Mount

Manual

FuzzyScanFixed

Programming

 

Scan

 

 

Symbology Reading Control

Code 39 Setting

PROGRAM

 

 

 

 

 

F_DEFAULT

 

 

 

 

 

 

 

Family Code Selection

 

P.C

 

Parameter Selection

 

Option Code

 

 

 

 

 

 

 

Code 39 Security Level

 

SS

 

Level 0

 

0

 

 

 

 

 

 

 

 

SS

 

Level 1

 

1

 

 

SS

 

Level 2 ￿

 

2

 

 

SS

 

Level 3

 

3

 

 

 

 

 

 

 

￿Code 39 Security Level

The scanner offers four levels of decode security for Code39 bar codes:

Level 0: If you are experiencing misread of poorly-printed or serious out-of-spec. bar codes in level 1, please select level 0.

Level 1: If you are experiencing misread of poorly-printed or out-of-spec. bar codes in level 2, please select level 1.

Level 2: This is the default setting which allows the scanner to operate fastest, while providing sufficient security in decoding “in-spec” Code39 bar codes.

Level 3: If you failed to read poorly-printed or out-of-spec. bar codes in level 2, please select level 3. This is the most aggressive setting and may increase the misread.

17

Page 21
Image 21
Cino FM400 manual Code 39 Setting