Heatiator Rave4013i-c Top Vent - Vertical Termination, Venting with 3 elbows, RAVE4013I-C

Models: Rave4013i-c

1 70
Download 70 pages 45.48 Kb
Page 31
Image 31
Manual background

Top Vent - Vertical Termination

Venting with 3 elbows

RAVE4013I-C

 

V1 Minimum

H1 + H2 Maximum

V2

V1 + V2 Minimum

 

90° Elbow

1 ft.

305 mm

*

*

1 ft.

 

305 mm

2 ft.

610 mm

*

*

2 ft.

 

610 mm

4 ft.

1.2 m

*

*

3 ft.

 

914 mm

6 ft.

1.8 m

*

*

4 ft.

 

1.2 m

14 ft.

4.3 m

*

*

H MAX. =14 ft. (4.3 m)

V1 + V2 + H1 + H2 MAX. = 40 ft. (12.2 m)

* No specific restrictions on this value EXCEPT V1 + V2 + H1 + H2 cannot exceed 40 ft. (12.2 m)

V2

Note: Use SLP Series components only.

Note: There MUST be a 25% reduction in total H when using flex vent except when using the simple up and out installation (see Figure 7.3).

H1

H2

V1

INSTALLED

HORIZONTALLY

Figure 7.12

Heatilator • RAVE4013I-C2293-900 Rev. C • 8/12