2.4Bus connection and station (node) address
Ill. 5: Bus connection
Fieldbus connection:
The Interbus interface is normally provided by D SUB connection according to US Standard EIA RS485 for data transmission by wires.
Outgoing
/DO
DO
/DI
DI
COM
PIN
6
1
7
2
3
5
9
cable
green
yellow
pink
gray
brown
commoning wire
commoning wire
PIN
6
1
7
2
3
Incoming
D-SUB (IN)
/DO
DO
/DI
DI
COM
Table 1: Wire connection Interbus S
The connection point of the D SUB connector is lowered in such a way that after a connector is installed placement in an 80mm high switchbox is possible.
INTERBUS S / Buscoupler | 7 |
:$*2Ç,2Ç6<67(0