Mocomtech CDM-570L manuals
Computer Equipment > Modem
When we buy new device such as Mocomtech CDM-570L we often through away most of the documentation but the warranty.
Very often issues with Mocomtech CDM-570L begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Modem Mocomtech CDM-570L is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Modem on our side using links below.
Mocomtech CDM-570L Specifications
452 pages 6.94 Mb
CDM-570/570L 3 CDM-570/570L Satellite Modem Installation and Operation Manual Addendum A 5 CDM/CDD NMCS Protocol 9 NMCS Protocol 79 CDM-570/570L Installation and Operation Manual 81 Table of Contents 91 Figures 92 Tables 93 Preface 99 Chapter 1. INTRODUCTION 107 Chapter 2. INSTALLATION 111 Chapter 3. FUNCTIONAL DESCRIPTION 113 Chapter 4. PHYSICAL DESCRIPTION 119 Chapter 5. CONNECTOR PINOUTS 125 Chapter 6. FRONT PANEL OPERATION 6.1 INTRODUCTION 129 6.2 OPENING SCREEN 6.3 MAIN SELECT MENU 130 6.4 CONFIG CONFIG: Remote All Tx Rx Frame Intfc Ref Mask ODU 131 6.5 (CONFIG) REMCONT (Remote control) 6.5.1 (CONFIG, REMOTE) SERIAL (CONFIG, REMOTE, SERIAL, INTERFACE) (CONFIG, REM, SERIAL, INTFC, ADDR) RS485 BUS ADDRESS 132 (CONFIG, REM, SERIAL, BAUD RATE) 6.5.2 (CONFIG, REMOTE) ETHERNET (CONFIG, REMOTE, ETHERNET) GATEWAY (CONFIG, REMOTE, ETHERNET) ADDRESS 133 (CONFIG, REMOTE, ETHERNET) MAC (CONFIG, REMOTE, ETHERNET) SNMP (CONFIG, REMOTE, ETHERNET, SNMP) Communities 134 (CONFIG, REMOTE, ETHERNET, SNMP) Traps 135 6.6 (CONFIG) ALL 6.7 (CONFIG) TX (Transmit) Tx:FEC Mod Code Data Frq On/Off Pwr Scram Clk Inv 136 6.7.1 (CONFIG, TX) FEC TYPE Tx FEC: Viterbi Vit+RS TCM+RS TPC LDPC Uncoded 137 6.7.2 (CONFIG, TX) MODULATION 6.7.3 (CONFIG, TX) CODE RATE Modulation: BPSK QPSK OQPSK 8-PSK 16-QAM 8-QAM Tx Code Rate: 5/16 21/44 1/2 2/3 3/4 7/8 0.95 Unc 138 6.7.4 (CONFIG, TX) DATA RATE Tx Dat Rate:5000.000kbps 3000.000ksym ( , ,ENT) 139 6.7.5 (CONFIG, TX) FREQUENCY 6.7.6 (CONFIG, TX) ON/OFF 140 6.7.7 (CONFIG, TX) POWER (CONFIG, TX, PWR, MODE) MANUAL Tx Output Power Level: -03.9 dBm ( , ENT) Warning! AUPC needs Framed Mode (ENT or CLR) Output Power Level Mode: Manual AUPC ( ,ENTER) 141 (CONFIG, TX, PWR, MODE) AUPC (CONFIG, TX, PWR, MODE, AUPC) TARGET EbNo (CONFIG, TX, PWR, MODE, AUPC) MAX RANGE (CONFIG, TX, PWR, MODE, AUPC) ALARM (CONFIG, TX, PWR, MODE, AUPC) DEMOD-UNLOCK 142 6.7.8 (CONFIG, TX) SCRAMBLING 6.7.9 (CONFIG, TX) CLOCKING Tx Scrambling:Default-On IESS-315-On Off ( ,ENT) Tx Clocking Mode: Int Ext Loop-Timed ( ,ENT) 143 6.7.10 (CONFIG, TX) INVERSION FUNCTIONS (CONFIG, TX, INV) SPECTRUM (CONFIG, TX, INV) DATA 144 6.8 (CONFIG) RX (Receive) Rx:FEC Dem Code Data Frq Acq Descram Buf Inv EbNo 145 6.8.1 (CONFIG, RX) FEC TYPE Rx FEC: Viterbi Vit+RS TCM+RS TPC LDPC Uncoded 146 6.8.2 (CONFIG , RX) DEMODULA TION6.8.3 (CONFIG, RX) CODE RATE Demodulation: BPSK QPSK OQPSK 8-PSK 8-QAM 16-QAM Rx Code Rate: 5/16 21/44 1/2 2/3 3/4 7/8 0.95 Unc 147 6.8.4 (CONFIG, RX) DATA RATE Rx Dat Rate:5000.000kbps 2500.000ksym ( , ,ENT) 148 6.8.5 (CONFIG, RX) FREQUENCY 6.8.6 (CONFIG, RX) ACQ 149 6.8.7 (CONFIG, RX) DESCRAMBLING Descrambling: Default-On IESS-315-On Off ( ,ENT) 150 6.8.8 (CONFIG, RX) BUFFER 6.8.9 (CONFIG, RX) INVERSION FUNCTIONS Timing Mode)( , ENTER) (13.1ms) ( , ENTER) Rx Inversion functions: Spectrum Data ( ,ENT) 151 6.8.10 (CONFIG, RX) Eb/No 6.9 (CONFIG) FRAME (Framing Mode) 152 6.9.1 (CONFIG, FRAME) UNFRAMED 6.9.2 (CONFIG, FRAME) EDMAC or EDMAC-2 (CONFIG, FRAME, FRAMED EDMAC+AUPC, MODE) 154 6.10 (CONFIG) INTERFACE 156 6.11 (CONFIG) REFERENCE 157 6.12 (CONFIG) MASK 159 6.13 (CONFIG) ODU (CDM-570L ONLY) 6.13.1 (CONFIG, ODU) BUC ODU (Outdoor Unit): BUC LNB ( ,ENTER) BUC: M&C-FSK DC-Power 10MHz Alarm LO Mix ( ) 160 (CONFIG, ODU, BUC) M&C-FSK (CONFIG, ODU, BUC, M&C-FSK) FSK-Comms (CONFIG, ODU, BUC, M&C-FSK) Address BUC M&C(FSK): FSK-Comms Address Tx-On/Off ( ) BUC M&C FSK Comms: On Off ( ,ENTER) BUC FSK Address: 01 ( ,ENTER) 161 (CONFIG, ODU, BUC, M&C-FSK) TX-ON/OFF (CONFIG, ODU, BUC) DC-POWER (CONFIG, ODU, BUC) 10MHz (CONFIG, ODU, BUC) ALARM 162 (CONFIG, ODU, BUC) LO BUC Current Alarm Upper Limit:1200mA ( , ,ENT) BUC Current Alarm Lower Limit:1200mA ( , ,ENT) BUC LO Frequency: 12000 MHz ( , ,ENTER) 163 (CONFIG, ODU, BUC) MIX 6.13.2 (CONFIG, ODU) LNB (CONFIG, ODU, LNB) VOLTAGE BUC Frequency Mix: High-Side Low-Side ( ) LNB: DC-Voltage 10MHz Alarm LO Mix ( , ENT) LNB DC Supply Voltage: 13 volts ( ,ENTER) 164 (CONFIG, ODU, LNB) 10MHz (CONFIG, ODU, LNB) ALARM 165 (CONFIG, ODU, LNB) LO (CONFIG, ODU, LNB) MIX LNB Frequency Mix: High-Side Low-Side ( ) LNB LO Frequency: 12000 MHz ( , ,ENTER) 166 6.14 MONIT (Monitor) 6.14.1 (MONIT) ALARMS (MON, ALARMS) UNIT (Unit alarms) (MON, ALARMS) RECEIVE (Receive Traffic Status) 167 (MON, ALARMS) TRANSMIT (Transmit Traffic Status) (MON, ALARMS) ODU (Outdoor Unit alarms) Tx Traffic: No Tx Clock from Terrestrial (ENT) ODU Alarms: BUC Current Over Limit (ENT) 168 6.14.2 (MONIT) RX-PARAMS (Receive Parameters) EbNo=05.7dB BER=3.4E-9 F=+11.7k Buf=50 RSL=-64 Demod: Not Locked RSL=-64 169 6.14.3 (MONIT) EVENT-LOG (STORED EVENTS) (MON, EVENTS) VIEW 170 6.14.4 (MONIT) STATS (Link Statistics) (MONIT, STATS) VIEW Link Statistics: View Clear-All Config( ,ENT) Sta198:02/11/02 10:37:32 16.0, 16.0, 9.0, 9.0( ) 171 (MONIT, STATS) CLEAR (MONIT, STATS) CONFIGURE Stats Logging Interval: Disabled ( ,ENTER) Stats Logging Interval: 30 minutes ( ,ENTER) Clear all Stored Stats? No Yes ( , ENTER) 172 6.14.5 (MONIT) AUPC 6.14.6 (MONIT) ODU 174 6.15 TEST TEST: Norm IF> Dig> I/O> RF> Tx-CW Tx-1,0( ,ENT) 176 6.16 INFO (Information) 6.16.1 (INFO) ALL 6.16.2 (INFO) TX (Transmit information) INFO:All Tx Rx Buf Frame Intfc Rem Msk Ref ID 1:1 Tx:1140.000 5000.000 TUR 8P 0.95 S EXT -20.0 ON I 177 6.16.3 (INFO) RX (Receive information) 6.16.4 (INFO) BUFF (Buffer information) Buffer: Enabled (Tx=Rx) Size:+/-04096 bits (ENT) Rx:1140.000 5000.000 TUR 8P 0.95 D BUF +/-32k I 178 6.16.5 (INFO) FRAME (Framing and EDMAC information) 6.16.6 (INFO) INTFC (Interface information) 179 6.16.7 (INFO) REMCONT (Remote Control information) 6.16.8 (INFO) MASK (Alarm mask information) 6.16.9 (INFO) REF (Frequency Reference) 180 6.16.10 (INFO) ID (Circuit ID) 6.16.11 (INFO) 1:1 (1:1 Redundancy information) 6.17 SAVE/LOAD 6.17.1 (SAVE/LOAD) SAVE 181 6.17.2 (SAVE/LOAD) LOAD 182 6.18 UTILITY 6.18.1 (UTIL) BUFFER (Buffer re-center) 6.18.2 (UTIL) CLOCK (Set real-time clock) 183 6.18.3 (UTIL) REF (Reference) (UTIL, REF) ADJUST (UTIL, REF) WARM-UP DELAY 185 6.18.4 (UTIL) ID (Circuit ID) 6.18.5 (UTIL) 1:1 (Manual 1:1 switchover) 6.18.6 (UTIL) VFD (VFD Display brightness) 186 6.18.7 (UTIL) FIRMWARE 187 6.18.8 (UTIL) FAST (FAST code options) 191 Chapter 7. FORWARD ERROR CORRECTION OPTIONS 211 Chapter 8. OFFSET QPSK OPERATION 213 Chapter 9. CLOCKING MODES 9.1 Transmit Clocking 9.1.1 Internal Clock 214 9.1.2 Tx Terrestrial 9.1.3 Rx Loop-Timed, Rx=Tx 9.1.4 Rx Loop-Timed, Rx<>Tx (Asymmetric Loop Timing) 219 Chapter 10. EDMAC CHANNEL 223 Chapter 11. AUTOMATIC UPLINK POWER CONTROL 227 Chapter 12. SUMMARY OF SPECIFICATIONS 235 Chapter 13. SERIAL REMOTE CONTROL 267 Chapter 14. ETHERNET MANAGEMENT (Base Modem) 277 Chapter 15. IP MODULE ETHERNET INTERFACE OVERVIEW 293 Chapter 16. TYPICAL IP MODULE OPERATIONAL SETUPS 301 Chapter 17. IP MODULE - CLI AND TELNET OPERATION 387 Chapter 19. SNMP INTERFACE 401 Appendix C. FAST ACTIVATION PROCEDURE 405 Appendix D. QUICK-START GUIDE 419 Appendix E. FLASH UPGRADING 425 Appendix F. ODU OPERATION F.1 Introduction 426 F.2 ODU Remote Control Address Setup F.3 MENU TREES F.3.1 MODEM MAIN MENU 427 F.3.2 ODU F.3.3 CSAT Transceiver Menus F.3.3.1 (ODU,ENABLE) System Type F.3.3.2 (ODU,ENABLE) 1:1 428 F.3.3.3 (ODU,ENABLE,1:1) RED-BOX (Redundancy Controller Box) F.3.3.4 (ODU,ENABLE,1:1,RED BOX) ONLINE F.3.3.5 (ODU,ENABLE,1:1,RED BOX) MODE F.3.3.6 (ODU,ENABLE,1:1,RED BOX) SWITCHES F.3.3.7 (ODU,ENABLE,1:1,RED BOX) VOLTAGES 442 F.3.4 KST2000A/B Menus F.3.4.1 (ODU,ENABLE) Selections F.3.4.2 (ODU,ENABLE) CONFIG (Configuration) F.3.4.3 (ODU,ENABLE,CONFIG) TRANSMITTER F.3.4.4 (ODU,ENABLE,CONFIG,TRANSMITTER) FREQUENCY 443 F.3.4.5 (ODU,ENABLE, CONFIG,TRANSMITTER) ATTEN (Attenuation) F.3.4.6 (ODU,ENABLE,CONFIG,TRANSMITTER) OUTPUT F.3.4.7 (ODU,ENABLE,CONFIG,TRANSMITTER) HPA F.3.4.8 (ODU, ENABLE,CONFIG,TRANSMITTER) STATE F.3.4.9 (ODU,ENABLE,CONFIG, TRANSMITTER) FAULT-LOGIC 444 F.3.4.10 (ODU,ENABLE, CONFIG) RECEIVER F.3.4.11 (ODU,ENABLE, CONFIG,RECEIVER) FREQUENCY F.3.4.12 (ODU,ENABLE, CONFIG,RECEIVER) ATTEN (Attenuation) F.3.4.13 (ODU,ENABLE, CONFIG,RECEIVER) LNA / LNB 445 F.3.4.14 (ODU,ENABLE, CONFIG,RECEIVER,LNA) STATE F.3.4.15 (ODU,ENABLE, CONFIG,RECEIVER,LNA) FAULT-LOGIC F.3.4.16 (ODU,ENABLE, CONFIG,RECEIVER,LNA) CAL (Calibrate) F.3.4.17 (ODU,ENABLE, CONFIG, RECEIVER, LNB) BAND F.3.4.18 (ODU,ENABLE, CONFIG) MISCELLANEOUS 446 F.3.4.19 (ODU,ENABLE,CONFIG,MISCELLANEOUS) AGC (Auto Gain Control) F.3.4.20 (ODU,ENABLE,CONFIG,MISCELLANEOUS) REF-ADJUST F.3.4.21 (ODU,ENABLE) INFO (Information) F.3.4.22 (ODU,ENABLE,INFO) TRANSMITTER F.3.4.23 (ODU,ENABLE, INFO) RECEIVER 448 F.3.5 (ODU,ENABLE) STATUS 449 Appendix G. GPS MODE
Also you can find more Mocomtech manuals or manuals for other Computer Equipment.