Contents
Main
Model: RAVE4013I-C
Owners Manual
NOTICE
DO NOT DISCARD
Listing Label Information/Location
A. Congratulations
Homeowner Reference Information
Safety Alert Key:
Table of Contents
User Guide
Installer Guide
Page
B. Limited Lifetime Warranty
Hearth & Home Technologies Inc. LIMITED LIFETIME WARRANTY
WARRANTY PERIOD:
B. Limited Lifetime Warranty (continued)
WARRANTY CONDITIONS:
This warranty is void if:
LIMITATIONS OF LIABILITY:
WARRANTY EXCLUSIONS:
1
C. BTU Speci cations
A. Appliance Certi cation
E. Non-Combustible Materials Speci cation
F. Combustible Materials Speci cation
1
B. Tempered Glass Speci cations
H. Requirements for the Commonwealth of Massachusetts
2
B. Your Fireplace
A. Gas Fireplace Safety
User Guide
C. Clear Space
E. Fixed Glass Assembly
D. Decorative Doors and Fronts
F. Remote Controls, Wall Controls and Wall Switches
G. Before Lighting Fireplace
CAUTION:
NOT FOR USE WITH SOLID FUEL
WARNING:
DO NOT CONNECT LINE VOLT- AGE (110/120 VAC OR 220/240 VAC) T O THE CONTROL VALVE.
I. After Fireplace is Lit
J. Frequently Asked Questions
3
Glass Cleaning
3
A. Maintenance Tasks-Homeowner
Doors, Surrounds, Fronts
Remote Control
Venting
B. Maintenance Tasks-Quali ed Service Technician
Gasket Seal and Glass Assembly Inspection
Firebox
Control Compartment and Firebox Top
Burner Ignition and Operation
4
15Heatilator RAVE4013I-C 2293-900 Rev. C 8/12
A. Typical Appliance System
Figure 4.1 Typical System
Installer Guide
B. Design and Installation Considerations
D. Inspect Appliance and Components
C. Tools and Supplies Needed
5
A. Selecting Appliance Location
B. Constructing the Appliance Chase
C. Clearances
D. Mantel and Wall Projections
Non-combustible Mantels
Combustible Mantels
Combustible Mantel Legs Or Wall Projections
Non-combustible Mantel Legs Or Wall Projections
Page
6
A. Vent Termination Minimum Clearances
6
Gas, Wood or Fuel Oil Termination Cap B Gas Termination Cap **
A *
X
V
Covered Alcove Applications
7
A. Approved Pipe
E. Vent Diagrams
C. Use of Elbows
7
B. Vent Table Key
D. Measuring Standards
Effective Height/ Length
Venting with 1 elbow
H
V
H
INSTALLED HORIZONTALLY
V
Venting with 2 elbows
H
V
V
H 1 H
H
INSTALLED HORIZONTALLY
V1 = 44 ft. Max. (13.4 m)
No Elbows
H
V
Venting with 2 elbows
Page
Venting with 4 elbows
Coaxial to Colinear Venting
TOP VENT
8
A. Pipe Clearances to Combustibles
8
B. Wall Penetration Framing
C. Install the Ceiling Firestop
D. Install Attic Insulation Shield
9
A. Top Vent
9
B. Securing and Leveling the Appliance
10
10
A. Assemble Vent Sections
C. Secure The Vent Sections
B. Assemble Slip Sections
D. Disassemble Vent Sections
E. Install Decorative Ceiling Components
F. Install Metal Roof Flashing
G. Assemble and Install Storm Collar
H. Install Vertical Termination Cap
I. Install Decorative Wall Components
J. Heat Shield Requirements for Horizontal Termination
K. Install Horizontal Termination Cap
11
A. Fuel Conversion
B. Gas Pressure
11
C. Gas Connection
D. High Altitude Installations
12
A. Wiring Requirements
B. IntelliFire Ignition System Wiring
12
C. Optional Accessories Requirements
E. Junction Box Installation
D. Electrical Service and Repair
13
13
A. Framing and Finishing Instructions
FACTORY-INSTALLED NON-COMBUSTIBLE BOARD
Page
B. Mantel and Wall Projections
Combustible Mantels
Non-combustible Mantels
Combustible Mantel Legs Or Wall Projections
Non-combustible Mantel Legs Or Wall Projections
C. Facing Material
Page
D. Decorative Fronts
Inside and Overlap Fit See Section 13.C.
14
14
F. Install the Mesh
G. Air Shutter Setting
E. Fixed Glass Assembly
Removing Fixed Glass Assembly
Replacing Fixed Glass Assembly
15
A. IntelliFire Ignition System
Symptom Possible Cause Corrective Action
15
IntelliFire Ignition System - (continued)
Symptom Possible Cause Corrective Action
16
16
A. Appliance Dimension Diagram
8-3/4 in. 222 mm
6-1/2 in. 165 mm 6-5/8 in. 168 mm
B. Vent Components Diagrams
SLP-FLEX-PIPE
26 in. 660 mm
Effective Height/Length Pipe
SLP-45 - 45 Elbow SLP90- 90 Elbow
B. Vent Components Diagrams (continued)
SLP-HRC-SS SLP-HRC-ZC-SS HORIZONTAL TERMINATION CAP
SLP90 SL-2DVP DVP-FBHT DVP-FBHT
7 IN. 178 mm 15-1/2 IN. 394 mm
12 IN. 305 mm
COAXIAL to COLINEAR VENTING
B. Vent Components Diagrams (continued) PVI-SLP
B. Vent Components Diagrams
Service Parts
C. Service Parts List
Service Parts
#12 Valve Assembly
Additional service part numbers appear on following page.
ITEM DESCRIPTION COMMENTS PART NUMBER
Service Parts RAVE4013i-C
NOTICE