IBM Protocols and Services Notes 51

and route discovery are configured, bridge numbers must be unique for each bridge/router on the same ring, and LLC2 is enabled on token ring ports.

Token Ring Frame Copy Errors

For transparent bridge or source route transparent configurations, token ring end systems may generate a small number of MAC frame copy error reports when the NETBuilder II bridge/router token ring interface is initializing or when the bridge/router ages out a MAC address from its bridge table.

For the bridge/router to learn the MAC addresses of transparent end systems on the token ring, it copies a packet with an unknown source address and sets the address-recognized (A) and frame-copied (C) bits in the Frame Status (FS) field. A problem occurs when the FS (A) and (C) bits have been set and the destination of the frame is an end system on the local ring. The destination end system expects the (A) and (C) bits to be zeros. When it receives a frame with these values already set, it reports an error. The end system counts these errors and accumulates them until the MAC layer Soft Error Report Timer period is reached; the default is two seconds. A MAC Report Error packet is then sent to the Ring Error Monitor (REM) Network Management entity.

A source route only configuration eliminates frame copy errors. Frame copy errors do not occur in source route only environments when the NETBuilder bridge/routers are configured properly. This is because the NETBuilder bridge/router hardware filters source-routed packets based on the route information field, not the MAC address. If the bridge/router is configured for source route only, it never copies frames destined for a station on the local ring. Frame copy errors can be eliminated by running in source-route-only mode.

Table 12 shows the features supported on the NETBuilder II and NETBuilder

SuperStack II token ring bridge/routers.

Table 12 3Com Bridge/Routers and Supported Features

 

Source Route

 

Source Route

 

 

Transparent

 

Transparent

 

Platform

Bridging

Routing

Gateway

Source Routing

 

 

 

 

 

NETBuilder II

Yes

Yes

Yes

Yes

SuperStack II NETBuilder

No

Yes

No

Yes

Token Ring

 

 

 

 

 

 

 

 

 

Frame Copy Errors under LAN Net Manager

Whenever LAN Net Manager is enabled, the token ring driver is set to N-way bridging mode, which means the bridge/router copies all frames that match the bridge number specified on the receiving port. If two NETBuilder bridge/routers are connected to the same ring with the same bridge number, frame copy errors will occur. To prevent this problem, do not configure two NETBuilder bridge/routers with the same bridge number on the same ring.

LAN Network Manager If you have previously configured your LAN Network Manager to use the

with NETBuilder II NETBuilder II system as a virtual ring, and you want to use it as a physical ring, you Systems must set your virtual ring number back to None.

Page 51
Image 51
3Com C36460T, 86-0621-000 software manual Token Ring Frame Copy Errors, Frame Copy Errors under LAN Net Manager