The readability may be impacted by the specular reflection caused by the perpendicular reading angle. To get the most optimal reading performance, you are suggested to install the FM400 at an approximate 15° angle to the perpendicular line of the target barcode. However, the reading angle and distance may vary depending on the size and printing quality of barcodes.

Front-view

Side-view

Mount Your FuzzyScan

There are two M3 mounting holes on the bottom of the chassis. Please follow below procedures to mount your scanner.

Prepare two appropriate M3 screws (minimal 4mm in depth) and decide your desired mounting location. Then adjust the two screws to accommodate 27mm center width.

Optimize the mounting position by adjusting the reading angle and distance. Ensure the illumination envelop is not blocked by any external object.

Use the test mode to verify the actual reading rate. If the reading rate is not good enough, please adjust the reading angle and distance to get the optimum readability.