I-4APPENDIX I: S-REGISTERS

Register

Default

Function

 

 

 

S16

0

Bit-mapped register. (See Chapter 1, Using the AT

 

 

Command Set, for instructions on setting bit-mapped

 

 

registers.) For testing, see Chapter 14, Testing.

 

 

Bit

Value

Result

 

 

2

4

Test pattern.

 

 

3

8

Remote digital loopback.

 

 

 

S18

0

Test timer for software-initiated loopback testing (&Tn);

 

 

disabled when S18 is set to 0. Used to set the duration of

 

 

testing, in seconds, before the Business Modem

 

 

automatically times out and terminates the test.

 

 

 

S19

0

Sets the duration, in minutes, for the Inactivity Timer. The

 

 

timer activates when there is no data activity on the phone

 

 

line, and at the timeout the Business Modem hangs up.

 

 

S19=0 disables the timer.

 

 

 

S21

10

Sets, in 10-millisecond units, the length of breaks sent from

 

 

the Business Modem to the computer or terminal. Applies

 

 

to ARQ mode only.

 

 

 

 

S22

17

Stores the ASCII code for the XON character.*

 

 

 

S23

19

Stores the ASCII code for the XOFF character.*

 

 

 

S24

150

Sets the duration, in 20-millisecond units, between pulsed

 

 

DSR signals when the Business Modem is set to &S2 or &S3.

 

 

The default is 3 seconds.

 

 

 

S25

5

Sets DTR recognition time in 10-millisecond units.

 

 

 

S27

0

Bit-mapped register. (See Chapter 1, Using the AT

 

 

Command Set, for instructions about setting bit-mapped

 

 

registers.)

 

 

Bit

Value

Result

0

1

Enable ITU-T V.21 modulation at 300

 

 

bps for overseas calls. In V.21 mode,

 

 

the Business Modem answers both

 

 

Bell 103 and V.21 calls, but only

 

 

originates V.21 calls.

1

2

Enable unencoded (non- trellis-coded)

 

 

modulation in V.32 mode; this option

 

 

is part of the ITU-T V.32

 

 

recommendation, but is rarely used.

2

4

Disable V.32 modulation; used for

 

 

testing HST modulation.