Manuals / Brands / Computer Equipment / Modem / Mocomtech / Computer Equipment / Modem

Mocomtech CDM-570, CDM-570L specifications - page 2

1 452
Download 452 pages, 6.94 Mb
Contents
Main CDM-570/570L Page CDM-570/570L Satellite Modem Installation and Operation Manual Addendum A Page CDM/CDD NMCS Protocol Rev 1.0 Revision History Page Table of Contents 1.0 Introduction 2.0 Architecture NMCS Protocol 3.0 Introduction 3.1 Telnet interface 3.2 Basic Protocol 3.3 Command Structure Controller-to-target: 3.3.1 Start Of Packet 3.3.2 Address 3.3.3 Instruction Code 3.3.4 Instruction Code Qualifier 3.3.4.1 Controller to Target 3.3.4.2 Target to Controller 3.3.5 Message Arguments 3.3.6 Table Support Qualifier 3.3.6.1 Index 3.3.6.2 Argument lists 3.3.7 End Of Packet 3.4 Modem Commands Page 3.4.1 IP Commands 3.4.1.1 Admin Commands Page Page Page Page Page Page Page 3.4.2 Interface Commands Page 3.4.3 QoS Commands Page Page Page 3.4.4 Protocol Commands Page Page 3.4.6 Operations and Maintenance Commands Page Page Page 3.4.7 Redundancy Commands 3.4.8 Routing Commands Page Page 3.4.9 Statistics Commands 3.4.9.1 Wan Stats Page 3.4.9.2 IP Stats Page Page 3.4.9.3 Ethernet Stats Page 3.4.9.4 QoS Stats 3.5 PARAM Files This section gives more detail about the possible values of various parameters in PARAM file. Page Page Page Page Page Page Errata A Page Errata B Page Errata C Page Errata D Comments: Change Specifics: 12.2 Demodulator Page Errata E Subject: Changed Figure 7-5, TPC Curve for Rate 7/8 Comtech Turbo Product Codec Rate 7/8 QPSK/OQPSK, 8-PSK and 16-QAM Figure 7-5. Comtech EF Data Turbo Product Codec Rate 7/8 QPSK/OQPSK, 8-PSK AND 16-QAM Errata F Comments: Change Specifics: Change to APU Target Eb/No Parameter Page Errata G Page Errata H Subject: Revised Options Table Page Errata J 25 PIN D TYPE MALE CDM-570LEIA530TOV.35DCECONVERSIONCABLE 34 PIN WINCHESTER FEMALE FEMALE 25 PIN D MALE LENGTH = TBD Errata K Page Errata L Subject: Revised BUC Reference Page CDM-570/570L Installation and Operation Manual Page Table of Contents Page Page Page Page Page Page Page Page Page Figures Tables Preface Customer Service About this Manual Conventions and References Metric Conversion Cautions and Warnings Recommended Standard Designations Reporting Comments or Suggestions Concerning this Manual Electrical Safety Fuses Environmental Installation ~ Telecommunications Terminal Equipment Directive EMC (Electromagnetic Compatibility) Warranty Policy Limitations of Warranty Exclusive Remedies Disclaimer Chapter 1. INTRODUCTION 1.1 Introduction 1.1.1 EDMAC 1.1.2 AUPC 1.1.3 Software Flash Upgrading 1.1.4 Verification 1.1.5 Data Interfaces 1.2 Major Assemblies 1.3 FAST Options and Hardware Options 1.3.1 FAST Accessible Options 1.3.2 FAST System Theory 1.3.3 Implementation 1.3.4 Hardware Options 1.3.5 Supporting Hardware and Software 1.4 Compatibility 1.5 New in this release Page Page Chapter 2. INSTALLATION 2.1 Unpacking 2.2 Mounting 2.2.1 Optional Rear-Mounting Installation Bracket Page 2.3 Configuration 2.4 Select Internal IF Loop 2.5 Connect External Cables Chapter 3. FUNCTIONAL DESCRIPTION Page Chapter 4. PHYSICAL DESCRIPTION 4.1 Introduction 4.2 Front Panel 4.3 Rear Panel 4.3.1 IEC Line Input Connector 4.3.2 Rx and Tx IF Connectors 4.3.3 Data Interface Connector Page Page 4.4 Dimensional Envelope Chapter 5. CONNECTOR PINOUTS 5.1 Connector Overview 5.2 Data Interface Connector THE MODEM IS ALWAYS ASSUMED TO BE DCE. 5.3 Balanced G.703 Interface Connector 5.4 Remote Control Interface C o nnector 5.5 BNC Connectors 5.6 Unit Alarms 5.7 1:1 Control Connector 5.8 Async-Serial Console (Optional IP Module Only) 5.9 Ethernet Interface Connectors (Traffic and M&C) 5.10 AC Power Connect or 5.11 Ground Connector Chapter 6. FRONT PANEL OPERATION 6.1 INTRODUCTION Page Page Page 6.2 OPENING SCREEN 6.3 MAIN SELECT MENU 6.4 CONFIG CONFIG: Remote All Tx Rx Frame Intfc Ref Mask ODU 6.5 (CONFIG) REMCONT (Remote control) 6.5.1 (CONFIG, REMOTE) SERIAL (CONFIG, REMOTE, SERIAL, INTERFACE) (CONFIG, REM, SERIAL, INTFC, ADDR) RS485 BUS ADDRESS (CONFIG, REM, SERIAL, BAUD RATE) 6.5.2 (CONFIG, REMOTE) ETHERNET (CONFIG, REMOTE, ETHERNET) GATEWAY (CONFIG, REMOTE, ETHERNET) ADDRESS (CONFIG, REMOTE, ETHERNET) MAC (CONFIG, REMOTE, ETHERNET) SNMP (CONFIG, REMOTE, ETHERNET, SNMP) Communities (CONFIG, REMOTE, ETHERNET, SNMP) Traps 6.6 (CONFIG) ALL 6.7 (CONFIG) TX (Transmit) Tx:FEC Mod Code Data Frq On/Off Pwr Scram Clk Inv 6.7.1 (CONFIG, TX) FEC TYPE Tx FEC: Viterbi Vit+RS TCM+RS TPC LDPC Uncoded 6.7.2 (CONFIG, TX) MODULATION 6.7.3 (CONFIG, TX) CODE RATE Modulation: BPSK QPSK OQPSK 8-PSK 16-QAM 8-QAM Tx Code Rate: 5/16 21/44 1/2 2/3 3/4 7/8 0.95 Unc 6.7.4 (CONFIG, TX) DATA RATE Tx Dat Rate:5000.000kbps 3000.000ksym ( , ,ENT) 6.7.5 (CONFIG, TX) FREQUENCY 6.7.6 (CONFIG, TX) ON/OFF 6.7.7 (CONFIG, TX) POWER (CONFIG, TX, PWR, MODE) MANUAL Tx Output Power Level: -03.9 dBm ( , ENT) Warning! AUPC needs Framed Mode (ENT or CLR) Output Power Level Mode: Manual AUPC ( ,ENTER) (CONFIG, TX, PWR, MODE) AUPC (CONFIG, TX, PWR, MODE, AUPC) TARGET EbNo (CONFIG, TX, PWR, MODE, AUPC) MAX RANGE (CONFIG, TX, PWR, MODE, AUPC) ALARM (CONFIG, TX, PWR, MODE, AUPC) DEMOD-UNLOCK 6.7.8 (CONFIG, TX) SCRAMBLING 6.7.9 (CONFIG, TX) CLOCKING Tx Scrambling:Default-On IESS-315-On Off ( ,ENT) Tx Clocking Mode: Int Ext Loop-Timed ( ,ENT) 6.7.10 (CONFIG, TX) INVERSION FUNCTIONS (CONFIG, TX, INV) SPECTRUM (CONFIG, TX, INV) DATA 6.8 (CONFIG) RX (Receive) Rx:FEC Dem Code Data Frq Acq Descram Buf Inv EbNo 6.8.1 (CONFIG, RX) FEC TYPE Rx FEC: Viterbi Vit+RS TCM+RS TPC LDPC Uncoded 6.8.2 (CONFIG , RX) DEMODULA TION 6.8.3 (CONFIG, RX) CODE RATE Demodulation: BPSK QPSK OQPSK 8-PSK 8-QAM 16-QAM Rx Code Rate: 5/16 21/44 1/2 2/3 3/4 7/8 0.95 Unc 6.8.4 (CONFIG, RX) DATA RATE Rx Dat Rate:5000.000kbps 2500.000ksym ( , ,ENT) 6.8.5 (CONFIG, RX) FREQUENCY 6.8.6 (CONFIG, RX) ACQ 6.8.7 (CONFIG, RX) DESCRAMBLING Descrambling: Default-On IESS-315-On Off ( ,ENT) 6.8.8 (CONFIG, RX) BUFFER 6.8.9 (CONFIG, RX) INVERSION FUNCTIONS Timing Mode)( , ENTER) (13.1ms) ( , ENTER) Rx Inversion functions: Spectrum Data ( ,ENT) 6.8.10 (CONFIG, RX) Eb/No 6.9 (CONFIG) FRAME (Framing Mode) 6.9.1 (CONFIG, FRAME) UNFRAMED 6.9.2 (CONFIG, FRAME) EDMAC or EDMAC-2 (CONFIG, FRAME, FRAMED EDMAC+AUPC, MODE) EDMAC Mode: Master Slave ( ,ENTER) Framing mix: AUPC-Only AUPC+EDMAC ( ,ENTER) Address of this Slave Unit: 0241 ( , ,ENT) Distant-end Base Address 0240 ( , ,ENTER) 6.10 (CONFIG) INTERFACE T1 Line Code (B8ZS): On Off(AMI) ( ,ENTER) T1 Line Length: 000-133 feet ( ,ENTER) E1 Line Code (HDB3): On Off ( ,ENTER) 6.11 (CONFIG) REFERENCE 6.12 (CONFIG) MASK Reference Alarm: Active Masked ( ,ENT) BUC Alarm: Active Masked ( ,ENT) LNB Alarm: Active Masked ( ,ENT) 6.13 (CONFIG) ODU (CDM-570L ONLY) 6.13.1 (CONFIG, ODU) BUC ODU (Outdoor Unit): BUC LNB ( ,ENTER) BUC: M&C-FSK DC-Power 10MHz Alarm LO Mix ( ) (CONFIG, ODU, BUC) M&C-FSK (CONFIG, ODU, BUC, M&C-FSK) FSK-Comms (CONFIG, ODU, BUC, M&C-FSK) Address BUC M&C(FSK): FSK-Comms Address Tx-On/Off ( ) BUC M&C FSK Comms: On Off ( ,ENTER) (CONFIG, ODU, BUC, M&C-FSK) TX-ON/OFF (CONFIG, ODU, BUC) DC-POWER (CONFIG, ODU, BUC) 10MHz (CONFIG, ODU, BUC) ALARM (CONFIG, ODU, BUC) LO BUC Current Alarm Upper Limit:1200mA ( , ,ENT) BUC Current Alarm Lower Limit:1200mA ( , ,ENT) BUC LO Frequency: 12000 MHz ( , ,ENTER) (CONFIG, ODU, BUC) MIX 6.13.2 (CONFIG, ODU) LNB (CONFIG, ODU, LNB) VOLTAGE BUC Frequency Mix: High-Side Low-Side ( ) LNB: DC-Voltage 10MHz Alarm LO Mix ( , ENT) (CONFIG, ODU, LNB) 10MHz (CONFIG, ODU, LNB) ALARM (CONFIG, ODU, LNB) LO (CONFIG, ODU, LNB) MIX LNB Frequency Mix: High-Side Low-Side ( ) LNB LO Frequency: 12000 MHz ( , ,ENTER) 6.14 MONIT (Monitor) 6.14.1 (MONIT) ALARMS (MON, ALARMS) UNIT (Unit alarms) (MON, ALARMS) RECEIVE (Receive Traffic Status) (MON, ALARMS) TRANSMIT (Transmit Traffic Status) (MON, ALARMS) ODU (Outdoor Unit alarms) Tx Traffic: No Tx Clock from Terrestrial (ENT) ODU Alarms: BUC Current Over Limit (ENT) 6.14.2 (MONIT) RX-PARAMS (Receive Parameters) EbNo=05.7dB BER=3.4E-9 F=+11.7k Buf=50 RSL=-64 Demod: Not Locked RSL=-64 6.14.3 (MONIT) EVENT-LOG (STORED EVENTS) (MON, EVENTS) VIEW 6.14.4 (MONIT) STATS (Link Statistics) (MONIT, STATS) VIEW Link Statistics: View Clear-All Config( ,ENT) Sta198:02/11/02 10:37:32 16.0, 16.0, 9.0, 9.0( ) (MONIT, STATS) CLEAR (MONIT, STATS) CONFIGURE Stats Logging Interval: Disabled ( ,ENTER) Stats Logging Interval: 30 minutes ( ,ENTER) Clear all Stored Stats? No Yes ( , ENTER) 6.14.5 (MONIT) AUPC 6.14.6 (MONIT) ODU BUC:DC=47.8V,3.25A SW=05 T=+38C PLL=Flt Pwr=02.1W 6.15 TEST TEST: Norm IF> Dig> I/O> RF> Tx-CW Tx-1,0( ,ENT) Page 6.16 INFO (Information) 6.16.1 (INFO) ALL 6.16.2 (INFO) TX (Transmit information) INFO:All Tx Rx Buf Frame Intfc Rem Msk Ref ID 1:1 6.16.3 (INFO) RX (Receive information) 6.16.4 (INFO) BUFF (Buffer information) Buffer: Enabled (Tx=Rx) Size:+/-04096 bits (ENT) Rx:1140.000 5000.000 TUR 8P 0.95 D BUF +/-32k I 6.16.5 (INFO) FRAME (Framing and EDMAC information) 6.16.6 (INFO) INTFC (Interface information) 6.16.7 (INFO) REMCONT (Remote Control information) 6.16.8 (INFO) MASK (Alarm mask information) 6.16.9 (INFO) REF (Frequency Reference) 6.16.10 (INFO) ID (Circuit ID) 6.16.11 (INFO) 1:1 (1:1 Redundancy information) 6.17 SAVE/LOAD 6.17.1 (SAVE/LOAD) SAVE 6.17.2 (SAVE/LOAD) LOAD 6.18 UTILITY 6.18.1 (UTIL) BUFFER (Buffer re-center) 6.18.2 (UTIL) CLOCK (Set real-time clock) 6.18.3 (UTIL) REF (Reference) (UTIL, REF) ADJUST (UTIL, REF) WARM-UP DELAY Internal 10 MHz Freq Ref Fine Adjust:+017( , ) Internal Freq Ref:Adjust Warm-up delay ( ,ENTER) Comtech CDM-570L Modem Ref Warming-up: 045 secs 6.18.4 (UTIL) ID (Circuit ID) 6.18.5 (UTIL) 1:1 (Manual 1:1 switchover) 6.18.6 (UTIL) VFD (VFD Display brightness) 6.18.7 (UTIL) FIRMWARE 6.18.8 (UTIL) FAST (FAST code options) View Options: 03 ( ) 150W BPSU Not Installed FAST Demo Mode: Off On 604800 seconds remain FAST Demo Mode: Off On Demo Period Expired Page Page Chapter 7. FORWARD ERROR CORRECTION OPTIONS 7.1 Introduction 7.2 Viterbi 7.3 Reed-Solomon Outer Codec (Hard war e Option) Page 7.4 Trellis Coding (requires 8-PSK/8-QAM FAST Option) 7.5 Turbo Product Codec (Hardware Option) 7.5.1 Introduction 7.5.2 TPC modes available in the CDM-570/570L 7.5.3 8-QAM Modulation 7.5.4 End-to-End Processing Delay 7.5.5 Comparison of all TPC Modes 7.6 Uncoded Operation (No FEC) 7.7 Rates above 2.5 Msymbols/sec Viterbi Decoding Vi ter b i with concatenated RS 220,200 Outer Code 8-PS K/ TCM Rate 2/ 3 Decoding, wi th 220, 200 RS O u ter Co d e Comtech Turbo Product Codec Rate 3/4 QPSK/OQPSK, 8-PSK and 16-QAM Comtech Turbo P roduct Codec Rate 7/8 QPSK/OQPSK, 8-PSK and 16-QAM Comtech Turbo Product Codec Rate 21/44 QPSK/OQPSK Rate 0.95 QPSK/OQPSK and 8-PSK Comtech Turbo P roduct Codec Rate 21/44 BP SK Rate 5/16 BPSK Comtech Turbo Product Code c Rate 3/4 8-QAM Rate 0.95 8-QAM Comtech Turbo Product Code c Rate 7/8 8-QAM 16-QAM Viterbi, Rate 3/4 and Rate 7/8 wi th 220, 200 RS Ou ter Cod e Differential Encoding - No FEC, n o scrambling Chapter 8. OFFSET QPSK OPERATION Page Chapter 9. CLOCKING MODES 9.1 Transmit Clocking 9.1.1 Internal Clock 9.1.2 Tx Terrestrial 9.1.3 Rx Loop-Timed, Rx=Tx 9.1.4 Rx Loop-Timed, Rx<>Tx (Asymmetric Loop Timing) Page Page Page Page Chapter 10. EDMAC CHANNEL 10.1 Theory Of Operation 10.2 M&C Connection 10.3 Setup Summary Page Chapter 11. AUTOMATIC UPLINK POWER CONTROL 11.1 Introduction 11.2 Setting AUPC Parameters 11.2.1 Target Eb/No 11.2.2 Max Range 11.2.3 Alarm 11.2.4 Demod Unlock 11.3 Compensation Rate 11.4 Monitoring Chapter 12. SUMMARY OF SPECIFICATIONS 12.1 Modulator Page 12.2 Demodulator Comtech EF Data CDM-570L Transmit Power Spectral Density, referred to symbol rate IMPORTANT NOTE: 12.3 Automatic Uplink Power Control 12.4 Data and Miscellaneous Interfaces 12.5 Data Rate Ranges FEC Type Modulation Code Rate Data Rate Range EDMAC limited? 12.6 Miscellaneous 12.7 Approvals CE as follo w s: FCC Page Chapter 13. SERIAL REMOTE CONTROL 13.1 Introduction 13.2 RS-485 13.3 RS-232 13.4 Basic Protocol 13.5 Packet Structure 13.5.1 Start Of Packet 13.5.2 Address 13.5.3 Instruction Code 13.5.4 Instruction Code Qualifier Page 13.5.5 Message Arguments 13.5.6 End Of Packet riority parameter can override any of the parameters of lower priority. p Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Chapter 14. ETHERNET MANAGEMENT (Base Modem) 14.1 Introduction 14.2 Ethernet Management Int erface Protocols 14.3 We b Server (HTTP) Interface 14.3.1 We b Server Menu Tree Table 14-1. Web Server Menu Tree 14.4 SNMP Interface 14.4.1 Management Information Base (MIB) Files 14.4.2 SNMP Community Strings 14.4.3 SNMP Traps 14.5 Telnet Interface Page Page Page Page Chapter 15. IP MODULE ETHERNET INTERFACE OVERVIEW 15.1 Introduction 15.2 Major Assemblies 15.3 IP Module Standard Features 15.3.1 10/100BaseT Ethernet Interface 15.3.2 Powerful Network Manage m ent 15.3.3 Remote softwar e/firmware upgrade via FTP Page 15.3.10 easyConnect Mode 15.3.11 easyConnect Operation 15.4 IP Module Optional Features 15.4.1 3xDES Encryption with Ability to Change Keys 15.4.2 IP Header Compression 15.4.3 Payload Compression 15.4.3.1 ADLC vs. LZS Compression Comparison 15.4.4 Quality of Service 15.4.4.1 Maximum Bandwidth/Priority QoS Mode Page Page 15.4.4.2 Minimum/Maximum Bandwidth QoS Mode 15.4.4.3 DiffServ QoS Mode Page 15.4.5 CDM-570/570L IP Module Demo Mode 15.5 IP Module Specifications Page Chapter 16. TYPICAL IP MODULE OPERATIONAL SETUPS 16.1 Overview 16.2 Modem Compatibility 16.3 IP Module Working Modes 16.3.1 easyConnect Working Mode 16.3.2 Router Working Mode Point-to-Point 16.3.3 Router Working Mode Point-to-MultiPoint Page Page Chapter 17. IP MODULE - CLI AND TELNET OPERATION 17.1 Overview Page 17.2 Main Menu Page 17.2.1 Administration Page Page 17.2.1.1 Name/Password Confi gurati on Pa ge 17.2.1.2 Access Lists Page The Access Lists page contains the following options/fields: 17.2.1.3 Feature Configurati on Pa ge Page 17.2.1.4 3xDES Encrypt Configuration Page enter 17.2.1.5 SMTP Configuration Page 17.2.1.6 SNMP Configuration Page Page 17.2.1.7 Working Mode 17.2.1.8 easyConnect Multicast Option 17.2.1.9 Header/Payload Compression Refresh Rate 17.2.1.10 Payload Compression Refresh R ate 17.2.1.11 Telnet Timeout 17.2.2 Interface Configuration Page 17.2.2.1 Ethernet Interface Page The Fast Ethernet Interface page is activated from the Interface Configuration page. The Ethernet Interface page contains the following options/fields: 17.2.2.2 Satellite/HDLC Interface Page 17.2.2.3 Receiver HDLC Addresses Page 17.2.3 QoS (Quality of Service) Configuration Page 17.2.3.1 QoS Configuration Page Max/Priority Mode Page Page Page 17.2.3.2 16.2.4.1 QoS Configuration Page Min/Max Mode 17.2.3.3 16.2.4.2 QoS Configuration Page DiffServ Mode 17.2.4 Route Table Configuration Page The Route Table Configuration page contains the following options/fields: M IP M Page Page 17.2.5 Protocol Configuration Page 17.2.5.1 IGMP Information Page IP M Page Page 17.2.5.2 ARP Table Utilities Page Page 17.2.6 Vipersat Configuration Page The Vipersat Configuration page is activated from the Main Menu page. The Vipersat Configuration page contains the following options/fields: 17.2.7 Satellite Modem Page 17.2.8 Configuration Page 17.2.8.1 Transmit Modem Configurati on Page Page 17.2.8.2 Receive Modem Configuration Page Page 17.2.8.3 Framing Mode Configuration 17.2.8.4 Data Interface Configuration 17.2.8.5 Reference Configuration Page 17.2.8.6 Alarm Mask Configuration 17.2.8.7 Block Up Converter (BUC) Configuration 17.2.8.8 Low Noise Block Converter (LNB) Configuration 17.2.9 Operations and Mainte na nc e Page The Operations and Maintenance page is activated from the Main Menu page. The Operations and Maintenance page contains the following options/fields: M 17.2.9.1 Unit Information Page 17.2.9.2 Statistics Page Page Page Page Page 17.2.9.2.2 QoS Statistics Page 17.2.9.2.3 Ethernet Statistics Page Page 17.2.9.2.4 WAN Statistics Page 17.2.9.2.5 Compression Statistics Page 17.2.9.3 Event Log Page Page 17.2.9.4 Database Operations Page 17.2.9.5 Diagnostics Page 17.2.10 Telnet - Logout Option Page Page HTTP Login Access Levels are defined as follows: 18.1.1 We b Server Menu Tree Table 18-1. IP Module Web Server Menu Tree 18.2 Home Pages 18.2.1 Home Page 18.2.2 Contact Information 18.2.3 Support IP Module . The user can also select to automatically attach the IP Module 18.2.4 Logoff Page Chapter 19. SNMP INTERFACE 19.1 SNMP Interface 19.2 CDM-570/570L Management Information Base (MIB) Files Page 19.3 SNMP Community Strings 19.4 SNMP Traps 19.5 MIB-II 19.6 CDM-570/570L Private MIB Page Page Page Page PC 9 PIN SERIAL PORT TO CDM-570L RS232 REMOTE CONTROL PORT Page Page CDM-570/570L Satellite Modem with Optional IP Module Revision 4 Appendix B MN/CDM570L.IOM B3 Page Appendix C. FAST ACTIVATION PROCEDURE C.1 Introduction C.2 Activation Procedure C.2.1 Serial Number C.2.2 View currently installed feat ures C.2.3 Enter Access Codes FAST Configuration: Edit Code Demo Mode Edit 20 digit FAST Code: 00000000000000000000 ENT Configured Successfully (ENTER or CLEAR) C.2.4 Enable / Disable Demo Mode Page Appendix D. QUICK-START GUIDE D.1 Introduction D.1.1 Equipment List Following equipment is required: D.1.2 Equipment Setup D.1.3 Transmit and Receive IF Configuration D.1.4 Serial console port Command Line Interface (CLI) Configuration Page D.1.6 Restoring Factory Default Configuration D.2 easyConnect Point-to-Point System Configuration D.2.1 PC Configuration D.2.2 CDM-IP Configuration D.2.3 Setting IP Address(es) D.3 Router Mode Point-to-Point System Configuration D.3.1 PC Configuration D.3.2 Setting CDM-IP Modems to Router Mode Operation Perform the following steps on CDM-IP 1 D.3.3 Setting IP Address(es) D.3.4 Set IP Stack DES Select Key to ClearRoute Table Perform the following steps on CDM-IP 1 Perform the following steps on CDM-IP 2 Page D.4 Troubleshooting IP Module D.4.1 easyConnect Mode Troubleshooting easyConnect Mode Troubleshooting D.4.2 Router Mode Troubleshooting phymon_callback(): enet link change! link=1 phymon_callback(): enet link change! link=0 Appendix E. FLASH UPGRADING E.1 Ethernet FTP Upload Procedure Page Page E.2 Ethernet IP Module FTP Upload Procedure Page E.3 USB Procedure Appendix F. ODU OPERATION F.1 Introduction F.2 ODU Remote Control Address Setup F.3 MENU TREES F.3.1 MODEM MAIN MENU F.3.2 ODU F.3.3 CSAT Transceiver Menus F.3.3.1 (ODU,ENABLE) System Type F.3.3.2 (ODU,ENABLE) 1:1 F.3.3.3 (ODU,ENABLE,1:1) RED-BOX (Redundancy Controller Box) F.3.3.4 (ODU,ENABLE,1:1,RED BOX) ONLINE F.3.3.5 (ODU,ENABLE,1:1,RED BOX) MODE F.3.3.6 (ODU,ENABLE,1:1,RED BOX) SWITCHES F.3.3.7 (ODU,ENABLE,1:1,RED BOX) VOLTAGES Page Page Page Page Page Page Page Page Page Page Page Page Page F.3.4 KST2000A/B Menus F.3.4.1 (ODU,ENABLE) Selections F.3.4.2 (ODU,ENABLE) CONFIG (Configuration) F.3.4.3 (ODU,ENABLE,CONFIG) TRANSMITTER F.3.4.4 (ODU,ENABLE,CONFIG,TRANSMITTER) FREQUENCY F.3.4.5 (ODU,ENABLE, CONFIG,TRANSMITTER) ATTEN (Attenuation) F.3.4.6 (ODU,ENABLE,CONFIG,TRANSMITTER) OUTPUT F.3.4.7 (ODU,ENABLE,CONFIG,TRANSMITTER) HPA F.3.4.8 (ODU, ENABLE,CONFIG,TRANSMITTER) STATE F.3.4.9 (ODU,ENABLE,CONFIG, TRANSMITTER) FAULT-LOGIC F.3.4.10 (ODU,ENABLE, CONFIG) RECEIVER F.3.4.11 (ODU,ENABLE, CONFIG,RECEIVER) FREQUENCY F.3.4.12 (ODU,ENABLE, CONFIG,RECEIVER) ATTEN (Attenuation) F.3.4.13 (ODU,ENABLE, CONFIG,RECEIVER) LNA / LNB F.3.4.14 (ODU,ENABLE, CONFIG,RECEIVER,LNA) STATE F.3.4.15 (ODU,ENABLE, CONFIG,RECEIVER,LNA) FAULT-LOGIC F.3.4.16 (ODU,ENABLE, CONFIG,RECEIVER,LNA) CAL (Calibrate) F.3.4.17 (ODU,ENABLE, CONFIG, RECEIVER, LNB) BAND F.3.4.18 (ODU,ENABLE, CONFIG) MISCELLANEOUS F.3.4.19 (ODU,ENABLE,CONFIG,MISCELLANEOUS) AGC (Auto Gain Control) F.3.4.20 (ODU,ENABLE,CONFIG,MISCELLANEOUS) REF-ADJUST F.3.4.21 (ODU,ENABLE) INFO (Information) F.3.4.22 (ODU,ENABLE,INFO) TRANSMITTER F.3.4.23 (ODU,ENABLE, INFO) RECEIVER Page F.3.5 (ODU,ENABLE) STATUS Appendix G. GPS MODE G.1 Hardware Setup: G.2 Remote Commands: METRIC CONVERSIONS Units of Length Temperature Conversions Units of Weight 2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161