Lenox P506640-01 manuals
Household Appliance > Air Conditioner
When we buy new device such as Lenox P506640-01 we often through away most of the documentation but the warranty.
Very often issues with Lenox P506640-01 begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Air Conditioner Lenox P506640-01 is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Air Conditioner on our side using links below.
Lenox P506640-01 Installation Instructions
43 pages 1.19 Mb
*2P1210* *P506640-01*RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE NOTICE TO INSTALLERBRAZING LINE SET TO SERVICE VALVES INSTALLATION INSTRUCTIONSElite Series XP16 Units 6 NOTICESPage 7 Figure 5. Placement, Slab Mounting and Stabilizing Unit Deck Top Mounting Elevated Slab Mounting using Feet Extenders Outside Unit Placement Slab Mounting at Ground Level 7 DETAIL A DETAIL BDETAIL C DETAIL D DETAIL E DETAIL F Roof Top Mounting 8 Removing and Installing Panels9 Line Set RequirementsS S S S S S10 Page 10REFRIGERANT LINE SET TRANSITION FROM VERTICAL TO HORIZONTAL Figure 7. Line Set Installation REFRIGERANT LINE SET INSTALLING HORIZONTAL RUNS REFRIGERANT LINE SET INSTALLING VERTICAL RUNS (NEW CONSTRUCTION SHOWN) 11 Brazing Connections12 Page 12ATTACH THE MANIFOLD GAUGE SET FOR BRAZING LIQUID AND SUCTION / VAPOR LINE SERVICE VALVES CUT AND DEBUR CAP AND CORE REMOVALRemove service cap and core from both the suction / vapor and liquid line service ports. Figure 8. Brazing Procedures Page 14 Indoor Refrigerant Metering Device Removal and Flushing Line Set and Indoor CoilFigure 10. Removing Indoor Refrigerate Metering Device and Flushing Procedures TYPICAL EXISTING FIXED ORIFICE REMOVAL PROCEDURE (UNCASED COIL SHOWN) TYPICAL EXISTING EXPANSION VALVE REMOVAL PROCEDURE (UNCASED COIL SHOWN) 1CONNECT GAUGES AND EQUIPMENT FOR FLUSHING PROCEDURE OR 14 1A2 1B 17 1 2S S S S 18 Electrical ConnectionsPage 19 LOW VOLTAGE CONNECTIONS 19 A BC DHIGH VOLTAGE POWER SUPPLY CONNECTIONS 20 Page 20Figure 14. Typical Field Wiring Heat Pump Application with CBX32MV or CBX40UHV 23 Unit StartUpService and Weigh In Refrigerant for Outdoor Units Delivered Void of Charge 24 WEIGHIN CHARGINGPage 25 CONNECTIONS FOR OPTIMIZING SYSTEM CHARGE Figure 22. Heat Pump Cooling Cycle 25 GAUGE SET39 TEST
Also you can find more Lenox manuals or manuals for other Household Appliance.