3Com 86-0621-000, C36460T Appn, Bridge Static Routes, DLSw, bcmnbrus -NA, UpgradeLink -NA

Models: 86-0621-000 C36460T

1 64
Download 64 pages 12.2 Kb
Page 46
Image 46
APPN

46

File Conversion This section describes file conversion considerations for APPN, bridge static routes, Considerations DLSw, the PROfile service, and X.25 SVCs.

APPN

APPN file conversion is supported in software version 8.2 and later. Upgrading from software versions prior to 8.2 requires manual configuration.

High Performance Routing (HPR) is a new feature for the NETBuilder bridge/router after software version 8.3. If you use the Upgrade Management Utilities to convert your APPN data file from version 8.3 (or later) to 11.4, be sure to turn on HPR if HPR is desired using:

SETDefault !<port> -APPN PortDef = <DLC type> HPR=yes

Bridge Static Routes

A static bridge route configured with the off option does not convert properly. You must manually reconfigure this route.

DLSw

Initial Bandwidth for Peer is a new parameter for software version 8.3 and later. The default for version 11.0 is 8000. If you use the Upgrade Management Utilities to convert your DLSw data files from version 8.3 (or later) to 11.4, be sure to set the value of the parameter to the desired value using:

SETDefault <tunnel id> -Dlsw PEER = <IP address> <PrioMode> <8000 other

value>

UNIX Platform Symbolic When installing Enterprise OS software version 11.4 from a UNIX platform, do not Links follow symbolic links to reach a particular file (image or tar file) when using the

“Browse” option. Double-clicking a directory name that is a symbolic link will not connect to the directory. To open a directory, type the directory name and press “Enter.”

Upgrading From Release If you are upgrading a bridge/router from software version 8.3 or earlier, you must

8.3or Earlier disable user verification by specifying the -NA flag on bcmnbrus or Upgrade Link. For example:

bcmnbrus -NA

or

UpgradeLink -NA

Otherwise, an error dialog box is returned with the message “Could not verify user.”

If you use tftp, the “Verify Upgrade Services” step does not need the user or password to be verified, so those entries as well as the FTP Client User Name and Password, should be ignored.

Upgrade Link and Netscape version 4.05 with AWT patch 1.1.5 has the Java support required by Netscape Browser Scroll Enterprise OS software version 11.4 Upgrade Link. Certain problems have been

Bars found with this Netscape patch release, such as sometimes the Netscape browser

Page 46
Image 46
3Com 86-0621-000, C36460T software manual Appn, Bridge Static Routes, DLSw, bcmnbrus -NA, UpgradeLink -NA