Symbology Reading Control

Readable Bar Code Setting

PROGRAM

Family Code Selection

P.C

Parameter Selection

 

 

 

F_DEFAULT

Option Code

FixedMount Manual

Readable Symbology Setting

Remember to scan “FIN” to terminate

this selection. But if you select the

Auto ”, FuzzyScan will terminate this selection automatically.

SS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS

Auto ￿

Code 128 *

UPC-A *

UPC-E *

EAN-13 *

EAN-8 *

Codabar/NW-7 *

Code 39 *

Trioptic Code 39

Standard/Industrial 2 of 5

Matrix 2 of 5

Interleaved 2 of 5 *

China Postal Code

German Postal Code

Code 93 *

Code 11

MSI/Plessey

UK/Plessey

Telepen

GS1 DataBar (RSS-14) *

IATA

PDF417/Micro PDF417

Codablock F

Korea Post Code

00

01

02

03

04

05

06

07

47

08

38

48

58

68

09

10

11

12

13

14

15

17

18

21

FuzzyScan

Scan

Programming

￿If your application is known, you may select those known symbologies only to increase the reading speed and decrease the possibility of reading error. Furthermore, to add the “Symbology ID” into the transmitted data is also helpful to identify the specific symbology.

￿Above symbologies marketed with * are enable as default. When you select “Auto”, the imager only read those symbologies marked with *.

￿When you set the minimum and maximum length of each symbology, please note the data length of scanned bar code doesn’t include star/stop characters.