Safety Alert Key:

DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury.

WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury.

CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.

NOTICE: Used to address practices not related to personal injury.

Table of Contents

A. Congratulations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 B. Limited Lifetime Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . 5

1 Listing and Code Approvals

A. Appliance Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 B. Tempered Glass Specifications . . . . . . . . . . . . . . . . . . . . . 7 C. BTU Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 D. High Altitude Installations . . . . . . . . . . . . . . . . . . . . . . . . . . 7 E. Non-Combustible Materials Specification. . . . . . . . . . . . . . 7 F. Combustible Materials Specification . . . . . . . . . . . . . . . . . 7 G. Electrical Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 H. Requirements for the Commonwealth of Massachusetts. . 8

User Guide

2 Operating Instructions

A. Gas Fireplace Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 B. Your Fireplace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 C. Clear Space . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 D. Decorative Doors and Fronts . . . . . . . . . . . . . . . . . . . . . . 10 E. Fixed Glass Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 F. Remote Controls, Wall Controls and Wall Switches. . . . . 10 G. Before Lighting Fireplace . . . . . . . . . . . . . . . . . . . . . . . . . 10 H. Lighting Instructions (IPI) . . . . . . . . . . . . . . . . . . . . . . . . . 11 I. After Fireplace is Lit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

J. Frequently Asked Questions . . . . . . . . . . . . . . . . . . . . . . 12

3 Maintenance and Service

A. Maintenance Tasks-Homeowner . . . . . . . . . . . . . . . . . . . 13 B. Maintenance Tasks-Qualified Service Technician . . . . . . 14

Installer Guide

6 Termination Locations

A. Vent Termination Minimum Clearances . . . . . . . . . . . . . . 22

7 Vent Information and Diagrams

A. Approved Pipe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

B. Vent Table Key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

C. Use of Elbows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

D. Measuring Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

E. Vent Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

8 Vent Clearances and Framing

A. Pipe Clearances to Combustibles . . . . . . . . . . . . . . . . . . 35 B. Wall Penetration Framing. . . . . . . . . . . . . . . . . . . . . . . . . 35 C. Install the Ceiling Firestop . . . . . . . . . . . . . . . . . . . . . . . . 36 D. Install Attic Insulation Shield. . . . . . . . . . . . . . . . . . . . . . . 37

9 Appliance Preparation

A. Top Vent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 B. Securing and Leveling the Appliance . . . . . . . . . . . . . . . . 39

10 Installing Vent Pipe (SLP Pipe)

A. Assemble Vent Sections. . . . . . . . . . . . . . . . . . . . . . . . . . 40 B. Assemble Slip Sections . . . . . . . . . . . . . . . . . . . . . . . . . . 41 C. Secure The Vent Sections . . . . . . . . . . . . . . . . . . . . . . . . 41 D. Disassemble Vent Sections . . . . . . . . . . . . . . . . . . . . . . . 42 E. Install Decorative Ceiling Components . . . . . . . . . . . . . . 42 F. Install Metal Roof Flashing. . . . . . . . . . . . . . . . . . . . . . . . 43 G. Assemble and Install Storm Collar . . . . . . . . . . . . . . . . . . 43 H. Install Vertical Termination Cap . . . . . . . . . . . . . . . . . . . . 44 I. Install Decorative Wall Components . . . . . . . . . . . . . . . . 44 J. Heat Shield Requirements for Horizontal Termination . . . 44 K. Install Horizontal Termination Cap . . . . . . . . . . . . . . . . . . 45

4 Getting Started

A. Typical Appliance System

15

11 Gas Information

 

A. Fuel Conversion

46

B. Design and Installation Considerations

16

C. Tools and Supplies Needed

16

B. Gas Pressure

46

D. Inspect Appliance and Components

16

C. Gas Connection

47

5 Framing and Clearances

 

D. High Altitude Installations

47

 

12 Electrical Information

 

A. Selecting Appliance Location

17

 

A. Wiring Requirements

48

B. Constructing the Appliance Chase

18

C. Clearances

19

B. IntelliFire Ignition System Wiring

48

D. Mantel and Wall Projections

20

C. Optional Accessories Requirements

48

 

 

D. Electrical Service and Repair

49

 

 

E. Junction Box Installation

49

Heatilator • RAVE4013I-C2293-900 Rev. C • 8/12

3

Page 3
Image 3
Heatiator Rave4013i-c owner manual Table of Contents, User Guide

Rave4013i-c specifications

The Heatiator Rave4013i-c stands out as an exceptional heating solution designed to provide efficient, reliable warmth while elevating the aesthetic appeal of any space. This advanced model offers a blend of innovative technology, high performance, and user-friendly features.

One of the most notable characteristics of the Rave4013i-c is its cutting-edge air distribution system. This ensures uniform heat distribution throughout the room, eliminating cold spots and providing consistent warmth. The unit's powerful heat output makes it suitable for various environments, including residential homes, offices, and commercial spaces.

The Rave4013i-c is equipped with energy-efficient technologies that reduce power consumption while maintaining optimal performance. With an impressive heating capacity, the unit is designed to heat larger spaces effectively without incurring steep energy costs. Users appreciate its eco-friendly design, which aligns with today's sustainability goals, helping to lower carbon footprints.

Another significant feature is the sophisticated digital control panel, which allows users to customize their heating experience. The intuitive interface provides easy access to various settings, including temperature adjustments, timer functions, and mode selection. This level of control ensures that users can achieve their desired comfort level with minimal hassle.

The Heatiator Rave4013i-c also boasts an aesthetically pleasing design, incorporating sleek lines and a modern finish that complements any decor. The charming appearance does not compromise its robustness; it is built from high-quality materials that promise durability and long-lasting performance.

Safety is a top priority for the Rave4013i-c. It includes essential safety features such as overheat protection and tip-over switches. These integrated safety measures provide peace of mind, especially in homes with pets and small children. Additionally, its low noise operation allows for peaceful enjoyment of the warmth generated, without disruptive sounds.

Versatility is another hallmark of the Rave4013i-c. It can be installed in various configurations, whether flush-mounted in a wall or standing independently, making it adaptable to different room layouts. This flexibility, combined with its heating efficiency and modern design, makes the Heatiator Rave4013i-c an ideal choice for anyone seeking a high-quality heating appliance that enhances both comfort and style.