Symbology Reading Control

UPC-A & UPC-E Setting

PROGRAM

Family Code Selection

P.C

Parameter Selection

 

 

 

F_DEFAULT

Option Code

UPC Family Setting

SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS

Disable UPC-A

Enable UPC-A ￿

Disable UPC-E

Enable UPC-E ￿

Disable UPC-E expansion ￿ Enable UPC-E expansion Disable UPC standardization ￿ Enable UPC standardization Disable UPC numeric system Enable UPC numeric system ￿ Disable UPC-A check digit transmission Enable UPC-A check digit transmission ￿ Disable UPC-E check digit transmission Enable UPC-E check digit transmission ￿ Disable UPC “leading 1” portion ￿ Enable UPC “leading 1” portion

0

1

2

3

4

5

6

7

8

9 A B C D E F

￿When enable UPC-E expansion, the UPC-E decoded data will be converted to UPC-A format and affected by related setting, such as UPC standardization, UPC numeric system, UPC-A check digit transmission.

￿ UPC-E & EAN-8 Expansion

: Expand the 8-digit UPC-E and 8-digit ENA-8 to 12-digit UPC-A and 13-digit EAN-13.

￿ UPC-A Standardization

: Expand the 12-digit UPC-A to 13-digit EAN-13 with 1 zero insertion.

￿ UPC Lead 1 Numeric System

: Enable to read UPC leading with the 1 numeric system, you must enable this option.

Mount

Manual

FuzzyScan Fixed

Scan

Programming

WPC Selection (UPC/EAN/CAN)

UPC-A

UPC-E

EAN-13

EAN-8

Basic Length

12

8

13

8

Disable

Check Digit

-1

-1

-1

-1

Disable

With 2-digit

With 5-digit

Enable

Numeric System

Addendum

Addendum

Standardization

 

 

 

 

- 1

+ 2

+ 5

+ 1

- 1

+ 2

+ 5

+ 1

NC

+ 2

+ 5

NC

NC

+ 2

+ 5

NC

 

 

 

 

Enable

Expansion

0

+4

0

+5

19

Page 23