Heatiator Rave4013i-c 15-1/2IN 394 mm, 7 IN 178 mm, 12IN 305mm, SLP90, SL-2DVP, Dvp-Fbht

Models: Rave4013i-c

1 70
Download 70 pages 45.48 Kb
Page 64
Image 64
SLP-HRC-SS

Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield is designed to be used on a wall 4 in. to 7-1/4 in. (102 mm to 184 mm) thick. If wall thickness is less than 4 in. (102 mm) the existing heat shields must be field trimmed. If wall thickness is greater than 7-1/4 in. (184 mm) a DVP-HSM-B will be required.

HORIZONTAL TERMINATION CAP 8 in.15-1/2 IN. (203 mm)

Heat

Shield

15-1/8 in.

(384 mm)

 

Max

12 in.

Effective

(305 mm)

Length

SLP-TRAP

Horizontal Termination Cap

Term Cap

Minimum

Maximum

Effective Length

Effective Length

 

Trap1

3-1/8 in.

4-3/4 in.

79 mm

121 mm

 

Trap2

5-1/4 in.

9-1/4 in.

133 mm

235 mm

 

8-1/8 in.

(206 mm)

15 in.

(381 mm)

13in.

(330 mm)

Effective Length 5-3/4 to 8-3/8 in. 146 to 213 mm

5-1/2 in.

8-3/8 in.

140 mm

213 mm

87° 7 IN.12IN.SLP90

DVP-FBHTManual background 10-1/2 in.

267 mm

10-7/8 in. 276 mm

CAUTION: THE SLP-HRC-SS AND SLP-HRC-ZC-SS TERMINATION CAPS ARE NOT APPROVED FOR USE WITH PROPANE (LP) FUEL. May lead to ele- vated glass temperature that may cause tempered glass breakage.

SLP-HRC-SS

SLP-HRC-ZC-SS

HORIZONTAL TERMINATION CAP

15-1/2 IN.

394 mm

7 IN.

178 mm Manual background

12IN.

305mm

 

SLP90

SL-2DVP

DVP-FBHT

DVP-FBHT

 

Figure 16.4 SLP Series Vent Components

 

 

64

 

Heatilator • RAVE4013I-C2293-900 Rev. C • 8/12

Page 64
Image 64
Heatiator Rave4013i-c 15-1/2IN 394 mm, 7 IN 178 mm, 12IN 305mm, SLP90, SL-2DVP, Dvp-Fbht, Slp-Hrc-Ss Slp-Hrc-Zc-Ss