Mount

Manual

FuzzyScanFixed

Programming

 

Scan

 

 

Condensed DataWizard

Preamble, Postamble, Data Length & Symbol ID Trans.

PROGRAM

 

 

 

 

 

 

 

F_DEFAULT

 

 

 

 

 

 

 

 

 

Family Code Selection

 

P.C

 

 

Parameter Selection

 

Option Code

 

 

 

 

 

 

 

 

 

Preamble

 

SS

 

 

None ￿

 

FIN

 

 

 

 

 

 

 

 

 

 

MS

 

 

1-15 characters

 

[00-7F], [FIN]

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum 15-character input; scan “FIN” to terminate this selection.

 

 

 

 

 

 

 

 

 

 

 

Postamble

 

SS

 

 

None ￿

 

FIN

 

 

 

 

 

 

 

 

 

 

MS

 

 

1-15 characters

 

[00-7F], [FIN]

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum 15-character input; scan “FIN” to terminate this selection.

 

 

 

 

 

 

 

 

 

 

 

Data Length Transmission

 

SS

 

 

Disable ￿

 

0

 

 

 

 

 

 

 

 

 

 

SS

 

 

Enable 2 digits data length transmission

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

If data length exceeds 99, 3-digit data length will be transmitted.

 

 

 

 

 

 

 

 

 

 

 

Symbology ID Transmission

 

SS

 

 

Disable symbology ID transmission ￿

 

0

 

 

 

 

 

 

 

 

 

 

SS

 

 

Enable prefix symbology ID transmission

 

1

 

 

SS

 

 

Enable suffix symbology ID transmission

 

2

 

 

SS

 

 

Enable both prefix and suffix symbology ID transmission

 

3

 

 

SS

 

 

Enable prefix AIM symbology ID transmission

 

4

 

 

SS

 

 

Enable suffix AIM symbology ID transmission

 

5

 

 

SS

 

 

Enable both prefix and suffix AIM symbology ID transmission

 

6

￿DataWizard is the most powerful, Artificial-Intelligence based data editing expert system provided specially for the FuzzyScan family bar code readers. Through DataWizard, you can process the scanned data prior the transmissions in many ways as: Insert, Delete, Match, Verify, Replace, Reorganize, and Repeat Transmission. It will help you to arrange the transmission of scanned data to any specific format without software modification.

￿Due to the resources used by this system, Full-feature DataWizard is only supported by PowerTool. Through the PowerTool, all settings and configurations can be done on-screen, under Windows 95/98/NT/2000/XP environment.

￿A Condensed Version DataWizard is provided by each FuzzyScan series. Through this menu, the condensed DataWizard can be utilized via bar code menu readings with ease.

￿Please note that all “Character” input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value.

￿If you have any problem to use DataWizard, please refer to following pages for details and consult your local FuzzyScan vendor or our web site for any assistance.