Sanyo E11A102A manuals
Computer Equipment > Power Supply
When we buy new device such as Sanyo E11A102A we often through away most of the documentation but the warranty.
Very often issues with Sanyo E11A102A begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Power Supply Sanyo E11A102A is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Power Supply on our side using links below.
46 pages 2.81 Mb
3 Introduction4 1. Safety Precautions5 1. Installation Precautions2. Wiring Precautions 6 3. Operating Precautions7 4. Radio Frequency Interference5. Maintenance and Inspection Precautions 6. Relocation and Transportation Precautions 8 7. Battery Handling Precautions9 2. For Proper Operation10 3.Checking the Contents of the Package11 4. Overview12 5. External Dimensions and Part Names15 6. Installation16 6.4Preparation Before InstallationCAUTION ①Remove the front panel of the UPS cover Remove the insulation tape from the battery connector of the battery pack side ④ Connect the battery connector ⑤ Verify that Forced Bypass is set to “Inverter” ⑥Attach the battery cover ⑦ Attach the front panel 17 6.5 Attaching the StandProceed as follows to attach the supplied stands ①Prepare two supplied stands ②Place the UPS in the stand ③If required, secure the stand to the UPS with the screws 18 CAUTION19 7. Wiring21 8. Preparations Before Operation22 9. Operating Procedures26 10.User Settings27 10.2 Setup Menu OperationsSet all menu items with the following procedure This example shows how to set the “UPS operation mode” item to “Economy” ① With MAIN SW on the back panel set to “ON”, check that the green INV.ON/STAND BY indicator and the green OUTPUT indicators are not blinking ②Press and hold it for at least 3 seconds ③ Select the menu item to set by using the 5 LEDs surrounded by in the following figure Press and quickly release (within 3 seconds) so that a menu item selection LED Select the value to set by using the 4 LEDs surrounded by 28 11. Maintenance and Inspection29 11.4 Battery Maintenance(1) Battery backup time confirmation Depending on the results of the test, exchange the battery months Estimated battery replacement interval damage may result, so we recommend exchanging batteries early as a preventative and protective step Battery specifications leakage, and heat could result Battery disposal 30 11.5 Battery TestProceed as follows to perform a manual battery test ①Press and hold it for 2 seconds The green BATT. TEST indicator starts blinking, and the battery test starts Check the green BATT. TEST indicator for the results of the test After the battery blinking, press The green BATT. TEST indicator goes off and returns to its normal indication ・Mechanical failure ・Switching of Forced Bypass switch ・Setting MAIN SW to “OFF” ・Output power overload ・Pressing for 1 second or longer ・When stopping battery-testby power management software on the computer 31 11.6 Battery Exchange③Disconnect the battery connector ④ Pull the battery pack out ⑤Insert the new battery pack so that the connector faces forward ⑥ Connect the battery connector 32 ⑦Attach the battery cover⑧ Attach the front panel Rest the remaining battery service life with item 33 11.7 Bypass Fuse ExchangeCAUTION ①Stop the inverter by pressing and holding it for 1 second, and then set ④ Set MAIN SW to “ON”, and then start the UPS by pressing and holding it for 1 second For details about UPS startup, see §9.1 “UPS Startup (Normal Operation)” 34 12. Troubleshooting36 13. Alarm Sounds37 14. Maintenance Bypass Power Supply (Option)38 15. Functional Description40 15.2 Protective Functions41 15.3 Protective Function Table(*1): Press on the front panel of the UPS to stop the buzzer. If a failure occurs, contact your supplier or Sanyo Denki representative as soon as possible Buzzer sound patterns: (1) Continuous tone (2) (3)**********...... Continuous beeps (4) When item ⑪ is set to “Bypass”: ○ Blinks When item ⑪ is set to “OFF”: - 42 15.4 Specifications(*2): When input voltage waveform distortion is under 1% 43 16. Warranty
Also you can find more Sanyo manuals or manuals for other Computer Equipment.