Quatech INTERBUS S manuals
Computer Equipment > Network Card
When we buy new device such as Quatech INTERBUS S we often through away most of the documentation but the warranty.
Very often issues with Quatech INTERBUS S begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Network Card Quatech INTERBUS S is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Network Card on our side using links below.
Quatech INTERBUS S Manual
160 pages 4.25 Mb
3 TABLE OF CONTENTS6 Table of contents chapter 27 1 The WAGO I/O System10 2 Buscoupler - INTERBUS S 2.1 Buscoupler - Hardware11 2.2 Supply Voltage - Electronics12 2.3 Supply Voltage - Field Side14 2.4 Bus connection and station (node) address16 3 The Enclosure and Specifications19 4 INTERBUS S4.1 Master Cards (Scanners, Host Controllers) 20 4.2 Configuration software21 5 Configuration of the fieldbus node in the master 5.1 Identification Code22 5.2 ID Code for WAGO I/O System23 5.3 IBS CMD configuration software5.3.1 CMD Software Package 29 5.4 Example of an applicationIll. 19: Example of an application The Interbus S station is composed as follows: Table 5: Assignment of the process image 31 6 Buscoupler startup and troubleshooting33 7 General conditions36 Digital Inputs (24 V AC/DC, 120 V AC, 230 V AC, 48 V DC) PN: 750-400...41543 Counter with enable input 750-404/000-001Frequency Counter Module, 750-404/000-003 46 + + --48 Functional description49 Structure of CONTROL and STATUS byte50 Structure of Input and Output dataTDmax= 2 * 52 Digital Outputs (Standard) PN 750-501...504, 516, 51954 Digital Outputs (Standard with diagnostics) PN 750-50656 Digital Outputs (Solid State Relay) PN 750-50958 Pulsewidth Module PN 750-51162 Digital Outputs (Relay) PN 750-512...514, 51774 Input for PT 100 PN 750-461, 750-461/000-002, 750-461/000-003, 750-48177 The numerical format for 750-461/000-00279 Input for Thermocouple Modules PN 750-462, 750-469, 750-462/000-XXX81 Temperature Ranges of the connectable sensors:82 The numerical formats83 2 Channel Analog Input 0-20 mA / 4- 20 mAPN 750-465, 750-466, 750-486, 750-465/000-001 88 2 / 4 Channel Analog Inputs 0-10 VPN 750-467, 468, 487, 488 92 2 Channel Analog Input 0-20mA / 4-20mAPN 750-472, 750-472/000-200, 750-474, 750-474/000-200 97 2-Channel Analog Input 10 V, 16 Bit, single ended 750-476 0 -10 V, 16 Bit, single ended 750-478 Function clamp and variants 101 Numerical format with status information102 Status byte103 2 Channel Analog Outputs 0-10 V PN 750-550, 750-580106 2 -Channel Analog Outputs 0-20 mA / 4-20 mA PN 750-552, 554, 584109 2 Channel Analog Outputs +/- 10 V PN 750-556114 Supply modules PN750-601, 602, 609, 610, 611, 612, 613, 615116 Binary spacer module PN 750-622118 SSI Encoder Interface PN 750-630, 750-630/000-001, 750-630/000-006120 Terminal Configuration:122 Quadrature Encoder Interface PN 750-631, 750-631/000-001124 Operational Characteristics:133 Structure of input and output data:138 Data exchange module PN 750-654141 Structure of input and output data: 149 Ex-1 Application in Explosive EnvironmentsEx-1.1 Foreword Ex-1.2 Protective measures Ex-1.3 Classific ation meeting CENELEC and IEC 153 i154 Ex-1.4 Classifications meeting the NEC 500Ex-1.4.1 Divisions Ex-1.4.2 Explosion protection groups 155 Ex-1.4.3 Temperature classesElectrical components for explosive areas are differentiated by temperature classes:8 Application in Explosive Environments Identification WAGO-I/O-SYSTEM 750 Modular I/O-System 156 Ex-1.5 Identification(750-400, 2 channel digital input module 24 V DC) Ex-1.5.1 For EuropeAccording to CENELEC and IECFig. 1-1: Application in Explosive Environments 9 Identification WAGO-I/O-SYSTEM 750 Modular I/O-System 157 Ex-1.5.2 For America(750-400, 2 channel digital input module 24 V DC) According to NEC 500PATENTSPENDING 24246 4100--02----03 CL I DIV 2 Grp.ABCD optemp code T4AExplosion group (gas group) Explosion protection group (condition of use category) Area of application (zone) Temperatureclass 158 Ex-1.6 Installation regulations
Also you can find more Quatech manuals or manuals for other Computer Equipment.