Main
CDM-570/570L
Page
CDM-570/570L
Satellite Modem Installation and Operation Manual Addendum A
Page
CDM/CDD NMCS Protocol
Rev 1.0
Revision History
Page
Table of Contents
1.0 Introduction
2.0 Architecture
NMCS Protocol
3.0 Introduction
3.1 Telnet interface
3.2 Basic Protocol
3.3 Command Structure
Controller-to-target:
3.3.1 Start Of Packet
3.3.2 Address
3.3.3 Instruction Code
3.3.4 Instruction Code Qualifier
3.3.4.1 Controller to Target
3.3.4.2 Target to Controller
3.3.5 Message Arguments
3.3.6 Table Support Qualifier
3.3.6.1 Index
3.3.6.2 Argument lists
3.3.7 End Of Packet
3.4 Modem Commands
Page
3.4.1 IP Commands 3.4.1.1 Admin Commands
Page
Page
Page
Page
Page
Page
Page
3.4.2 Interface Commands
Page
3.4.3 QoS Commands
Page
Page
Page
3.4.4 Protocol Commands
Page
Page
3.4.6 Operations and Maintenance Commands
Page
Page
Page
3.4.7 Redundancy Commands
3.4.8 Routing Commands
Page
Page
3.4.9 Statistics Commands
3.4.9.1 Wan Stats
Page
3.4.9.2 IP Stats
Page
Page
3.4.9.3 Ethernet Stats
Page
3.4.9.4 QoS Stats
3.5 PARAM Files
This section gives more detail about the possible values of various parameters in PARAM file.
Page
Page
Page
Page
Page
Page
Errata A
Page
Errata B
Page
Errata C
Page
Errata D
Comments:
Change Specifics:
12.2 Demodulator
Page
Errata E
Subject: Changed Figure 7-5, TPC Curve for Rate 7/8
Comtech Turbo Product Codec Rate 7/8 QPSK/OQPSK, 8-PSK and 16-QAM
Figure 7-5. Comtech EF Data Turbo Product Codec Rate 7/8 QPSK/OQPSK, 8-PSK AND 16-QAM
Errata F
Comments:
Change Specifics:
Change to APU Target Eb/No Parameter
Page
Errata G
Page
Errata H
Subject: Revised Options Table
Page
Errata J
25 PIN D TYPE MALE
CDM-570LEIA530TOV.35DCECONVERSIONCABLE
34 PIN WINCHESTER FEMALE
FEMALE
25 PIN D MALE
LENGTH = TBD
Errata K
Page
Errata L
Subject: Revised BUC Reference
Page
CDM-570/570L
Installation and Operation Manual
Page
Table of Contents
Page
Page
Page
Page
Page
Page
Page
Page
Page
Figures
Tables
Preface
Customer Service
About this Manual
Conventions and References Metric Conversion
Cautions and Warnings
Recommended Standard Designations
Reporting Comments or Suggestions Concerning this Manual
Electrical Safety
Fuses
Environmental
Installation
~
Telecommunications Terminal Equipment Directive
EMC (Electromagnetic Compatibility)
Warranty Policy
Limitations of Warranty
Exclusive Remedies
Disclaimer
Chapter 1. INTRODUCTION
1.1 Introduction
1.1.1 EDMAC
1.1.2 AUPC
1.1.3 Software Flash Upgrading
1.1.4 Verification
1.1.5 Data Interfaces
1.2 Major Assemblies
1.3 FAST Options and Hardware Options
1.3.1 FAST Accessible Options
1.3.2 FAST System Theory
1.3.3 Implementation
1.3.4 Hardware Options
1.3.5 Supporting Hardware and Software
1.4 Compatibility
1.5 New in this release
Page
Page
Chapter 2. INSTALLATION
2.1 Unpacking
2.2 Mounting
2.2.1 Optional Rear-Mounting Installation Bracket
Page
2.3 Configuration
2.4 Select Internal IF Loop
2.5 Connect External Cables
Chapter 3. FUNCTIONAL DESCRIPTION
Page
Chapter 4. PHYSICAL DESCRIPTION
4.1 Introduction
4.2 Front Panel
4.3 Rear Panel
4.3.1 IEC Line Input Connector
4.3.2 Rx and Tx IF Connectors
4.3.3 Data Interface Connector
Page
Page
4.4 Dimensional Envelope
Chapter 5. CONNECTOR PINOUTS
5.1 Connector Overview
5.2 Data Interface Connector
THE MODEM IS ALWAYS ASSUMED TO BE DCE.
5.3 Balanced G.703 Interface Connector
5.4 Remote Control Interface C o nnector
5.5 BNC Connectors
5.6 Unit Alarms
5.7 1:1 Control Connector
5.8 Async-Serial Console (Optional IP Module Only)
5.9 Ethernet Interface Connectors (Traffic and M&C)
5.10 AC Power Connect or
5.11 Ground Connector
Chapter 6. FRONT PANEL OPERATION
6.1 INTRODUCTION
Page
Page
Page
6.2 OPENING SCREEN
6.3 MAIN SELECT MENU
6.4 CONFIG
CONFIG: Remote All Tx Rx Frame Intfc Ref Mask ODU
6.5 (CONFIG) REMCONT (Remote control)
6.5.1 (CONFIG, REMOTE) SERIAL
(CONFIG, REMOTE, SERIAL, INTERFACE)
(CONFIG, REM, SERIAL, INTFC, ADDR) RS485 BUS ADDRESS
(CONFIG, REM, SERIAL, BAUD RATE)
6.5.2 (CONFIG, REMOTE) ETHERNET
(CONFIG, REMOTE, ETHERNET) GATEWAY
(CONFIG, REMOTE, ETHERNET) ADDRESS
(CONFIG, REMOTE, ETHERNET) MAC
(CONFIG, REMOTE, ETHERNET) SNMP
(CONFIG, REMOTE, ETHERNET, SNMP) Communities
(CONFIG, REMOTE, ETHERNET, SNMP) Traps
6.6 (CONFIG) ALL
6.7 (CONFIG) TX (Transmit)
Tx:FEC Mod Code Data Frq On/Off Pwr Scram Clk Inv
6.7.1 (CONFIG, TX) FEC TYPE
Tx FEC: Viterbi Vit+RS TCM+RS TPC LDPC Uncoded
6.7.2 (CONFIG, TX) MODULATION
6.7.3 (CONFIG, TX) CODE RATE
Modulation: BPSK QPSK OQPSK 8-PSK 16-QAM 8-QAM
Tx Code Rate: 5/16 21/44 1/2 2/3 3/4 7/8 0.95 Unc
6.7.4 (CONFIG, TX) DATA RATE
Tx Dat Rate:5000.000kbps 3000.000ksym ( , ,ENT)
6.7.5 (CONFIG, TX) FREQUENCY
6.7.6 (CONFIG, TX) ON/OFF
6.7.7 (CONFIG, TX) POWER
(CONFIG, TX, PWR, MODE) MANUAL
Tx Output Power Level: -03.9 dBm ( , ENT)
Warning! AUPC needs Framed Mode (ENT or CLR)
Output Power Level Mode: Manual AUPC ( ,ENTER)
(CONFIG, TX, PWR, MODE) AUPC
(CONFIG, TX, PWR, MODE, AUPC) TARGET EbNo
(CONFIG, TX, PWR, MODE, AUPC) MAX RANGE
(CONFIG, TX, PWR, MODE, AUPC) ALARM
(CONFIG, TX, PWR, MODE, AUPC) DEMOD-UNLOCK
6.7.8 (CONFIG, TX) SCRAMBLING
6.7.9 (CONFIG, TX) CLOCKING
Tx Scrambling:Default-On IESS-315-On Off ( ,ENT)
Tx Clocking Mode: Int Ext Loop-Timed ( ,ENT)
6.7.10 (CONFIG, TX) INVERSION FUNCTIONS
(CONFIG, TX, INV) SPECTRUM
(CONFIG, TX, INV) DATA
6.8 (CONFIG) RX (Receive)
Rx:FEC Dem Code Data Frq Acq Descram Buf Inv EbNo
6.8.1 (CONFIG, RX) FEC TYPE
Rx FEC: Viterbi Vit+RS TCM+RS TPC LDPC Uncoded
6.8.2 (CONFIG , RX) DEMODULA TION
6.8.3 (CONFIG, RX) CODE RATE
Demodulation: BPSK QPSK OQPSK 8-PSK 8-QAM 16-QAM
Rx Code Rate: 5/16 21/44 1/2 2/3 3/4 7/8 0.95 Unc
6.8.4 (CONFIG, RX) DATA RATE
Rx Dat Rate:5000.000kbps 2500.000ksym ( , ,ENT)
6.8.5 (CONFIG, RX) FREQUENCY
6.8.6 (CONFIG, RX) ACQ
6.8.7 (CONFIG, RX) DESCRAMBLING
Descrambling: Default-On IESS-315-On Off ( ,ENT)
6.8.8 (CONFIG, RX) BUFFER
6.8.9 (CONFIG, RX) INVERSION FUNCTIONS
Timing Mode)( , ENTER)
(13.1ms) ( , ENTER)
Rx Inversion functions: Spectrum Data ( ,ENT)
6.8.10 (CONFIG, RX) Eb/No
6.9 (CONFIG) FRAME (Framing Mode)
6.9.1 (CONFIG, FRAME) UNFRAMED
6.9.2 (CONFIG, FRAME) EDMAC or EDMAC-2
(CONFIG, FRAME, FRAMED EDMAC+AUPC, MODE)
EDMAC Mode: Master Slave ( ,ENTER)
Framing mix: AUPC-Only AUPC+EDMAC ( ,ENTER)
Address of this Slave Unit: 0241 ( , ,ENT)
Distant-end Base Address 0240 ( , ,ENTER)
6.10 (CONFIG) INTERFACE
T1 Line Code (B8ZS): On Off(AMI) ( ,ENTER)
T1 Line Length: 000-133 feet ( ,ENTER)
E1 Line Code (HDB3): On Off ( ,ENTER)
6.11 (CONFIG) REFERENCE
6.12 (CONFIG) MASK
Reference Alarm: Active Masked ( ,ENT)
BUC Alarm: Active Masked ( ,ENT)
LNB Alarm: Active Masked ( ,ENT)
6.13 (CONFIG) ODU (CDM-570L ONLY)
6.13.1 (CONFIG, ODU) BUC
ODU (Outdoor Unit): BUC LNB ( ,ENTER)
BUC: M&C-FSK DC-Power 10MHz Alarm LO Mix ( )
(CONFIG, ODU, BUC) M&C-FSK
(CONFIG, ODU, BUC, M&C-FSK) FSK-Comms
(CONFIG, ODU, BUC, M&C-FSK) Address
BUC M&C(FSK): FSK-Comms Address Tx-On/Off ( )
BUC M&C FSK Comms: On Off ( ,ENTER)
(CONFIG, ODU, BUC, M&C-FSK) TX-ON/OFF
(CONFIG, ODU, BUC) DC-POWER
(CONFIG, ODU, BUC) 10MHz
(CONFIG, ODU, BUC) ALARM
(CONFIG, ODU, BUC) LO
BUC Current Alarm Upper Limit:1200mA ( , ,ENT)
BUC Current Alarm Lower Limit:1200mA ( , ,ENT)
BUC LO Frequency: 12000 MHz ( , ,ENTER)
(CONFIG, ODU, BUC) MIX
6.13.2 (CONFIG, ODU) LNB
(CONFIG, ODU, LNB) VOLTAGE
BUC Frequency Mix: High-Side Low-Side ( )
LNB: DC-Voltage 10MHz Alarm LO Mix ( , ENT)
(CONFIG, ODU, LNB) 10MHz
(CONFIG, ODU, LNB) ALARM
(CONFIG, ODU, LNB) LO
(CONFIG, ODU, LNB) MIX
LNB Frequency Mix: High-Side Low-Side ( )
LNB LO Frequency: 12000 MHz ( , ,ENTER)
6.14 MONIT (Monitor)
6.14.1 (MONIT) ALARMS
(MON, ALARMS) UNIT (Unit alarms)
(MON, ALARMS) RECEIVE (Receive Traffic Status)
(MON, ALARMS) TRANSMIT (Transmit Traffic Status)
(MON, ALARMS) ODU (Outdoor Unit alarms)
Tx Traffic: No Tx Clock from Terrestrial (ENT)
ODU Alarms: BUC Current Over Limit (ENT)
6.14.2 (MONIT) RX-PARAMS (Receive Parameters)
EbNo=05.7dB BER=3.4E-9 F=+11.7k Buf=50 RSL=-64
Demod: Not Locked RSL=-64
6.14.3 (MONIT) EVENT-LOG (STORED EVENTS)
(MON, EVENTS) VIEW
6.14.4 (MONIT) STATS (Link Statistics)
(MONIT, STATS) VIEW
Link Statistics: View Clear-All Config( ,ENT)
Sta198:02/11/02 10:37:32 16.0, 16.0, 9.0, 9.0( )
(MONIT, STATS) CLEAR
(MONIT, STATS) CONFIGURE
Stats Logging Interval: Disabled ( ,ENTER)
Stats Logging Interval: 30 minutes ( ,ENTER)
Clear all Stored Stats? No Yes ( , ENTER)
6.14.5 (MONIT) AUPC
6.14.6 (MONIT) ODU
BUC:DC=47.8V,3.25A SW=05 T=+38C PLL=Flt Pwr=02.1W
6.15 TEST
TEST: Norm IF> Dig> I/O> RF> Tx-CW Tx-1,0( ,ENT)
Page
6.16 INFO (Information)
6.16.1 (INFO) ALL
6.16.2 (INFO) TX (Transmit information)
INFO:All Tx Rx Buf Frame Intfc Rem Msk Ref ID 1:1
6.16.3 (INFO) RX (Receive information)
6.16.4 (INFO) BUFF (Buffer information)
Buffer: Enabled (Tx=Rx) Size:+/-04096 bits (ENT)
Rx:1140.000 5000.000 TUR 8P 0.95 D BUF +/-32k I
6.16.5 (INFO) FRAME (Framing and EDMAC information)
6.16.6 (INFO) INTFC (Interface information)
6.16.7 (INFO) REMCONT (Remote Control information)
6.16.8 (INFO) MASK (Alarm mask information)
6.16.9 (INFO) REF (Frequency Reference)
6.16.10 (INFO) ID (Circuit ID)
6.16.11 (INFO) 1:1 (1:1 Redundancy information)
6.17 SAVE/LOAD
6.17.1 (SAVE/LOAD) SAVE
6.17.2 (SAVE/LOAD) LOAD
6.18 UTILITY
6.18.1 (UTIL) BUFFER (Buffer re-center)
6.18.2 (UTIL) CLOCK (Set real-time clock)
6.18.3 (UTIL) REF (Reference)
(UTIL, REF) ADJUST
(UTIL, REF) WARM-UP DELAY
Internal 10 MHz Freq Ref Fine Adjust:+017( , )
Internal Freq Ref:Adjust Warm-up delay ( ,ENTER)
Comtech CDM-570L Modem Ref Warming-up: 045 secs
6.18.4 (UTIL) ID (Circuit ID)
6.18.5 (UTIL) 1:1 (Manual 1:1 switchover)
6.18.6 (UTIL) VFD (VFD Display brightness)
6.18.7 (UTIL) FIRMWARE
6.18.8 (UTIL) FAST (FAST code options)
View Options: 03 ( ) 150W BPSU Not Installed
FAST Demo Mode: Off On 604800 seconds remain
FAST Demo Mode: Off On Demo Period Expired
Page
Page
Chapter 7. FORWARD ERROR CORRECTION OPTIONS
7.1 Introduction
7.2 Viterbi
7.3 Reed-Solomon Outer Codec (Hard war e Option)
Page
7.4 Trellis Coding (requires 8-PSK/8-QAM FAST Option)
7.5 Turbo Product Codec (Hardware Option) 7.5.1 Introduction
7.5.2 TPC modes available in the CDM-570/570L
7.5.3 8-QAM Modulation
7.5.4 End-to-End Processing Delay
7.5.5 Comparison of all TPC Modes
7.6 Uncoded Operation (No FEC)
7.7 Rates above 2.5 Msymbols/sec
Viterbi Decoding
Vi ter b i with concatenated RS 220,200 Outer Code
8-PS K/ TCM Rate 2/ 3 Decoding, wi th 220, 200 RS O u ter Co d e
Comtech Turbo Product Codec Rate 3/4 QPSK/OQPSK, 8-PSK and 16-QAM
Comtech Turbo P roduct Codec Rate 7/8 QPSK/OQPSK, 8-PSK and 16-QAM
Comtech Turbo Product Codec Rate 21/44 QPSK/OQPSK Rate 0.95 QPSK/OQPSK and 8-PSK
Comtech Turbo P roduct Codec Rate 21/44 BP SK Rate 5/16 BPSK
Comtech Turbo Product Code c Rate 3/4 8-QAM Rate 0.95 8-QAM
Comtech Turbo Product Code c Rate 7/8 8-QAM
16-QAM Viterbi, Rate 3/4 and Rate 7/8 wi th 220, 200 RS Ou ter Cod e
Differential Encoding - No FEC, n o scrambling
Chapter 8. OFFSET QPSK OPERATION
Page
Chapter 9. CLOCKING MODES
9.1 Transmit Clocking
9.1.1 Internal Clock
9.1.2 Tx Terrestrial
9.1.3 Rx Loop-Timed, Rx=Tx
9.1.4 Rx Loop-Timed, Rx<>Tx (Asymmetric Loop Timing)
Page
Page
Page
Page
Chapter 10. EDMAC CHANNEL
10.1 Theory Of Operation
10.2 M&C Connection
10.3 Setup Summary
Page
Chapter 11. AUTOMATIC UPLINK POWER CONTROL
11.1 Introduction
11.2 Setting AUPC Parameters
11.2.1 Target Eb/No
11.2.2 Max Range
11.2.3 Alarm
11.2.4 Demod Unlock
11.3 Compensation Rate
11.4 Monitoring
Chapter 12. SUMMARY OF SPECIFICATIONS
12.1 Modulator
Page
12.2 Demodulator
Comtech EF Data CDM-570L Transmit Power Spectral Density, referred to symbol rate
IMPORTANT NOTE:
12.3 Automatic Uplink Power Control
12.4 Data and Miscellaneous Interfaces
12.5 Data Rate Ranges
FEC Type Modulation Code Rate Data Rate Range EDMAC limited?
12.6 Miscellaneous
12.7 Approvals
CE as follo w s:
FCC
Page
Chapter 13. SERIAL REMOTE CONTROL
13.1 Introduction
13.2 RS-485
13.3 RS-232
13.4 Basic Protocol
13.5 Packet Structure
13.5.1 Start Of Packet
13.5.2 Address
13.5.3 Instruction Code
13.5.4 Instruction Code Qualifier
Page
13.5.5 Message Arguments
13.5.6 End Of Packet
riority parameter can override any of the parameters of lower priority.
p
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Chapter 14. ETHERNET MANAGEMENT (Base Modem)
14.1 Introduction
14.2 Ethernet Management Int erface Protocols
14.3 We b Server (HTTP) Interface
14.3.1 We b Server Menu Tree
Table 14-1. Web Server Menu Tree
14.4 SNMP Interface
14.4.1 Management Information Base (MIB) Files
14.4.2 SNMP Community Strings
14.4.3 SNMP Traps
14.5 Telnet Interface
Page
Page
Page
Page
Chapter 15. IP MODULE ETHERNET INTERFACE OVERVIEW
15.1 Introduction
15.2 Major Assemblies
15.3 IP Module Standard Features
15.3.1 10/100BaseT Ethernet Interface
15.3.2 Powerful Network Manage m ent
15.3.3 Remote softwar e/firmware upgrade via FTP
Page
15.3.10 easyConnect Mode
15.3.11 easyConnect Operation
15.4 IP Module Optional Features
15.4.1 3xDES Encryption with Ability to Change Keys
15.4.2 IP Header Compression
15.4.3 Payload Compression
15.4.3.1 ADLC vs. LZS Compression Comparison
15.4.4 Quality of Service
15.4.4.1 Maximum Bandwidth/Priority QoS Mode
Page
Page
15.4.4.2 Minimum/Maximum Bandwidth QoS Mode
15.4.4.3 DiffServ QoS Mode
Page
15.4.5 CDM-570/570L IP Module Demo Mode
15.5 IP Module Specifications
Page
Chapter 16. TYPICAL IP MODULE OPERATIONAL SETUPS
16.1 Overview
16.2 Modem Compatibility
16.3 IP Module Working Modes
16.3.1 easyConnect Working Mode
16.3.2 Router Working Mode Point-to-Point
16.3.3 Router Working Mode Point-to-MultiPoint
Page
Page
Chapter 17. IP MODULE - CLI AND TELNET OPERATION
17.1 Overview
Page
17.2 Main Menu Page
17.2.1 Administration Page
Page
17.2.1.1 Name/Password Confi gurati on Pa ge
17.2.1.2 Access Lists Page
The Access Lists page contains the following options/fields:
17.2.1.3 Feature Configurati on Pa ge
Page
17.2.1.4 3xDES Encrypt Configuration Page
enter
17.2.1.5 SMTP Configuration Page
17.2.1.6 SNMP Configuration Page
Page
17.2.1.7 Working Mode
17.2.1.8 easyConnect Multicast Option
17.2.1.9 Header/Payload Compression Refresh Rate
17.2.1.10 Payload Compression Refresh R ate
17.2.1.11 Telnet Timeout
17.2.2 Interface Configuration Page
17.2.2.1 Ethernet Interface Page
The Fast Ethernet Interface page is activated from the Interface Configuration page.
The Ethernet Interface page contains the following options/fields:
17.2.2.2 Satellite/HDLC Interface Page
17.2.2.3 Receiver HDLC Addresses Page
17.2.3 QoS (Quality of Service) Configuration Page
17.2.3.1 QoS Configuration Page Max/Priority Mode
Page
Page
Page
17.2.3.2 16.2.4.1 QoS Configuration Page Min/Max Mode
17.2.3.3 16.2.4.2 QoS Configuration Page DiffServ Mode
17.2.4 Route Table Configuration Page
The Route Table Configuration page contains the following options/fields:
M
IP M
Page
Page
17.2.5 Protocol Configuration Page
17.2.5.1 IGMP Information Page
IP M
Page
Page
17.2.5.2 ARP Table Utilities Page
Page
17.2.6 Vipersat Configuration Page
The Vipersat Configuration page is activated from the Main Menu page.
The Vipersat Configuration page contains the following options/fields:
17.2.7 Satellite Modem Page
17.2.8 Configuration Page
17.2.8.1 Transmit Modem Configurati on Page
Page
17.2.8.2 Receive Modem Configuration Page
Page
17.2.8.3 Framing Mode Configuration
17.2.8.4 Data Interface Configuration
17.2.8.5 Reference Configuration
Page
17.2.8.6 Alarm Mask Configuration
17.2.8.7 Block Up Converter (BUC) Configuration
17.2.8.8 Low Noise Block Converter (LNB) Configuration
17.2.9 Operations and Mainte na nc e Page
The Operations and Maintenance page is activated from the Main Menu page.
The Operations and Maintenance page contains the following options/fields:
M
17.2.9.1 Unit Information Page
17.2.9.2 Statistics Page
Page
Page
Page
Page
17.2.9.2.2 QoS Statistics Page
17.2.9.2.3 Ethernet Statistics Page
Page
17.2.9.2.4 WAN Statistics
Page
17.2.9.2.5 Compression Statistics
Page
17.2.9.3 Event Log Page
Page
17.2.9.4 Database Operations Page
17.2.9.5 Diagnostics Page
17.2.10 Telnet - Logout Option
Page
Page
HTTP Login Access Levels are defined as follows:
18.1.1 We b Server Menu Tree
Table 18-1. IP Module Web Server Menu Tree
18.2 Home Pages 18.2.1 Home Page
18.2.2 Contact Information
18.2.3 Support
IP Module . The user can also select to automatically attach the IP Module
18.2.4 Logoff
Page
Chapter 19. SNMP INTERFACE
19.1 SNMP Interface
19.2 CDM-570/570L Management Information Base (MIB) Files
Page
19.3 SNMP Community Strings
19.4 SNMP Traps
19.5 MIB-II
19.6 CDM-570/570L Private MIB
Page
Page
Page
Page
PC 9 PIN SERIAL PORT TO CDM-570L RS232 REMOTE CONTROL PORT
Page
Page
CDM-570/570L Satellite Modem with Optional IP Module Revision 4 Appendix B MN/CDM570L.IOM
B3
Page
Appendix C. FAST ACTIVATION PROCEDURE
C.1 Introduction
C.2 Activation Procedure C.2.1 Serial Number
C.2.2 View currently installed feat ures
C.2.3 Enter Access Codes
FAST Configuration: Edit Code Demo Mode
Edit 20 digit FAST Code: 00000000000000000000 ENT
Configured Successfully (ENTER or CLEAR)
C.2.4 Enable / Disable Demo Mode
Page
Appendix D. QUICK-START GUIDE
D.1 Introduction
D.1.1 Equipment List
Following equipment is required:
D.1.2 Equipment Setup
D.1.3 Transmit and Receive IF Configuration
D.1.4 Serial console port Command Line Interface (CLI) Configuration
Page
D.1.6 Restoring Factory Default Configuration
D.2 easyConnect Point-to-Point System Configuration
D.2.1 PC Configuration
D.2.2 CDM-IP Configuration
D.2.3 Setting IP Address(es)
D.3 Router Mode Point-to-Point System Configuration
D.3.1 PC Configuration
D.3.2 Setting CDM-IP Modems to Router Mode Operation
Perform the following steps on CDM-IP 1
D.3.3 Setting IP Address(es)
D.3.4 Set IP Stack DES Select Key to ClearRoute Table
Perform the following steps on CDM-IP 1
Perform the following steps on CDM-IP 2
Page
D.4 Troubleshooting IP Module
D.4.1 easyConnect Mode Troubleshooting
easyConnect Mode Troubleshooting
D.4.2 Router Mode Troubleshooting
phymon_callback(): enet link change! link=1
phymon_callback(): enet link change! link=0
Appendix E. FLASH UPGRADING
E.1 Ethernet FTP Upload Procedure
Page
Page
E.2 Ethernet IP Module FTP Upload Procedure
Page
E.3 USB Procedure
Appendix F. ODU OPERATION
F.1 Introduction
F.2 ODU Remote Control Address Setup
F.3 MENU TREES F.3.1 MODEM MAIN MENU
F.3.2 ODU
F.3.3 CSAT Transceiver Menus F.3.3.1 (ODU,ENABLE) System Type
F.3.3.2 (ODU,ENABLE) 1:1
F.3.3.3 (ODU,ENABLE,1:1) RED-BOX (Redundancy Controller Box)
F.3.3.4 (ODU,ENABLE,1:1,RED BOX) ONLINE
F.3.3.5 (ODU,ENABLE,1:1,RED BOX) MODE
F.3.3.6 (ODU,ENABLE,1:1,RED BOX) SWITCHES
F.3.3.7 (ODU,ENABLE,1:1,RED BOX) VOLTAGES
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
F.3.4 KST2000A/B Menus F.3.4.1 (ODU,ENABLE) Selections
F.3.4.2 (ODU,ENABLE) CONFIG (Configuration)
F.3.4.3 (ODU,ENABLE,CONFIG) TRANSMITTER
F.3.4.4 (ODU,ENABLE,CONFIG,TRANSMITTER) FREQUENCY
F.3.4.5 (ODU,ENABLE, CONFIG,TRANSMITTER) ATTEN (Attenuation)
F.3.4.6 (ODU,ENABLE,CONFIG,TRANSMITTER) OUTPUT
F.3.4.7 (ODU,ENABLE,CONFIG,TRANSMITTER) HPA
F.3.4.8 (ODU, ENABLE,CONFIG,TRANSMITTER) STATE
F.3.4.9 (ODU,ENABLE,CONFIG, TRANSMITTER) FAULT-LOGIC
F.3.4.10 (ODU,ENABLE, CONFIG) RECEIVER
F.3.4.11 (ODU,ENABLE, CONFIG,RECEIVER) FREQUENCY
F.3.4.12 (ODU,ENABLE, CONFIG,RECEIVER) ATTEN (Attenuation)
F.3.4.13 (ODU,ENABLE, CONFIG,RECEIVER) LNA / LNB
F.3.4.14 (ODU,ENABLE, CONFIG,RECEIVER,LNA) STATE
F.3.4.15 (ODU,ENABLE, CONFIG,RECEIVER,LNA) FAULT-LOGIC
F.3.4.16 (ODU,ENABLE, CONFIG,RECEIVER,LNA) CAL (Calibrate)
F.3.4.17 (ODU,ENABLE, CONFIG, RECEIVER, LNB) BAND
F.3.4.18 (ODU,ENABLE, CONFIG) MISCELLANEOUS
F.3.4.19 (ODU,ENABLE,CONFIG,MISCELLANEOUS) AGC (Auto Gain Control)
F.3.4.20 (ODU,ENABLE,CONFIG,MISCELLANEOUS) REF-ADJUST
F.3.4.21 (ODU,ENABLE) INFO (Information)
F.3.4.22 (ODU,ENABLE,INFO) TRANSMITTER
F.3.4.23 (ODU,ENABLE, INFO) RECEIVER
Page
F.3.5 (ODU,ENABLE) STATUS
Appendix G. GPS MODE
G.1 Hardware Setup:
G.2 Remote Commands:
METRIC CONVERSIONS
Units of Length
Temperature Conversions
Units of Weight
2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161