A complete list of S-Registers A-5

A complete list of S-Registers

.

Register Default Function

S0

0

Sets the number of rings on which to answer in Auto

 

 

Answer mode. S0=0 disables Auto Answer. S0=1 enables

 

 

Auto Answer and the Business Modem answers on the first

 

 

ring.

 

 

 

S1

0

Counts and stores the number of rings from an incoming

 

 

call.

 

 

 

S2

43

Stores the ASCII decimal code for the escape code

 

 

character. Default character is “+”. A value of 128-255

 

 

disables the escape code.

 

 

 

S3

13

Stores the ASCII decimal code for the Carriage Return

 

 

character. Valid range is 0-127.

 

 

 

S4

10

Stores the ASCII decimal code for the Line Feed character.

 

 

Valid range is 0-127.

 

 

 

S5

8

Stores the ASCII decimal code for the Backspace character.

 

 

A value of 128-255 disables the Backspace key's delete

 

 

function.

 

 

 

S6

0

Set the number of seconds the Business Modem waits for a

 

 

dial tone.

 

 

 

S7

60

Sets the number of seconds the Business Modem waits for

 

 

a carrier. May be set for much longer duration if, for

 

 

example, the Business Modem is originating an

 

 

international connection.

 

 

 

S8

2

Sets the duration, in seconds, for the pause (,) option in the

 

 

Dial command and the pause between command

 

 

reexecutions (> and A> commands).

 

 

 

S9

6

Sets the required duration, in tenths of a second, of the

 

 

remote device's carrier signal before recognition by the

 

 

Business Modem.

 

 

 

S10

14

Sets the duration, in tenths of a second, that the Business

 

 

Modem waits after loss of carrier before hanging up. This

 

 

guard time allows the Business Modem to distinguish

 

 

between a line hit, or other disturbance that momentarily

 

 

breaks the connection, from a true disconnect (hanging up)

 

 

by the remote device

 

 

 

S11

70

Sets the duration and spacing, in milliseconds, of dialed

 

 

tones.

 

 

 

S12

50

Sets the duration, in fiftieths of a second, of the guard time

 

 

for the escape code (+++) sequence.