Introduction
1. Safety Precautions
1. Installation Precautions
2. Wiring Precautions
3. Operating Precautions
4. Radio Frequency Interference
5. Maintenance and Inspection Precautions
6. Relocation and Transportation Precautions
7. Battery Handling Precautions
2. For Proper Operation
3.Checking the Contents of the Package
4. Overview
5. External Dimensions and Part Names
5.2 Control Panel and Indicators
5.3 External Interfaces
6. Installation
6.4Preparation Before Installation
CAUTION
①Remove the front panel of the UPS
cover
Remove the insulation tape from the battery connector of the battery pack side
6.5 Attaching the Stand
Proceed as follows to attach the supplied stands
①Prepare two supplied stands
②Place the UPS in the stand
③If required, secure the stand to the UPS with the screws
CAUTION
7. Wiring
③Connect the input power plugs of the load devices to the output terminals
7.2 External Interface Connections
Connect a computer or option card as required
For details, see §5.3 “External Interfaces” and §10 “User Settings”
7.2.1 Connections to the PC Interface (PC I/F)
8. Preparations Before Operation
9. Operating Procedures
① Set MAIN SW on the back panel of the UPS to “ON”
②Press and hold for one second
① Check that MAIN SW on the back panel is set to “OFF”
②Press and hold it until the buzzer sounds. Release it when the buzzer sounds
①Set the breaker on your utility power breaker panel to “Off”
② Set the breaker on your utility power breaker panel to “On”
①Press and / hold for 1 second
①Press and hold for 1 second
② Set MAIN SW to the “OFF” position
10.User Settings
10.2 Setup Menu Operations
Set all menu items with the following procedure
This example shows how to set the “UPS operation mode” item to “Economy”
① With MAIN SW on the back panel set to “ON”, check that the green INV.ON/STAND
BY indicator and the green OUTPUT indicators are not blinking
11. Maintenance and Inspection
11.4 Battery Maintenance
(1) Battery backup time confirmation
Depending on the results of the test, exchange the battery
months
Estimated battery replacement interval
11.5 Battery Test
Proceed as follows to perform a manual battery test
①Press and hold it for 2 seconds
The green BATT. TEST indicator starts blinking, and the battery test starts
Check the green BATT. TEST indicator for the results of the test
11.6 Battery Exchange
③Disconnect the battery connector
④ Pull the battery pack out
⑤Insert the new battery pack so that the connector faces forward
⑥ Connect the battery connector
⑦Attach the battery cover
⑧ Attach the front panel
Rest the remaining battery service life with item
11.7 Bypass Fuse Exchange
CAUTION
①Stop the inverter by pressing and holding it for 1 second, and then set
④ Set MAIN SW to “ON”, and then start the UPS by pressing
and holding it for
12. Troubleshooting
Page
13. Alarm Sounds
14. Maintenance Bypass Power Supply (Option)
15. Functional Description
Page
15.2 Protective Functions
15.3 Protective Function Table
(*1): Press
on the front panel of the UPS to stop the buzzer. If a failure occurs, contact
your supplier or Sanyo Denki representative as soon as possible
Buzzer sound patterns:
15.4 Specifications
(*2): When input voltage waveform distortion is under 1%
16. Warranty
“Charge” on the main screen of “SANUPS SOFTWARE STANDALONE”
“Backup Time” on the main screen of “SANUPS SOFTWARE STANDALONE”
LED blinking for setting up menu