CDM-570/570L Satellite Modem with Optional IP Module Revision 4
Serial Remote Control MN/CDM570L.IOM
13–17
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Force 1:1
Switch
FSW= None Command only.
Forces the unit to toggle the Unit Fail relay to the ‘fail’ state for
approx 500ms. If the unit is a 1:1 pair, and it is currently the ‘On
Line’ unit, this will force a switchover, so the unit will then be in
‘Standby’ mode. The command is always executed by the unit,
regardless of whether it is stand-alone, in a 1:1 pair, or part of a
1:N system. This command takes no arguments.
FSW=
(message
ok)
N/A N/A
Circuit ID
String
CID= 24 bytes Command or Query.
Sets or queries the user-defined Circuit ID string, which is a fixed
length of 24 characters.
Valid characters include:
Space ( ) * + – , . / 0 9 and A thru Z
CID=
CID?
CID*
CID#
CID? CID=xxxxxxxxxxxxxxx
xxxxxxxxx
(see description of
arguments)