3Com 3 manual Low Threshold Statistic High Threshold Recovery

Models: 3

1 103
Download 103 pages 16.51 Kb
Page 57
Image 57

RMON and the Switch 57

Table 6 Values for the default alarm(s)

 

 

Low Threshold

 

Statistic

High Threshold

Recovery

Period

Number of errors

Value: 8 errors per 10

over 10 seconds

seconds

 

Action: Smart

 

auto-sensing will reduce

 

port speed

Value: 8 errors per 10

10 secs

seconds

 

Action: None. (Speed can

 

only be increased upon

 

link loss, for example by

 

removing and replacing

 

the cable, or by triggering

 

the port to perform

 

another auto-negotiation

 

on that link.)

 

The Audit Log The Switch keeps an audit log of all management user sessions, providing a record of a variety of changes, including ones relating to RMON. The log can only be read by users at the security access level using an SNMP Network Management application.

Each entry in the log contains information in the following order:

Entry number

Timestamp

User ID

Item ID (including qualifier)

New value of item

The last 16 operations are stored in the audit log. The oldest records are overwritten first.

Email Notification of Your Switch allows you to receive email notification when certain RMON Events events occur. You can receive notification via email, SMS (Short Message

Service), or pager, of the event that has occurred.

This feature uses an SMTP (Simple Mail Transfer Protocol) email client to send the notification email. The Short Message Service (SMS) and pager messages are constrained on message size so they are sent to a different email address which creates the message to be displayed and then forwards it on to the SMS or pager gateway.

Page 57
Image 57
3Com 3 manual Low Threshold Statistic High Threshold Recovery