Filename: T_ERRATA 1

Errata F

Comtech EF Data Documentation Update
Subject: Revised AUPC Parameters in Remote Control
Date: October 26, 2006
Document: CDM-570/570L Satellite Modem with Optional IP Module,
Installation and Operation Manual, Rev. 4, dated April 12, 2006
Part Number: MN/CDM-570L.EF4
Collating Instructions: Attach this page to page 6-17

Comments:

The following changes affects the values shown on page 6-17 and 13-10.

Change Specifics:

Change to APU Target Eb/No Parameter

Since Revision 4 of the CDM-570/570(L) Manual was published, the range of the value of target
Eb/No has been increased. Effective in firmware version 1.5.3 and subsequent:
Previously the maximum value was 9.9 dB
New maximum value is 14.9 dB
This affects the front panel and the remote control; refer to the remote control command table
(Errata G) for more detail.