10.User Settings
10.1Setup Menu Item ListYou can configure the UPS by setting the menu items in the following list. Configure it according to your environment and requirements.
The controls and indicators on the control panel are used to set items in the Setup menu. For details, see §10.2 “Setup Menu Operations”.
Whenever you change a menu item setting, we recommend that you place a check mark in the “Current Setting” field of the Setup Menu Item List.
|
|
|
|
|
|
|
|
|
|
| ● LED blinks |
|
|
|
|
|
|
|
|
|
|
| ○ LED off |
No. | Menu Item | Item Selection | Setting | Item Setting | Default | Current |
| Description |
|
| Notes |
LEDs | LEDs | Setting | Setting |
|
|
| |||||
|
|
|
|
|
|
|
| ||||
| UPS operation mode |
| Auto | ● ○ ○ ○ | * |
| Switch the UPS operating mode | automatically. | |||
① | ● ○ ○ ○ ○ | Double Conversion | ○ ● ○ ○ |
|
| Set the UPS operating mode to Double Conversion mode. | |||||
|
|
| Economy | ● ● ○ ○ |
|
| Set the UPS operating mode to Economy mode | ||||
|
|
| 100V | ● ○ ○ ○ | Refer |
| 100V setting (The default setting of Model: | ||||
② | Output voltage | ○ ● ○ ○ ○ | 110V | ○ ● ○ ○ | to |
| 110V setting (The default setting of Model: | ||||
(RESTART) | 115V | ● ● ○ ○ | the |
| 115V setting (The default setting of Model: | ||||||
|
|
| |||||||||
|
|
| 120V | ○ ○ ● ○ | right |
| 120V setting (The default setting of Model: | ||||
| Frequency sync range |
| 1% | ● ○ ○ ○ |
|
| ±1% allowance |
| Set the range (%) over which the output | ||
③ | ● ● ○ ○ ○ | 3% | ○ ● ○ ○ | * |
| ±3% allowance |
| frequency is adjusted to variations in the | |||
| (RESTART) |
|
|
|
|
|
|
|
| input frequency in Economy Mode and | |
|
| 5% | ● ● ○ ○ |
|
| ±5% allowance |
| ||||
|
|
|
|
|
| Active Filter Mode. | |||||
| Battery startup |
| 50Hz | ● ○ ○ ○ |
|
| 50Hz setting |
| Set the inverter output frequency when | ||
④ | ○ ○ ● ○ ○ |
|
|
| UPS restarts from the batteries from | ||||||
frequency | 60Hz | ○ ● ○ ○ | * |
| 60Hz setting |
| |||||
|
|
|
| stopped status. | |||||||
|
|
| Do not use this setting. | ● ○ ○ ○ |
|
| - |
|
|
|
|
|
|
| Workstation | ○ ● ○ ○ | * |
| Setting for communications by the power management software over serial | ||||
⑤ | PC Interface mode | ● ○ ● ○ ○ |
| or LAN connection. |
|
|
| ||||
|
|
|
|
| |||||||
|
|
| Serial Login | ● ● ○ ○ |
|
| Shutdown by serial login. |
|
|
| |
|
|
| Do not use this setting. | ○ ○ ● ○ |
|
| - |
|
|
|
|
| Serial baud rate |
| 9600 | ● ○ ○ ○ | * |
| Set the baud rate to 9600 bps. | Set the communications baud rate when | |||
⑥ | ○ ● ● ○ ○ | 4800 | ○ ● ○ ○ |
|
| Set the baud rate to 4800 bps. | a workstation, PC, or optional LAN card | ||||
|
|
| 2400 | ● ● ○ ○ |
|
| Set the baud rate to 2400 bps. | is connected. | |||
|
|
| Auto | ● ○ ○ ○ | * |
| Auto restart |
| Specify when to restart the UPS after a | ||
|
|
| OFF | ○ ● ○ ○ |
|
| The UPS stays off. |
| |||
| Restart time |
| 30% | ● ● ○ ○ |
|
| Same | behavior as Auto | when | power outage and shutdown of the UPS | |
⑦ | ● ● ● ○ ○ |
|
| battery charge reaches 30%. |
| due to final discharge of the batteries. | |||||
|
|
|
| ||||||||
(battery charge rate) | 50% | ○ ○ ● ○ |
|
| Same | behavior as Auto | when | When 30%, 50%, or 80% is selected, the | |||
|
|
|
|
| battery charge reaches 50%. |
| UPS does not restart until the batteries | ||||
|
|
|
|
|
|
| |||||
|
|
| 80% | ● ○ ● ○ |
|
| Same | behavior as Auto | when | are charged to the specified level. | |
|
|
|
|
| battery charge reaches 80%. |
|
|
| |||
|
|
|
|
|
|
|
|
|
| ||
|
|
| All patterns | ● ○ ○ ○ | * |
| All sounds |
|
|
| |
⑧ | Buzzer sound | ○ ○ ○ ● ○ | Pattern 1 | ○ ● ○ ○ |
|
| Do not emit sounds on power outage, battery test, battery test abnormal and overload. | ||||
Pattern 2 | ● ● ○ ○ |
|
| Emit alarm and key click sounds. |
|
| |||||
|
|
|
|
|
|
| |||||
|
|
| OFF | ○ ○ ● ○ |
|
| Emit key click sounds only. |
|
|
| |
|
|
| 1 second | ● ○ ○ ○ | * |
| Turn inverter off when pressed for 1 second. | Set the response time for | |||
|
|
|
|
|
|
|
|
|
|
| switch press to stop inverter |
|
|
| 3 seconds | ○ ● ○ ○ |
|
| Turn inverter off when pressed for 3 seconds. | ||||
⑨ | switch | ● ○ ○ ● ○ |
|
| power supply. | ||||||
|
|
|
| Turn inverter off on special operation. Select this setting to keep the | |||||||
| response time |
| Special operation |
|
|
| |||||
|
| ● ● ○ ○ |
|
| inverter from being turned off by an accidental operation. See §9.4 "UPS | ||||||
|
|
|
|
| |||||||
|
|
|
|
|
|
| Shutdown (Daily)" for operation details. |
| |||
| Overload recovery |
| Auto return | ● ○ ○ ○ | * |
| Auto recovery with time |
| Set the conditions for automatic switch | ||
⑩ | ○ ● ○ ● ○ |
|
| back to inverter power supply (auto | |||||||
|
|
|
|
|
|
| |||||
operation | Bypass | ○ ● ○ ○ |
|
| Fixed as bypass on overload |
| return) after switching to bypass power | ||||
|
|
|
|
| |||||||
|
|
|
|
|
| supply because of overload. | |||||
|
|
|
|
|
|
|
|
|
| ||
| Inverter stop |
| OFF | ● ○ ○ ○ | * |
| The UPS stays off. |
| Specify the UPS operation during | ||
⑪ | ● ● ○ ● ○ |
|
|
| |||||||
Operation (RESTART) | Bypass | ○ ● ○ ○ |
|
| Switch to bypass operation when | inverter power supply stops. | |||||
|
|
|
|
|
|
| inverter stops. |
|
|
| |
|
|
| Battery voltage level | ● ○ ○ ○ | * |
| When low battery voltage level is |
|
| ||
| Low battery voltage |
|
| detected. |
| Specify the timing for triggering the low | |||||
⑫ | ○ ○ ● ● ○ | 2 minutes | ○ ● ○ ○ |
|
| When remaining battery capacity | |||||
|
| ||||||||||
signal timing |
|
| is 2 minutes. |
| battery voltage signal. | ||||||
|
|
| 3 minutes | ● ● ○ ○ |
|
| When remaining battery capacity |
|
| ||
|
|
|
|
|
|
| |||||
|
|
|
|
| is 3 minutes. |
|
|
| |||
|
|
| 5 minutes | ● ○ ○ ○ | * |
| 5 minutes backup |
| Set the UPS backup time on power outage. | ||
| Battery backup time |
| 15 minutes | ○ ● ○ ○ |
|
| 15 minutes backup |
| An external battery must be connected for | ||
⑬ | ● ○ ● ● ○ | 30 minutes | ● ● ○ ○ |
|
| 30 minutes backup |
| settings of 15 minutes or higher. | |||
|
|
| 60 minutes | ○ ○ ● ○ |
|
| 60 minutes backup |
| (This item can’t take effect unless resetting | ||
|
|
|
|
|
|
|
|
|
| remaining battery life.) | |
|
|
| 180 minutes | ● ○ ● ○ |
|
| 180 minutes backup |
| |||
|
|
|
|
|
|
|
| ||||
|
|
| 5 years | ● ○ ○ ○ | * |
| 5 years lifetime type |
| Set the battery type. Set this when you | ||
⑭ | Battery type | ○ ● ● ● ○ | 10 years | ○ ● ○ ○ |
|
| 10 years lifetime type |
| exchange the battery or connect an external | ||
|
|
| battery. (This item can’t take effect unless | ||||||||
|
|
| 3 years | ● ● ○ ○ |
|
| 3 years lifetime type |
| resetting remaining battery life.) | ||
|
|
| 180 days | ● ○ ○ ○ | * |
| Check batteries every 180 days. | Set the interval (number of days) for the | |||
⑮ | Battery check schedule | ● ● ● ● ○ | 90 days | ○ ● ○ ○ |
|
| Check batteries every 90 days. | automatic battery check. The check is | |||
30 days | ● ● ○ ○ |
|
| Check batteries every 30 days. | carried out automatically when the | ||||||
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
| specified number of days has elapsed. | |
|
|
| None | ○ ○ ● ○ |
|
| No battery check. |
| |||
|
|
|
|
|
|
|
| ||||
| Reset remaining |
| Do not reset | ● ○ ○ ○ | * |
| Do not reset. |
|
|
| |
⑯ | ○ ○ ○ ○ ● |
|
|
|
| Reset the battery information | (remaining life, accumulated battery | ||||
| battery life |
| Reset | ○ ● ○ ○ |
|
| operating time, number of power outages, LED remaining life display), | ||||
|
|
|
|
|
|
| when you exchange the battery. |
|
|
Note
Changes to some menu items do not take effect until you restart the UPS. These items are indicated by (RESTART) in the "Menu Item" column. If a restart is required, be sure to power off the load devices before resetting. See §9.5 “UPS Shutdown (If Not to Be Used for More Than a Week)” for information about how to shut down the UPS, and §9.1 “UPS Startup (Normal Operation)” for information about how to start the UPS.