3Com C36460T Number of TCP Connections, Front-End, Relay port is, HPR and ISR, Configurations

Models: 86-0621-000 C36460T

1 64
Download 64 pages 12.2 Kb
Page 49
Image 49

IBM Protocols and Services Notes 49

You must reboot the bridge/router before this change takes effect. Table 9 shows the maximum number of circuits possible with the different CONNectionUsage parameter settings. The practical limit may be lower and depends on the traffic load, CPU, and memory usage by other services.

Table 9 DLSw Circuit Maximums with CONNectionUsage Parameter Settings

 

Maximum Number of DLSw Circuits

System

Low

Medium

High

 

 

 

 

OfficeConnect and SuperStack II

190

390

790

NETBuilder bridge/routers

 

 

 

Boundary router peripheral node*

n/a

n/a

790

NETBuilder II bridge/router

 

 

 

DPE modules

390

790

7990

*The CONNectionUsage parameter is set to High by the Boundary Router Peripheral node software; it cannot be changes.

The IBM Boundary Router peripheral node uses two LLC2 circuits to support one LLC2 end system. Therefore, the maximum number of LLC2 end systems supported by an IBM Boundary Router peripheral node is 395.

Number of TCP Connections

3Com LLC2 tunneling uses one TCP connection for each LLC2 session. DLSw scales to large networks better than LLC2 tunneling because it multiplexes all LLC2 sessions over one TCP connection per tunnel. Each Telnet session also uses one TCP connection. Table 10 shows the maximum number of TCP connections possible with the different CONNectionUsage parameter settings. The practical limit may be lower and depends on the traffic load, CPU, and memory usage by other services.

Table 10 TCP Circuit Maximums with CONNectionUsage Parameter Settings

 

Maximum Number of TCP Circuits

System

Low

Medium

High

 

 

 

 

OfficeConnect and SuperStack II

32

256

512

NETBuilder bridge/routers

 

 

 

Boundary router peripheral node*

n/a

n/a

790

NETBuilder II bridge/router

 

 

 

DPE module

32

512

2048

*The CONNectionUsage parameter is set to High by the Boundary Router peripheral node software; it cannot be changed.

Front-End

The maximum number of FradMap entries that may be defined for each Frame

Processor/Frame Relay

Relay port is 50.

Access for LLC2 Traffic

 

HPR and ISR

High Performance Routing (HPR) is enabled by default. Therefore, if you are

Configurations

configuring APPN Intermediate Session Routing (ISR), you must disable HPR on

 

both the PortDef and the AdjLinkSta parameters by setting HPR = No.

IBM Boundary Routing

In an IBM Boundary Routing topology that uses disaster recovery through PPP

Topology Disaster

(when two paths are mapped to one port), a disruption to existing SNA and

Recovery

 

Page 49
Image 49