CDM-570/570L Satellite Modem with Optional IP Module Revision 4
Serial Remote Control MN/CDM570L.IOM
13–12
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Rx Frequency RFQ= 9 bytes Command or Query.
Rx Frequency
CDM-570L: 950 to 1950 MHz
CDM-570: 50 to 90 and 100 - 180 MHz
Resolution=100 Hz
Example: RFQ=0950.9872
Example: RFQ=0073.4528
RFQ=
RFQ?
RFQ*
RFQ#
RFQ? RFQ=xxxx.xxxx
(see description of
arguments)
Rx FEC Type RFT= 1 byte, value
of 0 thru 6
Command or Query.
Rx FEC Type, where:
0=None (uncoded – no FEC) with differential encoding ON
1=Viterbi
2=Viterbi + Reed-Solomon
3= Reserved – do not use
4= Reserved – do not use
5=TCM + Reed-Solomon
6=Turbo
7= TPC/LDPC (Future option)
Example: RFT=1 (which is Viterbi only)
RFT=
RFT?
RFT*
RFT#
RFT+
RFT? RFT=x
(same format
as command argument)
Rx Demod
type
RMD= 1 byte, value
of 0 thru 5
Command or Query.
Rx Demodulation, where:
0=BPSK
1=QPSK
2=OQPSK
3=8PSK
4=16QAM (Turbo or Viterbi + RS only)
5=8-QAM (Future option)
Depending on FEC type, not all of these selections will be valid.
All other codes are invalid.
Example: RMD=2 (selects OQPSK)
RMD=
RMD?
RMD*
RMD#
RMD+
RMD? RMD=x
(see description of
arguments)