FuzzyScan Fixed Mount
Scan
Programming Manual
40

PROGRAM

Serial Interface Control
Time Out Setting, Baud Rate, Data Frame

F_DEFAULT

Family Code Selection P.C

Parameter Selection Option Code

Serial Response Time-out

SS
SS
SS
MS
None
200 mseconds
500 mseconds
1 second
2 seconds
5 seconds
User defined value (seconds)
0
1
2
3
4
5
6, (2 digits)

Baud Rate (BPS)

SS
SS
SS
SS
38.4K BPS
19.2K BPS
9600 BPS
4800 BPS
2400 BPS
1200 BPS
57.6K BPS
115.2K BPS
0
1
2
3
4
5
8
9

Data Frame

SS
SS
SS
SS
SS
SS
SS
SS
8, None, 1
8, Odd, 1
8, Even, 1
8, Space, 1
8, Mark, 1
8, None, 2
7, Odd, 1
7, Even, 1
7, Space, 1
7, Mark, 1
7, None, 2
7, Odd, 2
7, Even, 2
7, Space, 2
7, Mark, 2
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
When the RTS/CTS Hardwa re Handshaking option is selected, the RTS (request to send) and CTS (clear to send) signals will be issued before normal dat a
communication. This option is very helpful to ensure the reliability of data communication.
The Serial Response Time-out is a pre-defined delay time for FuzzyScan to wait for handshaking, acknowledgment or non-acknowledgment from the host computer.