Heatiator Rave4013i-c Top Vent - Vertical Termination No Elbows, V1 = 44 ft. Max. 13.4 m

Models: Rave4013i-c

1 70
Download 70 pages 45.48 Kb
Page 29
Image 29
Top Vent - Vertical Termination

Top Vent - Vertical Termination

No Elbows

V1 = 44 ft. Max. (13.4 m)

Note: If installing a vertical vent/termination off the top of the appliance, the optional exhaust restrictor may be needed.

Note: Use SLP Series

components only.

V1

Figure 7.8 Vertical Vent Maximum

Exhaust restrictors are recommended for these vertically terminated products which have excessive draft. Exhaust restrictors will compensate for high draft, and restore vi- sual flame height. If the vent configuration has a total ver- tical of 15-44 feet, an exhaust restrictor may be needed. The exhaust restrictor can be located in the appliance manual bag.

Exhaust restrictor Instructions

1.Locate the two pilot holes located in the inside firebox heat shield as shown in Figure 7.9.

2.Center the exhaust restrictor such that the through holes in the vent restrictor align with the pilot holes in the restrictor.

3.Use (2) ½” self-piercing screws to secure vent restric- tor to firebox heat shield. See Figure 7.10.

PILOT HOLES

Figure 7.9 Location of Pilot Holes

Figure 7.10 Exhaust Restrictor Installation

4.In some applications, such as those where the fire- place is elevated off the floor, the vent restrictor may be painted, but painting is not required.

Notice: Before painting, contact your dealer for information on the appropriate high temperature paint.

Heatilator • RAVE4013I-C2293-900 Rev. C • 8/12

29

Page 29
Image 29
Heatiator Rave4013i-c Top Vent - Vertical Termination No Elbows, V1 = 44 ft. Max. 13.4 m, Exhaust restrictor Instructions