Heatiator Rave4013i-c owner manual B. Mantel and Wall Projections

Models: Rave4013i-c

1 70
Download 70 pages 45.48 Kb
Page 53
Image 53
B. Mantel and Wall Projections

B. Mantel and Wall Projections

WARNING! Risk of Fire! Comply with all minimum clear- ances to combustibles as specified. Framing closer than the minimums listed must be constructed entirely of noncom- bustible materials (i.e., steel studs, concrete board, etc.) Failure to comply could cause fire.

Note: For non-combustible fireplace finish material (marble, stone, etc) specifications refer to Section 13.C.

Combustible Mantels

1/2 IN. Thick Wall

Sheathing 12 IN.

MAX.

MEASUREMENT

14 IN. FROM TOP OF MIN. FIREPLACE

OPENING

Figure 13.4 Clearances To Combustibles Mantels Or Other Combustibles Above Appliance

Non-combustible Mantels

1/2 IN.

 

Thick Wall

12 IN.

Sheathing

MAX.

 

 

14 IN.

 

MIN.

MEASUREMENT

 

FROM TOP OF

 

FIREPLACE

 

OPENING

1 IN.MIN.

 

4 IN.

 

MAX.

 

Figure 13.5 Clearances To Non-Combustible Mantels Or Other

Non-Combustibles Above Appliance

 

Combustible Mantel Legs Or Wall Projections Extending Past The Face Of The Fireplace

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 IN.

 

 

 

 

 

 

 

FIREPLACE

MINIMUM

 

 

3 FT. MAXIMUM

 

 

 

 

 

 

 

 

 

 

 

 

 

OPENING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6 IN.

 

 

 

 

 

 

 

 

 

MINIMUM

Figure 13.6 Combustible Mantel Leg or Wall Projections (Acceptable on both sides of opening)

Non-combustible Mantel Legs Or Wall Projections Extending Past The Face Of The Fireplace

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 IN.

 

 

 

 

 

 

 

 

 

 

UNLIMITED

FIREPLACE

MINIMUM

 

 

 

 

 

 

 

 

 

OPENING

 

 

 

7 IN.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 13.7 Non-Combustible Mantel Leg or Wall Projections (Acceptable on both sides of opening)