4.Press Power [SK Toggle] until the desired frequency is displayed in the soft key command [9] (“Power” 50, 50L, 50H, or 100).

5.Press Locate [5] to return to Locate mode.

All export receivers default to 50 Hz.

To set the receiver to detect 60 Hz signals refer to Enabling/Disabling Frequencies section of this manual.

Passive

The receiver (without a 3M Dynatel Transmitter 2200) can be used to detect some CATV cables (31.5 KHz). (A horizontal-scan television NTSC must be turned on to generate this frequency.)

1.Press Locate [5]

2.Press Cable/Pipe [SK]

3.Press Freq [SK]

4.Press Pasv [SK Toggle]

5.Press Locate [5] to return to Locate mode.

Auxiliary

Auxiliary frequencies are signals generated from remote location transmitters, or frequency generating transmitters.

1.Press Locate [5]

2.Press Cable/Pipe [SK]

3.Press Freq [SK]

4.Press Aux [SK Toggle] until the desired frequency is displayed in the softkey command [9] (“Aux” 512, 560, 333 Hz, or user defined frequencies).

5.Press Locate [5] to return to Locate mode.

Locating in Directional Peak Mode

The following are instructions for locating a buried pipe or cable using the direct connect method and the directional peak (DirPk) mode. Other methods of connection and tracing features are explained in previous sections.

1.Insert the ground rod into the ground, perpendicular to the suspected target path.

22

78-8130-6151-8-E

Page 22
Image 22
3M 2273ME-iD, 2250ME-iD manual Locating in Directional Peak Mode, Passive, Auxiliary