Heatiator Rave4013i-c owner manual I. After Fireplace is Lit, J. Frequently Asked Questions

Models: Rave4013i-c

1 70
Download 70 pages 45.48 Kb
Page 12
Image 12
I. After Fireplace is Lit

I. After Fireplace is Lit

Initial Break-in Procedure

The fireplace should be run three to four hours continuously on high.

Turn the fireplace off and allow it to completely cool.

Remove fixed glass assembly. See Section 14.E.

Clean fixed glass assembly. See Section 3.

Replace the fixed glass assembly and run continuously on high an additional 12 hours.

This cures the materials used to manufacture the fire- place.

NOTICE! Open windows for air circulation during fire- place break-in.

Some people may be sensitive to smoke and odors.

Smoke detectors may activate.

TO CEILING

 

 

 

126°F

 

 

128°F

FIREPLACE

129°F

 

OPENING

 

 

 

 

133°F

59 in.

 

 

 

136°F

53 in.

 

 

 

47 in.

139°F

 

 

41 in.

 

136°F

35 in.

 

 

29 in.

 

23 in.

 

 

MEASUREMENTS FROM

TOP EDGE OF THE OPENING

APPLIANCE FRONT

 

 

Figure 2.3. Wall Surface Temperatures Above Appliance

J. Frequently Asked Questions

 

 

ISSUE

SOLUTIONS

 

 

Condensation on the glass

This is a result of gas combustion and temperature variations. As the fireplace warms, this con-

densation will disappear.

 

 

 

Blue flames

This is a result of normal operation and the flames will begin to yellow as the fireplace is allowed

to burn for 20 to 40 minutes.

 

 

 

 

When first operated, this fireplace may release an odor for the first several hours. This is caused

Odor from fireplace

by the curing of materials from manufacturing. Odor may also be released from finishing materials

and adhesives used near the fireplace. These circumstances may require additional curing related

 

 

to the installation environment.

 

 

Film on the glass

This is a normal result of the curing process of the paint. Glass should be cleaned within 3 to 4

hours of initial burning. A non-abrasive cleaner such as gas appliance glass cleaner may be nec-

 

 

essary. See your dealer.

 

 

 

Noise is caused by metal expanding and contracting as it heats up and cools down, similar to the

Metallic noise

sound produced by a furnace or heating duct. This noise does not affect the operation or longevity

 

of the fireplace.

 

 

 

There may be some “cracking” noise coming from the fireplace during the first few heating and

 

cooling cycles. This noise is associated with settling rock and some minor cracking of larger

 

pieces of rock. This will lessen over time as the glass rock is conditioned to the heating and cool-

Optional Rock Media Kit

ing temperature changes.

 

 

It is expected that a few small pieces (approximately 10 pieces) of rock may fall through the base-

 

pan and come to rest on the fireplace bottom. This has no affect on fireplace performance.

 

 

Power Outages

This appliance can operated on battery power in the event of a power outage. To access the bat-

tery pack, the decorative front, mesh and glass assembly must be removed. Refer to Section 12

(battery backup)

for more details.

 

 

 

Wall above appliance feels hot to

No action necessary. This appliance ships with a non-combustible material attached. Specifica-

the touch.

tions of the attached non-combustible material are listed in Section 1.E.

 

 

12

Heatilator • RAVE4013I-C2293-900 Rev. C • 8/12

Page 12
Image 12
Heatiator Rave4013i-c owner manual I. After Fireplace is Lit, J. Frequently Asked Questions, Initial Break-inProcedure