data Organizer] [Important Notice] 60 Symbology ID Table 61 Keyboard Function Code Table 62 ASCII Input Shortcut HEX/ASCII Reference Table 63 Host Interface Quick Set Operation Mode Quick Set 64 Option Codes 65 System Commands 66 Indications Normal Operation Test Mode Reading Rate Information
Also you can find more Cino manuals or manuals for other Computer Equipment.