3M 2250ME-iD, 2273ME-iD manual Induction Method, 78-8130-6151-8-E

Models: 2273ME 2250ME 2250ME-iD 2273ME-iD

1 52
Download 52 pages 28.1 Kb
Page 17
Image 17
Induction Method

Induction Method

If you cannot make a direct connection, or use the 3MDynatelDyna-Coupler clamp to apply a locating signal on the target, use the induction method. This method uses the internal coil of the transmitter to generate a magnetic field. This is the least preferred method of applying a signal on a target conductor because it can easily be picked up by other non-target conductors in the area. However, it is the preferred method of applying a signal to multiple cables/pipes in the same trench, and for the ‘two-man sweeping’ application.

1.Verify battery level of transmitter and remove any cables from the output jack.

2.Position the transmitter over the target facility with the hinge of the transmitter over and in line with the cable/pipe path.

3.Align the Induction Direction arrows on the transmitter with the target conductor.

4.Turn on the transmitter by pressing the Trace [T-3] key.

5.Press Trace [T-3] again to select 33 KHz or 133 KHz.

6.Select High Output level for the best signal-to-noise ratio.

7.Trace the signal path with the receiver using the Induction Peak mode.

The induction mode of the receiver is a mode in which the upper antenna of the receiver is tuned to minimize distortion from the magnetic field of the transmitter.

Note: The receiver must be at least 25 feet away from the transmitter to begin tracing the target path.

78-8130-6151-8-E

17

Page 17
Image 17
3M 2250ME-iD, 2273ME-iD manual Induction Method, 78-8130-6151-8-E